Siemens DB-ADPT Detector Base Adapter, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Installation Instructions DB ADPT Adapter Model DB ADPT detector base adapter inter Series 11 detectors with previously installed bases For Series 3 air duct detector models AD 3ILP and SA 3P use Series 11 Air Duct Kit AD 11UK which contains both and the required DA 304 air duct cover for 11 detectors replacing a detector with a different be aware that existing detector ac connected to the base or air duct that were compatible with the old may not be compatible with the new Always read the Installation Instruc accompanying the detector to determine and accessory compatibility DB 3S Bases Remove the existing detector from the DB 3S To install the DB ADPT adapter into the DB 3S align the notch in the outer flange of the to the raised surface on the outer ring of base Refer to Figure 1 Push the adapter into the base and rotate to engage the electrical connections adapter will automatically stop and lock into To make adapter DB 3S in the base use the Model DB LK a Series 11 detector instructions included with the detector If it becomes necessary to remove the push the adapter up into the base while the adapter counterclockwise Continue rotate counterclockwise until stop is reached pull downward to disengage from the base the DB LK lock is used disengage the mechanism prior to removing the adapter Series 3 Airduct Housings using the AD 11UK Duct Update Kit Remove the sensing compartment cover from the duct housing Remove the existing detector from the duct To install the adapter into the duct housing rotate adapter counterclockwise on the outer ring of base located in the duct housing until the drops into place Push the adapter down into the base and rotate to engage electrical connections The will automatically stop and lock into place a Series 11 detector instructions included with the detector new DA 304 sensing cover Tighten the cover snugly but so tightly as to warp cover and cause leakage the edges If it becomes necessary to remove the push the adapter down into the duct while rotating adapter counter Continue to rotate counterclockwise stop is reached Then pull upward to from the housing the DB ADPT to the DB 3S Base 1 Industry Inc Technologies Division Park NJ 315 094200 7 Canada Limited Technologies Division Kenview Boulevard Ontario L6T 5E4 Canada

Related Files