Siemens FC2025 and FC2050 252-Point and 504-Point Addressable Fire Alarm Control Panel (for Canada), Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Data Sheet Safety Security Products Fire Safety System and 504 Point Addressable Fire Alarm Control Panel FC2025 and FC2050 Addressable fire alarm control panel FACP intended for AND ENGINEER SPECIFICATIONS building applications Comprised of the following system components Operating units Periphery boards Power supplies System enclosures System features Supports 252 to 504 addressable devices Model FC2025 one 1 to four 4 B one 1 to two 2 A Model FC2050 one 1 to eight 8 B one 1 to four 4 A Includes one 1 A or two 2 B notification appliance circuits NACs Releasing module supports activation of releasing valves in pre deluge systems agent release Resettable and non resettable 24VDC nominal auxiliary power Digital alarm communication transmitter DACT Connectivity to a leased line city tie module Fast and easy set up with auto configuration feature ULC Listed CSFM NYC Fire Department Approved Overview Desigo Fire Safety 252 point Model FC2025 FC2050 addressable FACP is designed to the fire protection needs of mid size buildings advanced panel offers features typically required mid size buildings in a package that is easy to install competitively priced Additionally Models and FC2050 are networkable allowing the to fulfill the growing fire protection needs of building The programming software for the 252 fire systems is held in flash electrically programmable read only memory EEPROM following Desigo Fire Safety system components used in the 252 point 504 point FACP Operating units Power supplies Periphery boards System enclosures options are available to meet specific needs of customer Models FC2025 and FC2050 are FM CSFM 7165 0067 0259 and FDNY 6104 two height unit with one 1 window Interface Unit Operating Interface Unit Model FCM2018 U2 or FCM2035 U2 functions as the operating interface central microprocessor for Models FC2025 FC2050 operating interface unit provides multi use for each end user to efficiently to quickly control the NACs of the FACP and to a manual reset of the respective system Detailed about the nature and location of the events also be displayed via a backlit 5.1 cm 12.1 cm screen and the four way navigation push button at top of the FACP Boards periphery boards Models FCI2016 U1 and FCI2017 serve as the main operating components for the 252 504 point FACP Each module operates and monitors identity as well as controls the signaling line that communicate with smoke detectors and field devices i e FDnet Panel for mid size buildings 6815C Canada Limited continued Supplies functions are supported by the 170W Model FP2011 or 300W Model FP2012 U1 power supplies which the need for external power supplies Models FP2011 U1 and FP2012 U1 provide 24VDC nominal power for normal operation to FC2025 and FC2050 Both power supplies are and regulated Model FP2011 U1 is rated at 6.5 while the rating of Model FP2012 U1 is 11.5A 170 Watt power supply incorporates a 4.0A non slow blow fuse on the primary input and a built in AC line filter for surge and noise Model FP2011 U1 mounts in the panel and there are no serviceable Desigo Fire parts to be maintained 300 Watt power supply incorporates two 2 6.3A non resettable slow blow fuses on the input and includes a built in AC line filter for and noise suppression Model FP2012 U1 mounts the panel enclosure and there are no serviceable Fire Safety parts to be maintained Enclosures Desigo fire alarm enclosures and their accessories a complete set of hardware for mounting all main system and remote terminal cards and hardware allows this Desigo system to be configured a variety of applications as well as for future system Included in the enclosure series are back box door sets removable mounting plates and clear and blank plates for use with the enclosure doors enclosures come with ground straps for the inner and doors shield termination lugs grounding lugs and lances for securing wire All Desigo two height enclosures can also mount system back up batteries to 33AH in capacity FC2025 and FC2050 utilize a two height unit The following components comprise a two height unit enclosure One 1 back box Model FHB2002 U1 R1 One 1 or two 2 inner doors FHD2004 U1 or FHD2005 U1 One 1 outer door FHD2002 U2 R2 or FHD2003 U2 R2 One 1 or two 2 clear windows Model FHD2006 U1 One 1 window is installed for Model FHD2002 U2 outer door and two 2 windows are required for FHD2003 U2 R2 approximate size for each two height unit enclosure 70cm 27.5 high 54.6cm 21.5 wide and 5.75 deep The weight without any attached is approximately 2858g 6.3 Lbs Canada Limited the two height unit enclosure supports the components Enclosure trim kit for flush mounting Battery bracket to comply with seismic certification DIN rail kit provides connection between internal system and field wiring Expansion Module notification appliance circuit NAC expansion Model FCI2011 U1 provides additional NACs to 252 504 point panel one 1 A or two 2 B NACs NAC is rated at 3 Amps Each NAC expansion is monitored for open line and short circuit Alarm Communication Transmitter DACT Digital Alarm Communicator Transmitter DACT is to provide communication between Models and FC2050 and with either a central or remote station Model FCA2015 U1 module mounts directly on the enclosure and connects to the periphery boards DACT enables remote transmission of alarms and via a public telephone line Module releasing module Model XCI2001 U1 supports of releasing valves in pre action deluge including double interlock pre action systems Sinorix Engineered Fire Suppression Systems can be event controlled or performed by manual pull stations The releasing module installed on the periphery board and supports B circuits installed on Models FC2025 FC2050 the module contains an integral manual switch for releasing circuits This essential protects the releasing circuits from accidental during maintenance City Tie Module FCI2020 U1 which is installed on the periphery of the FACP provides a local energy output for call box connection and gives a reverse output for leased line connection used for connection to a municipal call box the function supports Alarm event transmission used for leased line connection the module two 2 leased telephone lines for transmitting Trouble and Supervisory events continued Module SafeDLINK network module Model FN2001 U1 is to network up to 16 FACPs or fire terminals via the system bus Model FN2001 U1 is plugged into Operating Unit Models FCM2018 U2 R2 and R2 FN2001 U1 which connects to system input bus has ground fault monitoring as well as an degrade mode feature Redundant is accomplished with one 1 network per panel Simple Loop Trouble There is isolation between the system bus and the Display Terminals Remote Display Terminals Models FT2014 U2 R2 FT2015 U2 R2 are remote annunciators that show existing status of Models FC2025 FC2050 diodes LEDs will illuminate for any Alarm Supervisory and Trouble Desigo system A 5.1 cm 12.1 cm LCD screen will give of the event in alphanumeric form The display can be scrolled via the four way navigation to reveal additional events FT2014 is a disp

Related Files