Siemens FCI2020-U1 Leased line city tie module, Mounting Installation
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fci2020-u1-leased-line-city-tie-module-mounting-installation-3842759061.pdf |
---|---|
Type | |
Size | 1006.21 KB |
Downloads |
Text Preview
FCI2020 U1 line city tie module Industry Inc Technologies Division notice notice specifications and availability subject to change without notice 2012 2014 Copyright by Siemens Industry Inc reproduction dissemination and or editing of this document as well as of its contents and communication thereof to others without express are prohibited Offenders will be held liable for payment of damages All created by patent grant or registration of a utility model or design patent are by Industry Inc Technologies Division Fernwood Road Park NJ 07932 1 973 593 2600 2014 05 26 ID A6V10334256 b en Industry Inc Technologies Division of contents Line City Tie module FCI2020 5 5 6 installation 7 8 10 Output 1 Leased line or City tie 11 Output 2 Leased line 11 wiring 11 data 12 Statement 13 Industry Inc Technologies Division Line City Tie module FCI2020 Industry Inc Technologies Division Line City Tie module FCI2020 Leased Line City Tie module FCI2020 Description Leased Line City Tie module FCI2020 is an optional module that can be for leased line or city tie functions It is installed on the periphery board for to a remote monitoring station or city municipal tie The periphery board and supervises the leased line city tie module leased line function supports two leased telephone lines for transmitting alarms and trouble events city tie function supports direct connection to city tie installations Supervised city tie connection open circuit only Direct connection to city tie or leased line Supports local energy connection Replaceable fuses Industry Inc Technologies Division Line City Tie module FCI2020 Installation leased line city tie module FCI2020 is plugged into the periphery board and is down to the back box the leased line city tie module board 250p or periphery board 500p fixing screw line city tie module threaded sleeve on back box in periphery board wiring terminal connections steps Plug the leased line city tie module 3 into connector X902 of the periphery Fasten the module to the threaded sleeves 4 in the back box using the two 1 2 Configure the module properties with the Engineering tool set Industry Inc Technologies Division Line City Tie module FCI2020 installation FC901 installation Secure the city tie to the main board using the two provided 4 32 x 3 8 screws A 4 screws tie Connect the city tie cable between city module and main board Industry Inc Technologies Division Line City Tie module FCI2020 left to right 1 to 4 T1 Output 2 to T2 Output 1 to T3 A City tie cabling Views circuit board view for FCI2020 Industry Inc Technologies Division 1 Line City Tie module FCI2020 2 Leased line supervisory connection needed if configured as city tie 1 Leased line trouble leased line alarm city tie connection depending configuration for output 2 T1 25 A 250 V SLO BLO for output 2 T1 25 A 250 V SLO BLO for output 1 T1 25 A 250 V SLO BLO for output 1 T1 25 A 250 V SLO BLO Replace with UL approved fuses only SLO BLO 1,25 A 250 V Littelfuse Inc No 02151.25P Schurter AG No SPT0001.2505 Industry Inc Technologies Division Line City Tie module FCI2020 Wiring line wiring LINE LINE All wiring must be in accordance with article 760 of NEC or local building code Leased line circuits are not supervised Polarity shown in active state No signal polarity inversion Ground faults detected at 0.1 The circuit resistance must be between 2 and 5 k for each switching Tie wiring USED Tie All wiring must be in accordance with article 760 of NEC or local building code City tie connection is supervised for open circuit only Ground faults detected at 0.1 for X2 or X3 Polarity shown in supervision state The circuit resistance must not exceed 22.5 Industry Inc Technologies Division Line City Tie module FCI2020 wiring X3 Output 1 Leased line or City tie City tie module X3 transmits the alarm status Leased line module X3 transmits alarm and trouble messages X2 Output 2 Leased line output 2 is only used for leased line supervisory Not used when module is as a city tie output when activated output when activated size 12 AWG output when activated output when activated size 12 AWG FC901 wiring provides one city tie or one leased line to connect with local energy Supervised Power Limited Industry Inc Technologies Division Line City Tie module FCI2020 data Technical data for leased line city tie module input voltage currents Leased line normal operation standby Leased line alarm current Leased line supervised City tie normal operation standby City tie alarm current condition circuit supervision current operation resistance during alarm shorted current operation operation operation resistance shorted current operation condition resistance shorted current 24 V mA DC 24 V mA DC 24 V mA DC 24 V mA DC 24 V mA DC 24 V 24 V open mA 24 V open 22.5 mA 24 V open 0 V 24 V open k mA 24 V open 24 V open k mA 1 CT City Tie 1 LL Leased Line 2 LL Leased Line Industry Inc Technologies Division Statement FCC Statement and usage of equipment is not in accordance with instructions manual of radio frequency energy to radio communications Read the following information and use equipment in accordance with instructions manual equipment generates uses and can radiate radio frequency energy and if not and used in accordance with the instructions manual may cause interference radio communications has been tested and found to comply with the limits for a Class A computing device to Part 15 of FCC Rules which are designed to provide reasonable protection such interferen