Siemens FDCIO422 4-Input 4-Output Interface Module (for Canada), Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fdcio422-4-input-4-output-interface-module-for-canada-data-sheet-6532941078.pdf |
---|---|
Type | |
Size | 1.41 MB |
Downloads |
Text Preview
s Sheet Safety Products Peripheral Devices AND ENGINEER SPECIFICATIONS 4 Output Interface Module FDCIO422 Four 4 inputs four 4 outputs via one 1 address Input lines can be supervised for open short and ground fault conditions Light emitting diode LED display of input output status Supports A and B input circuit wiring Polarity insensitive with SureWire technology Microprocessor controlled signal evaluation Two wire installation per addressable loop Power supply via FCnet module Communication via FDnet Individual addressing Four 4 AC rated DC rated outputs Mounts in one 1 electrical back box Optional 12 cm and 12.7 cm square back boxes FDCIO422 front plate included Electronic address programming is easy and dependable Model DPU programs and verifies address of the device as well as performs test functionality Easy front end access to programming port and wiring terminals Restriction of Hazardous Substances RoHS compliant ULC Listed Overview four 4 input four 4 output interface module FDCIO422 from Siemens Fire Safety is designed provide the means for interfacing direct shorting devices the Device Loop Card Model DLC FireFinder XLS as as the Models FC2025 and FC2050 fire alarm control FACPs FDCIO422 which contains microcomputer chip technology and is polarity insensitive achieves state of an device through its highly method of address programming and combined with its sophisticated bi FACP communication relays and contact device inputs for Model FDCIO422 controlled at the same address For the FACP the and input contacts can be controlled as a separate The relay is typically used where control or of external equipment is required Four 4 in out circuits are permissible on one 1 FDCIO422 module FDCIO422 is designed to monitor Normally Open or Normally Closed N C dry contacts 3230 CSFM 7165 0067 0264 and NYC Fire Department Approved interface module reports the status of the N O or contacts to the FACP FDCIO422 is used for the connection of up to two independent 2 2 A or four 4 independent B dry and N O configurable contacts Input lines can supervised for open short and ground fault conditions on end of line EOL termination resistor and configuration can be independently configured via the FACP for Trouble Supervisory or Status zones FDCIO422 has four 4 programmable outputs with 4 potential free latching type A dry relay for fire control installations panel FDnet provides supervised power limited supply for Model FDCIO422 The four 4 input 4 interface module provides status indication per LED each input output plus one 1 LED for device status included with Model FDCIO422 are four 4 EOL devices ohms as well as three 3 separators to separate wiring from non power limited wiring 4 In Out Interface Module 6155C Canada Limited continued following electrical mounting boxes can be used 12 cm 4 11 16 back box 12 cm 4 11 16 extension ring Optional 12.7 cm back boxes are available exclusively Randl Industries Inc FDCIO422 has a multi color LED that flashes when operating in standby condition if unit is in a Trouble event and RED to indicate a of event status FDCIO422 which is fitted with screw terminals connection to an addressable circuit is fully on the same circuits with all intelligent Model detectors Model manual stations or any other addressable modules such as Model HZM or Model HCP DPU FDCIO422 is compatible with the Siemens field programmer test unit Model DPU which is a portable menu driven accessory for programming and testing Model easily and reliably DPU eliminates the need for cumbersome mechanical programming methods such as or rotary switches and reduces installation and costs by electronically programming and testing FDCIO422 prior to installation via the microcomputer chip non volatile memory proper operation of Model DPU the technician the accessory program mode and enters the address In turn Model DPU automatically and verifies the address as well as tests testing FDCIO422 When in the mode Model will perform a series of diagnostic tests without the address or other stored data allowing to determine if testing Model FDCIO422 is properly DPU operates on AC power or rechargeable providing flexibility and convenience in and testing equipment from practically location Further vibration corrosion and other that deteriorate mechanical addressing are no longer a cause for concern Ratings Rating Voltage modules current Current 32VDC max Canada Limited Ratings switch ratings Voltage input meters 200 feet max cable length line to line line to shield Sizes Wire Gauge AWG 61m ft 200 ft max max AWG max AWG min Data Range Range Cover W x H x D and carrier P R O P E R T I E S Relay Ratings B C D C signaling line circuit limited 30 60 140 49 120 85 non freezing and condensing low temperature RAL 9017 9017 cm 12 cm 3.1 cm 4 4.7 1.2 g 1 Lb cm3 11.7 inch3 Open N O or Closed N C Contacts x 5 2 x 7 1 x 8 max VDC resistive VAC resistive Temp F 25 C x 3 max 2 x 4 1 x 5 x 2 max VDC resistive VAC inductive VDC resistive or 0.35PF VAC inductive Temp F 38 C Temp F 49 C AC output ratings are only applicable to Model interface modules that have Engineering ES version or higher The part number S54322 F4 A1 for Model FDCIO422 found on the back of each interface module and the version is placed just the right of the part number Page 3 for an illustration Refer to Installation Operation Manual A6V10324662 for further details ratings must not be used with modules with ES less than 10 ES number can be found on the label ES Model FDCIO422 Control Module Supplied Barrier Diagram In Inches FACPs Sheet XLS system overview system networkable system networkable for Ordering cm 4 adapter plate cm 4 back box cm 5 inch back box cm 5 inch back box C