Siemens FCM-6S LCM-8S SCM-8S Control Module LED Control Module Switch Control Module CAN Sounder Board, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Installation Instructions FCM 6S LCM 8S SCM 8S Module LED Control Module Switch Control Module CSB Sounder Board SIEMENS Models FCM 6S LCM 8S and SCM 8S similar in appearance and identical in installation with the suffix are gray in color SIEMENS Model FCM 6S Control Module 1 contains six sets of three pushbutton and their corresponding LEDs The ON and switches both have one bi color red green while the OFF switch has one bi color and one LED The functions of the switches and LEDs programmed using the Zeus Tool Refer to the Quick Start Guide P N 315 033875 All LEDs be programmed ON OFF or FLASHING The is designed for general control requiring ON operation SIEMENS Model LCM 8S LED Control Module 2 contains eight pairs of LEDs Each pair one bi color red green and one yellow LED functions of the LEDs are programmed using the Tool Refer to the Zeus Quick Start Guide P N All LEDs can be programmed ON OFF FLASHING These LEDs are used for fire system annunciation The SIEMENS Model SCM 8S Switch Control Figure 3 contains eight switches and eight of LEDs Each pair contains one bi color red and one yellow LED The functions of the and LEDs are programmed using the Zeus Refer to the Zeus Quick Start Guide P N 315 All LEDs can be programmed ON OFF or The SCM is used for manual control of fire system 1 Control Module 2 LED Control 3 Switch Control 315 035800 2 Industry Inc Technologies Division SIEMENS Model CSB CAN Sounder Board 500 033130 is an optional module that can be separately It contains a sounder buzzer that be used with the SCM 8S or FCM 6S to provide feedback to indicate that a switch closed and communication was successful The requires no programming modules mount on the inner door of an enclosure 4 Sounder Board Controls and Indicators The FCM contains six sets of three pushbutton switches and their corresponding Pressing any of the six ON OFF or AUTO switches generates a unique CAN on the bus to the NIC that indicates which switch was pressed A CAN from the NIC to the FCM produces a preprogrammed output to the corre LED ON FLASHING or OFF An open collector is provided for connection the CAN Sounder Board CSB a separate audio module The CSB provides an feedback to indicate that the switch closed properly and that communication the FCM and NIC was successful Controls and Indicators The LCM contains eight pairs of LEDs A CAN message from the NIC to the LCM a preprogrammed output to any of the corresponding LEDs ON FLASH or OFF Controls and Indicators The SCM contains eight switches and eight pairs of LEDs Each switch is associated a pair of LEDs Pressing of any of the eight switches generates a unique CAN on the bus to the NIC that indicates which switch was pressed A CAN from the NIC to the SCM produces a preprogrammed output to the LED ON FLASHING or OFF An open collector is provided for to the CAN Sounder Board CSB a separate audio module The CSB an audible feedback to indicate that the switch closed properly and that between the SCM and NIC was successful Controls and Indicators The CSB contains a sounder buzzer that sounds when any switch on an FCM or is pressed Only one CSB is required for audible feedback more can be to increase the volume if needed the board address for each FCM LCM SCM using both of the ten position rotary located on the back of the board See Figure 5 Each of these addresses be a sub address of the NIC and must be the same as the addresses assigned the Zeus Programming Tool The CSB does not require address setting setting the address label each switch or LED When viewed from the front of the FCM LCM SCM the labels are on the left and the control switches and are on the right to the Zeus configuration for the address of each module and its functions the label strip from its slot and type or print a brief function for each switch completing the label strip insert in back into its slot See Figure 6 Industry Inc Technologies Division 315 035800 2 8 8 SWITCHES 5 LCM 8S SCM 8S Address Switches And Connections 6 A Label Into The Back Of The FCM 6S Sounder Board CSB is normally positioned at the last FCM LCM or SCM If desired multiple can be installed The CSB mounts on the stud of the FCM LCM SCM module it connects to the position of the CSB This is normally at the last FCM LCM SCM module necessary remove nut from stud of FCM LCM SCM where CSB is to be mounting hole on the CSB over stud with nut supplied with FCM LCM SCM to Figure 7 ELECTRICAL POWER prior to working on equipment FCM LCM SCM module is a node in the CAN bus FCM LCM SCM connects through the CC 5 CC 2 CAN bus via a cable to the NIC or to another FCM LCM SCM module to 99 FCM LCM SCM modules in any combination can be connected the CAN bus of each NIC FCM LCM SCM CSB module is shipped with one CCS cable Industry Inc Technologies Division 315 035800 2 TERMINATOR C24235 A1 K2 WITH DAC NET 0 0 0 0 0 0 0 0 CC 5 CC 2 P3 CCL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CCS 8 Wiring For FCM 6S LCM 8S SCM 8S And CSB connections for FCM LCM SCM CSB modules are shown in the table and in Figure 8 Industry Inc Technologies Division 315 035800 2 PSC 12 C TO 599 634214 1 2 c c CC 2 CC 2 1 2 8 Power For FCM 6S LCM 8S SCM 8S Modules CAN bus requires a 120S resistance at each end of the loop Refer to the Installation Instructions P N 1A24205 A334 B839 for details about CAN RATINGS Industry Inc Technologies Division 315 035800 2 Industry Inc Technologies Division 315 035800 2 Industry Inc Technologies Division

Related Files