Siemens FCI2016-U1 FCI2017-U1 System Periphery Boards, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fci2016-u1-fci2017-u1-system-periphery-boards-data-sheet-8314625907.pdf |
---|---|
Type | |
Size | 1.08 MB |
Downloads |
Text Preview
s Fire Safety System Sheet Safety Security Products AND ENGINEER SPECIFICATIONS Periphery Boards FCI2016 U1 and FCI2017 U1 Used with Desigo panels Model FCI2016 U1 is used with Model FC2025 panel Model FCI2017 U1 is used with Model FC2050 panel Maximum 252 point device addresses per loop card Up to 252 addresses are used with Model FCI2016 U1 Up to 504 addresses are used with Model FCI2017 U1 Model FCI2017 U1 has two 2 integrated loop cards A Loop B with EMC surge protection for eight Style 4 or four 4 Style 6 7 loops Model FCI2016 U1 has one 1 integrated loop card A Loop B with EMC surge protection for four Style 4 or two 2 Style 6 7 loops NAC connection for one 1 Class A or two 2 B functions 3 Amp max per NAC for synchronization and alarms Two 2 plugs for optional extensions Leased line city tie module Notification Appliance Circuit NAC Expansion Module Releasing Module blocks modules Additional peripheral data bus connection for LED or digital alarm communication transmitter Field wiring connection via removable Overview periphery boards Models FCI2016 U1 and are the main components for operation the Desigo panels Models FC2025 and FC2050 module which is FM 3010 CSFM 7165 and FDNY 6104 Approved operates monitors input device identity as well as the signaling line circuits that with smoke detectors and other field i e FDnet All functions are supported by power supplies of either Model FP2011 U1 or FP2012 U1 FP2011 U1 provides regulated 24VDC 6 amps max while Model FP2012 U1 regulated 24VDC nominal 11.5 amps max to Models FC2025 and FC2050 Desigo systems Industry Inc Technologies Division board for 252 pt Fire Safety system board for 504 pt Fire Safety system Degrade mode functions Four 4 configurable relay outputs Battery charger included Auxiliary output 24VDC nominal 1.5 Amps CSFM and NYC Fire Department Approved UL 864 9th Edition Listed ULC Listed periphery board is equipped with two 2 B Style Y or 1 Class A Z NAC providing 24VDC nominal up to 3A per of audible visual notification appliances FCI2016 U1 FCI2017 U1 have integrated loop circuit with built in EMI surge protection allows automatic devices to be installed and for B or A circuit operation FCI2016 U1 supports 1 one to four 4 B circuits or supports 1 one to two 2 A circuits that can supervise and control up to devices Model FCI2017 U1 supports 1 one 8 B circuits or supports 1 one to 4 A circuits that can supervise and up to 504 devices Boards 6802 Data Voltage Regulated 24VDC nominal Operating Current with FP2011 U1 with FP2012 U1 Voltage 24VDC nominal for Model FP2011 U1 for Model FP2012 U1 Voltage Regulated 24VDC 1.5A max C 5A max 5A max Voltage of Integrated Cards max 1 for Model FCI2016 U1 2 for Model FCI2017 U1 max max with FCI2016 U1 max with FCI2017 U1 2 A loops or 4 B loops for 4 A loops or 8 B loops for variants are possible Types types recommended twisted detailed specifications IOM A6V10337045 For Ground fault Short circuit Open loop and terminal blocks size W x H x D 22 AWG Wire Gauge x 11.25 x 0.125 cm x 29 cm x 0.32 cm Lbs 20g continued following devices work with the FDnet loop Model devices Model devices Model devices Monitor module periphery board has a built in battery charger that the status of the battery and provides 4 modes of operation trickle bulk over and float The charger also contains an power transfer circuit that switches the to standby batteries during reduction and or of primary AC power sources automatically back to AC power when normal power is restored The battery connects to Model FCI2016 U1 FCI2017 U1 module periphery boards mount directly on the back boxes of the Model FC2025 and FC2025 Desigo panels Models FCI2016 FCI2017 U1 provide two 2 parallel auxiliary short circuit protected connections 24VDC 1.5A max that supply power external devices or modules The system boards also include a Bell Follower connection allowing the NACs to follow signals periphery boards support connection to the optional modules City Tie Leased Line NAC Expansion Module Releasing Module Digital Alarm Communicator Transmitter DACT Light emitting diode LED module FCI2016 U1 and FCI2017 U1 contain four C relays and defaults to the following events System Alarm Supervisory Trouble Programmable system firmware is also resident in flash erasable programmable read only EEPROM and can be upgraded by upload eliminating the need for chips Industry Inc Technologies Division and Humidity Range FCI2016 U1 and FCI2017 U1 are approved operation within the temperature range of to 120 0 to 49 and a relative of 93 2 at a temperature of 32 2 Documentation Sheet Number for Ordering S54400 A55 A1 S54400 A56 A1 Board for the Model Desigo panel Board for the Model Desigo panel Industry Inc Technologies Division This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www USA Siemens com Desigo Fire Safety in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2013 sheet dated 4 12 2