Siemens Desigo Fire Safety System Fire-Alarm Enclosures and Equipment, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Sheet Safety Products Fire Safety System Enclosures and Equipment FHB2001 U1 R1 FHB2002 U1 R1 FHB2005 U1 R1 FHD2001 U2 R2 FHD2002 U2 R2 FHD2003 U2 R2 FHD2004 U1 FHD2006 U1 FHD2007 U2 R2 FHD2012 U1 FCM2022 U2 FCM2023 U2 VTO2001 U2 and VTO2004 U2 AND ENGINEER SPECIFICATIONS Used with various Siemens fire alarm panels FACPs One height unit 1HU two height 2HU three height unit 3HU Three height unit enclosures 3HU used only with Intelligent Voice Communications IVC panels Inner outer doors Blank plates for inner and outer doors Lens plate for outer door Hinged locking door provides easy access panel components Back boxes Available in either black or red Model FHB2005 U1 is used exclusively with IVC panels Knockouts for field wiring Overview Desigo fire alarm enclosures and their optional provide a complete set of hardware for all Desigo main system and remote cards and modules design the hardware not only offers precise for each Desigo addressable panel to be to a variety of applications but it also for future system upgrades in the enclosure series are back box and door removable mounting plates and clear lenses blank plates for use with the enclosure doors enclosures come with ground straps for the inner outer doors shield termination lugs grounding and tie wrap lances for securing wire Desigo two height unit enclosures which can also system back up batteries up to 33AH in are FM 3010 CSFM 7165 0067 0259 FDNY 6104 Approved Industry Inc Technologies Division Ground straps for the inner and outer doors termination lugs grounding lugs and lances are included UL 864 9th Edition Listed ULC Listed CSFM and NYC Fire Dept Approved Enclosure each Desigo panel one 1 red or black back box one 1 red or black outer door respectively inner door which is available in black specifically the system operating units Models FCM2018 and FCM2019 U2 back box supports the Fire Terminal board Model and optionally supports the Digital Communication Transmitter DACT Model one height unit enclosure 1HU is the smallest for the Desigo Fire Safety System The components comprise a complete 1HU One 1 1HU back box Model FHB2001 U1 R1 One 1 inner door Model FHD2004 U1 One 1 outer door Model FHD2001 U2 R2 One 1 clear lens Model FHD2006 U1 size 15 38.1 cm H 50.8 cm W 11 cm D Enclosures 6807 Overview continued FHB2001 U1 used on 1HU Enclosures enclosure is also a two height unit enclosure 2HU with Desigo Fire Safety addressable panels following components comprise a complete 2HU One 1 2HU back box Model FHB2002 U1 R1 One 1 or two 2 inner doors FHD2004 U1 or FHD2005 U1 One 1 outer door FHD2002 U2 R2 or FHD2003 U2 R2 One 1 or two 2 clear windows Model FHD2006 U1 One 1 window is installed for Model FHD2002 U2 R2 door and two 2 windows are required for FHD2003 U2 R2 size 28.5 72.4 cm H 50.8 cm W 15.2 cm D FHB2005 U1 used on 3HU Enclosures doors 2 types of inner doors are generally used with system enclosures Model FHD2004 U1 supports 1 operating unit Model FCM2018 U2 or with LED FCM2019 U2 one 1 Microphone Module one Switch Module or 1 one to four LED option modules Model FCM2023 U2 less than four LED option modules are used the module Model FCM2022 U2 covers module spaces in the inner door size 13.25 33.7 cm H 50.8 cm W FHB2002 U1 box used on 2HU Enclosures enclosure three height unit 3HU enclosure which can back up batteries up to 55AH is the largest available for Desigo panels and is used in IVC installations The following comprise a complete 3HU One 1 3HU back box Model FHB2005 U1 R1 Two 2 inner doors Models FHD2004 U1 Two 2 clear lenses Models FHD2006 U1 One 1 outer door One 1 blank plate An enclosure cover Model FHA2041 R1 is used to protect ventilation holes found at the top of red only 3HU Model FHB2005 R1 FHA2041 R1 prevents the FACP Its design and purpose meets New City Fire Department code for protecting uncovered FHD2007 U2 R2 FHD2009 U1 R1 holes on fire system enclosures size 42 106.7 cm H 53.3 cm W 19.7 cm D VTO2004 U2 FHD2004 U1 Module FCM2023 U2 Switch Model Model Model Model FHD2005 U1 is a solid blank plate to provide dead front protection Inner door Used with Remote Display Terminals there is an optional inner door that can be on Desigo 252 504 point addressable panels FHD2012 U1 mounts with Model FT201x series Display terminals Having a Model FHD2012 U1 door can help in preventing unauthorized access In compliance of ULC Canadian fire code the Model Inner Door must be ordered and used in Canada can see 6807C for more information Customers clear windows window Model FHD2006 U1 is a rugged Lexan and is mounted to the opening of the outer door size 10.25 26.04 cm H 43.2 cm W Industry Inc Technologies Division FHD2006 U1 Documentation Sheet Fire Safety overview Fire Safety addressable FIRE systems Fire Safety addressable IVC systems and Humidity Range are UL 864 9th Edition Listed for indoor dry within a temperature range of 120 2 to 32 3 0 2 and a relative of 93 2 at a temperature of 90 3 2 Data Desigo panel enclosures Door Back Box Material Colors Material Surface metal 0.062 or black metal 0.062 annealed Material clear Lexan Doors Door Box W x H x D Door W x H x D Inner W x H x D W x H x D 21.5 1.0 cm 9.8 cm 4.5 cm 13.3 0.7 cm 9.8 cm 6.4 cm 13.3 2.3 cm 33.8 cm 5.8 cm 8.3 0.13 cm 9.8 cm 4.5 cm Overview continued trim kits size enclosure has a trim kit available in black and The trim kit is used for flush mounting a Desigo enclosure Model FHA2035 U1 R1 is used for one height unit enclosure and FHA2036 U1 R1 is for the two height unit enclosure FHA2036 U1 Trim Kit IVC installations an optional 3HU trim kit can be to provide an aesthetically

Related Files