Siemens FB-Series, FC-Series, FJ-Series, FTS-Series and PCL Series - Remote Firefighters' Telephones and Accessories, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Fire Safety Modular Firefighters Telephones and FB Series FC Series FJ Series FTS Series PCL Series Architect Engineer Specifications Portable Firefighters Models PFT and Remote Telephone Jacks FJ 303 FJ 303SS FJ and FJ 304SS PCL Remote Telephone Models FTS FTS P FTS C FTS CL and FTS PCL Remote Telephone Station Models FB 300 FB Remote Telephone Station Model FC 300 UL864 CAN ULC S576 Product Overview firefighters telephones and accessories are available for use with the telephone system found on Desigo Fire Safety Modular system fire control panels FACPs These field mounted accessories are used in with the Firefighters Master Telephone Model FMT and the Zone Card Model TZC 8B located within the Desigo Fire Safety system enclosure Specifications Remote connection to the emergency telephone system on the Desigo Fire Modular system FACP can either be accomplished by plugging a portable telephone into a remote jack or lifting the handset on a remote station Either action will result in a signal from the main Desigo Fire Modular operator interface OI system operator can then manually activate the communication signal the connected telephone and Model FMT The system supports a of five 5 remote phones active simultaneously on a system without any of the signal Firefighters Telephones PFT and PFT P Portable Firefighters Telephones are for field connection to the emergency telephone Each phone consists of a rugged high impact plastic with a red coiled phone cord attached A 0.6 phone plug assembly is attached to the end of the phone for connection to the field mounted phone jacks PFT P includes a momentary spring action push to talk mounted in the handset This switch allows users to the button to activate the mouthpiece of the handset speaking to reduce background noise on the system Model PFT series Telephone Enclosure Telephone Enclosure Model MTE 2 includes the enclosure and door with lens and can be used to store up to six 6 Model PFT or PFT P telephone in a locked cabinet Firefighters typically take a handset from Model enclosure upon entering a building and can report back to the main system plugging into various jacks located throughout the building Temperature and Humidity Range are UL 864 9th Edition Listed for indoor dry locations within a range of 120 3 49 2 to 32 3 0 2 and a relative of 93 2 at a temperature of 90 3 32 2 Infrastructure Building Products Sheet 7345 usa siemens com fire Specifications continued Telephone Jacks Remote Telephone Jacks Models FJ 303 FJ 303SS FJ 304 and FJ 304SS are connected to the emergency tele system They are wired to the telephone zone circuits on the Telephone Zone Card Model TZC 8B located the Desigo Fire Safety Modular system enclosure There is no limit to the number of remote telephone jacks that be connected to a single telephone zone circuit remote telephone jacks are mounted to a single gang electrical box Models FJ 303 and FJ 303SS have flying connected to the phone jack while Models FJ 304 and FJ304SS have screw terminals Models FJ 303 and have a red baked enamel finish with a white silk screened telephone handset icon on them while Model and FJ 304SS have a brushed stainless steel finish with the handset icon Telephone Stations telephone stations for the emergency telephone system consist of a handset hook assembly a back box and a locked door with a breakable glass front Models FTS FTS P FTS C FTS CL FTS PCL Remote Telephone Stations consist of a handset similar to Model PFT a back plate and a cradle with magnetic latch mounted to the back plate and a connection cable from the handset to back plate suffix designates that a momentary push to talk button is included in the handset The suffix that an armored cable is used in place of a coiled cord between the handset and the back plate suffix designates that an integral light emitting diode LED is mounted to the back plate to indicate communication is established between the phone and Model FMT telephone stations must be used with either Model FB 300 or FB 301S remote telephone station box Model FB 300 is used for flush mount configurations and Model FB 301S is used for surface configurations The remote station back box assembly requires Model FC 300 cover with key door and breakable glass Additional replacement glass for Model FC 300 is available as Model FT Model FJ 304 station back box assembly requires Model FC 300 cover with key locked door and breakable Additional replacement glass for Model FC 300 is available as Model FT GLS Model Telephone Stations flush mount box H 7 W 3.5 D cm H x 17.8 cm W x 8.9 cm D surface mount box H x 8 W x 3.62 D cm H 20.3 cm W 9.2 cm D door H x 8 W cm H 20.3 cm W Phone Jacks 303SS 304 304SS H x 2.75 W cm H x 7 cm W Mounts in a single gang box Storage Enclosure MTE 2 H x 24.1 W x 3.3 D cm H x 61.3 cm W x 8.4 cm Infrastructure Building Products usa siemens com fire for Ordering TYPE back box for Telephone Station back box for Telephone Station door Telephone Station Remote Phone Jack Red Phone Jack stainless steel Mounted Remote Phone Jack mounted Phone Jack and stainless steel Telephone Station Telephone Station armored cable Telephone Station armored cable LED Telephone Station with button Telephone Station w push to talk button cable and LED Glass Telephone Station Storage Enclosure handsets Firefighters Telephone Firefighters Telephone push to talk button Canada order English Glass For FC 300 back box for Telephone Station

Related Files