Siemens FCI2016-U1 and FCI2017-U1 System Periphery Boards, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fci2016-u1-and-fci2017-u1-system-periphery-boards-data-sheet-7694025138.pdf |
---|---|
Type | |
Size | 1.08 MB |
Downloads |
Text Preview
Cerberus PRO Fire Safety Periphery Boards FCI2016 U1 and FCI2017 U1 AND ENGINEER SPECIFICATIONS Sheet Used with Cerberus PRO panels Model FCI2016 U1 is used with Model FC922 panel Model FCI2017 U1 is used with Model FC924 panel Maximum 252 point device addresses per loop card Up to 252 addresses are used with Model FCI2016 U1 Up to 504 addresses are used with Model FCI2017 U1 Model FCI2017 U1 has two 2 integrated loop cards A Loop B with EMC surge protection for eight Style 4 or four 4 Style 6 7 loops Model FCI2016 U1 has one 1 integrated loop card A Loop B with EMC surge protection for four 4 4 or two 2 Style 6 7 loops NAC connection for one 1 Class A or two 2 B functions 3 Amps max for NAC for synchronization and alarms Two 2 plugs for optional extensions Leased line city tie module Notification Appliance Circuit NAC Expansion Module or Module Additional peripheral data bus connection for or digital alarm communication transmitter modules Field wiring configuration via removable blocks Overview periphery boards Models FCI2016 U1 and are the main components for operation the Cerberus PRO panels Models FC922 and Both models are FM 3010 CSFM 7165 and FDNY 6104 Approved module operates and monitors input device as well as controls the signaling line circuits communicate with smoke detectors and other devices i e C NET All functions are by the power supplies of either Model or Model FP2012 U1 FP2011 U1 provides regulated 24VDC 6 amps max while Model FP2012 U1 regulated 24VDC nominal 11.5 Amps to the Models FC922 and FC924 Cerberus systems PRO Safety Security Products for infrastructure board for 252 pt board for 504 pt PRO Fire Safety system PRO Fire Safety system Degrade mode functions Four 4 configurable relay outputs Battery charger included Auxiliary output 24VDC nominal 1.5 Amps UL 864 9th Edition Listed ULC Listed CSFM and NYC Fire Dept Approved periphery board is equipped with two 2 B Style Y or 1 Class A Z NAC providing 24VDC nominal up to 3A circuit of audible visual notification appliances periphery board has an integrated C NET loop with built in EMI surge protection thus automatic devices to be installed and for B or A circuit operation FCI2016 U1 supports 1 one to four 4 circuits or supports 1 one to two 2 A that can supervise and control up to 252 Model FCI2017 U1 supports 1 one to eight B circuits or supports 1 one to four 4 A circuits that can supervise and control up to devices Boards Data Operating Current Voltage Regulated 24VDC nominal with FP2011 U1 with FP2012 U1 Voltage 24VDC nominal 6A for Model FP2011 U1 for Model FP2012 U1 Power Operating Voltage Regulated 24VDC 1.5A max C 5A max 5A max Voltage of Integrated Cards max 1 for Model FCI2016 U1 2 for Model FCI2017 U1 max max with FCI2016 U1 max with FCI2017 U1 2 A loops or 4 B loops for 4 A loops or 8 B loops for variants are possible Types types recommended twisted detailed specifications IOM A6V10337045 For Ground fault Short circuit Open loop Outputs C NET terminal blocks size W x H x D 22 AWG Wire Gauge x 11.25 x 0.125 cm x 29 cm x 0.32 cm Lbs 20g Overview continued following devices work with the C NET loop Model devices Model devices Model devices Monitor module periphery board has a built in battery charger that the status of the battery and provides 4 modes of operation trickle bulk over and float The charger also contains an power transfer circuit that switches the to standby batteries during reduction and loss of primary AC power sources automatically back to AC power when normal power is restored The battery connects to Model FCI2016 U1 FCI2017 U1 The battery connects directly to each board periphery boards mount directly on the backboxes of the Model FC922 and FC922 Cerberus PRO panels Models FCI2017 U1 provide two 2 parallel powered short circuit protected regulated 24VDC 1.5A max that power to external devices or modules The periphery boards also include a Bell terminal connection allowing the NACs follow external coded signals periphery boards support connection to the optional modules City Tie Leased Line Notification Appliance Circuit NAC Expansion Module Releasing Module Digital Alarm Communicator Transmitter DACT Light emitting diode LED module FCI2016 U1 and FCI2017 U1 contain 4 C relays and defaults to the system events System Alarm Supervisory Trouble Programmable system firmware is also resident in flash erasable programmable read only EEPROM and can be upgraded by upload eliminating the need for chips Industry Inc Technologies Division and Humidity Range FCI2016 U1 and FCI2017 U1 are UL 864 9th Listed for operation within the temperature of 32 to 120 0 to 49 and a relative of 93 2 at a temperature of 90 3 Documentation Sheet Number for Ordering S54400 A55 A1 S54400 A56 A1 Board for the FC922 Cerberus PRO panel Board for the FC924 Cerberus PRO panel Industry Inc Technologies Division PRO CerberusTM PRO Industry Inc Building Technologies Div Fernwood Road Florham Park NJ 07932 973 593 2600 Fax 908 547 6877 www USA Siemens com Cerberus PRO The information contained in this data sheet document is intended only as a summary and is to change without notice The devices described here have specific instruction sheets that cover technical limitation and liability information of these instruction sheets and the General Product Warning and Limitations document also contains important information are provided with the product and are available from Manufacturer contained in these documents should be consulted before specifying or using the product further information or assistance concerning particular problems contact the Manufacturer 2013 Supersedes sheet dated 4 2012 2 Technologies Division Fire Safety in U S A