Disclaimer These are sample drawings and sequences Designers are responsible for the content for their particular projects 23 09 00 BUILDING AUTOMATION SYSTEM AND CONTROL FOR HVAC is supplemental language for a spec This is not an all inclusive spec This is language that is to be copied and pasted into an existing spec 1 GENERAL 2 PRODUCTS 3 BUILDING AUTOMATION SERVER HARDWARE a PC for the BAS Server database Provide the latest model of the nominal speed and memory for a commercial office grade PC from a named brand manufacturer requirements and accessories shall be UPS for 15 minute backup Intel 7 series or AMD equal processor speed minimum 6M cache Ram Dual Channel DDR3 SDRam at 1333MHz minimum R W CD and DVD Hard disk space 7200RPM Card with 512 MB RAM Ports Card key enhanced keyboard Mouse power strip a wide screen active matrix LCD flat panel type monitor that supports a minimum resolution of no less than 1920 1080 pixels Energy Star compliant 32 bit color The shall have a minimum of 21 inch visible area in diagonal measurement Separate shall be provided for color contrasts and brightness The screen shall be non reflective Provide a compatible inkjet or laser printer for alarms operator transactions and system Provide drivers Provide a color printer for printing of dynamic trend graph report Excel reports and any other screen displays Printer shall include as a minimum Okidata Microline or equivalent the BAS Server in a clean secure dry and temperature controlled environment server shall reside on the same BACnet IP protocol network as the System Controllers software licenses for interfacing to the BAS Load software configure and setup for the BAS system with the PC an operating system such asWindows 7 64 bit or Windows 2008 R2 These are sample drawings and sequences Designers are responsible for the content for their particular projects Provide the following application software licenses preloaded on the laptop for the MS Office Professional PC anywhere or terminal services Internet Explorer or equal MS Outlook Acrobat Reader CAD Viewer Micrographx Designer Set up an icon on desktop to take the Owner directly to the BAS system login page WORKSTATIONS HARDWARE Server hardware shall be of equal or better capability as that of Workstation and shall be as follows server as located on plans a minimum 16 GB RAM with hard drive of 320 GB available space with a video card 256 MB RAM capable of supporting a minimum of 1920 x 1080 resolution with a of 32 Bit color DVD RW Drive mouse and 101 key enhanced keyboard Server be a Windows 2008 R2 Server and shall include a dual core processor or better a monitor of flat panel type and shall support a minimum display resolution of no less 1920 x 1080 pixels The display shall have a minimum of 21 inch visible area in diagonal Separate controls shall be provided for color contrasts and brightness The screen be non reflective the Operator Workstations in a clean secure dry and temperature controlled software licenses for interfacing to the BAS Load software configure and setup for the BAS system the PC with an operating system such as Windows XP Vista or Windows Server or other operating systems compatible with the BAS software Provide the following application software licenses preloaded on the laptop for the MS Office Professional PC anywhere or terminal services Internet Explorer or equal MS Outlook Acrobat Reader CAD Viewer Set up an icon on the desktop to take the directly to the BAS system login page SERVER SOFTWARE connections Web based interface shall provide the same functionalities as those available at any workstation including operation and configuration capabilities Web server client licensing shall be from the same pool of client licenses available or client consoles or Windows desktop app clients connections ISP services as well as necessary firewalls or proxy servers shall be by the owner as required to support the Web access feature access to client server workstation configurations over the Intranet or Internet shall be via 3 client options Web Browser Client runs in a browser as a Full Trust client application These are sample drawings and sequences Designers are responsible for the content for their particular projects Installed Application Client runs as a fully installed software installation that lockdown desktop space and prevent the ability for the software to be minimized or by other applications Windows Desktop App An app that is downloaded to the client from the server PC that like an installed application and is automatically updated whenever new apps are at the server Graphics creation user shall be able to add delete modify system graphics from standard user without the need of any external or specialized tools HOSTED WEB BASED OPERATOR SOFTWARE BMS shall provide a Web based graphical interface that allows users to access the BMS via the Internet extranet or Intranet Functionality of web based clients shall provide the functionality and user interface provided by installed client consoles A Web server computer will be supplied The Web server shall use Microsoft IIS server with 2008 R2 Server or later and support browser access via Microsoft Internet Explorer All information exchanged over Internet shall be optionally encrypted and secure via SSL by Owner Web interfaces shall require the use of certificates to ensure safe secure connectivity to the to the Web interface may be password protected Users rights and privileges to points graphics may be the same as those assigned at any other workstation or may be from privileges at installed workstations Web interface shall not require modification or creation of HTML or ASP pages using an editor All graphics shall be available with the same look and functionality whether they displayed at an installed client console or in a browser Web based interface shall provide the same functionalities as those available at any other including operation and configuration capabilities Web server client licensing shall be from the same pool of client licenses available or client consoles or Windows desktop app clients connections ISP services as well as necessary firewalls or proxy servers shall be by the owner as required to support the Web access feature INTERFACE APPLICATION SOFTWARE Graphical User Interface GUI The GUI shall provide a completely interactive user interface must offer the following features as a minimum Trending Scheduling Memory to field devices These are sample drawings and sequences Designers are responsible for the content for their particular projects time Graphic Programs with auto refresh Name and Geographic Navigation methods changes of all adjustable object properties Adjustments Alarms and Events Usage Hyperlinks On line help menus BAS server and Operator Workstations shall meet the BACnet device profile of an Workstation Server B AWS and Operator Workstation B OWS and shall the following BACnet BIBBs Sharing Read Property Initiate Execute DS RP A B Sharing Read Property Multiple Initiate Execute DS RPM A B Sharing Write Property Initiate Execute DS WP A B Sharing Write Property Multiple Initiate DS WPM A Sharing COV Initiate DS COV A Sharing Management Management SCHED A and Modifying Trends Initiate T VMT A Trend Retrieval Initiate T ATR A Management Connection Establishment Initiate NM CE A and Event Notification Initiate AE N A and Event ACK Initiate AE ACK A and Event Summary Initiate AE ASUM A and Event Summary Initiate AE ESUM A and Event AE INFO A Ma

Related Files