Siemens FCA2018-U1 (with Model FCA2016-U1), Cerberus PRO Remote Peripheral Module (with RS-485), Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fca2018-u1-with-model-fca2016-u1-cerberus-pro-remote-peripheral-module-with-rs-485-data-sheet-8603154279.pdf |
---|---|
Type | |
Size | 1.25 MB |
Downloads |
Text Preview
Data Sheet PRO Peripheral Module with RS interface FCA2018 U1 with Model FCA2016 U1 AND ENGINEER SPECIFICATIONS FCA2016 U1 FCA2018 U1 Provides connection to the external event Model PAL 1 Provides an interface to remote printers Two 2 serial ports and one 1 parallel Mounts remotely from a Cerberus PRO Alarm Control Panel FACP Provided in its own enclosure Supervised intelligent module Supports B Style 4 or A 6 wiring Fast installation with IN OUT screw using 12 to 18 AWG wire Built in transient protection Downloadable module firmware Built in flash electrically erasable Dual standardized RS interface that is on 252 504 point control panels RS module provides communication to FCA2018 U1 for managing and Model PAL 1 Supports B Style 4 and A 6 wiring configurations Up to eight 8 devices on the RS Fire Protocol UFP network Electrical isolation between the RS and a Cerberus PRO FACP Ground fault monitoring read only memory EEPROM Plain decimal addressing UL 864 9th Edition Listed ULC Listed FM CSFM NYC Fire Dept Approved Overview Remote Peripheral Module Model FCA2018 U1 a means of connecting a Cerberus PRO system to parallel printer for creating a hard copy of system status configuration reports This supervised intelligent contains built in transient protection and plain addressing FCA2018 U1 is remotely connected to the Model RS communication bus from any PRO system enclosure Model FCA2018 U1 uses B Style 4 or Class A Style 6 wiring and provides 2 RS serial ports and a single parallel port that connection to the parallel printer Model PAL 1 Model PAL 1 is used with the remote peripheral Model FCA2018 U1 supervises the printer for ON Line POWER ON PAPER OUT PAPER JAM and wiring conditions per UL for NFPA 72 requirement for systems report printing is generated at the operating unit FCM20 series on the main Cerberus PRO system Safety Products PRO for infrastructure UL 864 9th Edition Listed ULC Listed FM CSFM NYC Fire Dept Approved For PAL 1 connectivity with Remote Peripheral on Cerberus PRO 252 point and 504 point systems a Model FCA2016 U1 RS interface must be ordered used FCA2018 U1 has necessary mounting flanges to the module to be mounted unobtrusively under a or behind a desk Model FCA2018 U1 runs on 24VDC nominal power and this source for can be provided from the auxiliary power on the Cerberus PRO system enclosure from other UL Listed 24VDC power sources is acceptable Model FCA2018 U1 has screw terminals of supporting a 12 to 18 American Wire Gauge configuration 252 point addressable system Model FC922 and 504 point addressable system Model FC924 require a RS interface Model FCA2016 U1 provide to the remote peripheral module FCA2018 U1 and FCA2016 U1 are FM 3010 6104 and CSFM 7165 0067 0259 Approved Peripheral Module with RS interface for Ordering S54400 A65 A1 Remote Peripheral Module S54400 A39 A1 RS interface Printer and Humidity Range are UL 864 9th Edition Listed for indoor dry within a temperature range of 120 3 2 to 32 3 0 2 and a relative of 93 2 at a temperature of 90 3 2 Documentation Printer Display Terminals Cerberus PRO System Cerberus PRO System Cerberus PRO System Cerberus PRO System markets Cerberus PRO System markets Sheet Data Receiving Transmitting mode of participants wire length peak peak 8 maximum feet max twisted pair wiring Interface Design Admissible Terminal Block screw terminal to 18 cable Wire Gauge AWG Interface connection FCA2018 U1 W x H x D FCA2018 U1 FCA2016 U1 W x H x D FCA2016 U1 150mA 6.75 2.5 cm x 17.1 cm x 6.4 cm Lbs 794g 0.6 2.76 cm x 1.5 cm x 7 cm Lbs 20g Cerberus PRO Industry Inc Building Technologies Div Fernwood Road Florham Park NJ 07932 973 593 2600 Fax 908 547 6877 www USA Siemens com Cerberus PRO The information contained in this data sheet document is intended only as a summary and subject to change without notice The devices described here have specific instruction that cover various technical limitation and liability information of these instruction sheets and the General Product Warning and Limitations which also contains important information are provided with the product and available from the Manufacturer contained in these documents should be consulted before specifying or using the For further information or assistance contact the Manufacturer Technologies Division Fire Safety in U S A 2016 Supersedes sheet dated 8 2013 4