Specialized Detection Devices Series Detector Bases DB2 HR DB 11 and DB 11E AND ENGINEER SPECIFICATIONS Each detector base is compatible with Model series of conventional detectors All bases compatible with optional Model LK 11 detector locking kit Sheet Each detector base also functions with the Model series as well as Models OP921 OOH941 OOHC941 and HI921 detectors Model DB2 HR is also compatible with ASAtechnology detectors Model DB2 HR has backwards compatibility with Siemens Model intelligent detectors Models DB 11 and DB 11E mount on a 4 inch square or single gang electrical box Model DB 11 has plugs to cover the outer mounting screw holes Model DB2 HR mounts on a 4 double gang box Overview detector bases are low profile surface mounting used on various Siemens Fire Safety and addressable detectors DB2 HR which is a redesign of Model DB HR is with the standard addressable type of detectors as well as those detection devices operate with ASAtechnology Model DB2 HR is backward compatible with Siemens Model H series intelligent detectors and FACPs Model DB2 HR can also with Siemens 50 point addressable 252 point 504 point addressable and FireFinder fire systems A relay output from the fire detector for signaling other devices is provided by Model detector bases use screw clamp contacts for connections and self wiping contacts for better Further the bases can be used with the Model LK 11 detector locking kit which 50 detector locks and an installation tool to unauthorized removal of the detector head DB 11 and DB 11E are standard bases for Model and Model conventional as well as the Model addressable Model DB 11 has a 6 15.2 cm diameter and diameter for Model DB 11E is 4.5 inches 11.4 cm PRO Safety Security Products for infrastructure DB 11 DB 11E DB2 HR CSFM and NYC Fire Department Approved UL268 Listed ULC S529 Listed continued Models DB 11 and DB 11E mount on a 4 cm octagon or single gang box Model DB 11 has decorative plugs to cover the outer screw holes Model DB2 HR mounts on a double gang 4 inch cm square electrical box DB 11 The Model DB 11E base detector has a diameter dimension of 4.5 11.4 cm Diagram DB2 HR Series of Detector Bases Diagrams The illustration above is typical wiring for Models DB 11 and DB 11E using Models PE 11 PE 11T DT 11 OH121 OP121 and HI121 detectors The illustration above is typical wiring for Models DB 11 and DB 11E using Models FP 11 FPT 11 FS DP FS DPT and FS DT detectors The illustration above is typical wiring for Models DB 11 and DB 11E using Models HFP 11 Series and SFP 11 Series detectors The illustration above is typical wiring for Model DB2 HR for polarity insensitive detectors for Ordering Smaller Diameter Detector Base Relay Base for Intelligent Detector Housing Housing with Relay Surface Mount Base Surface Mount Base Canada S54370 F12 A1 base compatible with standard and advanced backwards compatible with Model intelligent detectors Thermal Detector Canada S54320 F8 A2 Multi Criteria Fire CO Detector with ASAtechnologyTM 135 57.2 Thermal Detector Thermal Heat Detector Addressable Multi Criteria Fire Detector Photoelectric Smoke Detector Multi Criteria Fire Detector with ASAtechnologyTM Base Locking Kit for Model detectors Intelligent Detector Intelligent Detector Canada Detector Detector Canada Addressable Detector Detector Detector Heat Detector Multi Sensor Smoke Detector Photoelectric Smoke Detector Photoelectric Smoke Detector Smoke Detector with 57.2 Thermal Sensor Thermal Detector Canada Detector Canada Package Canada CerberusTM PRO Industry Inc Building Technologies Div Fernwood Road Florham Park NJ 07932 973 593 2600 Fax 908 547 6877 www USA Siemens com Cerberus PRO The information contained in this data sheet document is intended only as a summary and subject to change without notice The devices described here have specific instruction sheets that various technical limitation and liability information of these instruction sheets and the General Product Warning and Limitations document also contains important information are provided with the product and are available from Manufacturer contained in these documents should be consulted before specifying or using the For further information or assistance concerning particular problems contact the Manufacturer Technologies Division Fire Safety in U S A 2012 Supersedes sheet dated 4 2012 1

Related Files