Siemens FDCIO422 4-Input 4-Output Interface Module, Intelligent Peripheral Devices (for Canada), Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fdcio422-4-input-4-output-interface-module-intelligent-peripheral-devices-for-canada-data-sheet-2376154980.pdf |
---|---|
Type | |
Size | 1.42 MB |
Downloads |
Text Preview
Data Sheet Peripheral Devices 4 Output Interface Module FDCIO422 AND ENGINEER SPECIFICATIONS Four 4 inputs four 4 outputs via one 1 address Light emitting diode LED screen of all input output functions Input lines can be supervised for open short and ground fault conditions Supports A and B input circuit wiring Polarity insensitive utilizing SureWireTM technology Microprocessor controlled signal evaluation Two wire installation per addressable loop Power supply via C NET module Communication via C NET Individual addressing Four 4 AC rated DC rated outputs Mounts in one 1 electrical back box Optional 12 cm and 12.7 cm square back boxes FDCIO422 front plate included Restriction of Hazardous Substances RoHS compliant Electronic address programming is easy and dependable Easy front end access to programming port and wiring terminals Model 8720 DPU programs and verifies device address as well as performs test functionality ULC Listed 3230 CSFM 7165 0067 0264 and NYC Department Approved FDCIO422 is used for the connection of up to two 2 2 2 A or four 4 independent dry and N O configurable contacts Input lines can be for open short and ground fault conditions on end of line EOL termination resistor and configuration can be independently configured via the FACP for Trouble Supervisory or Status zones FDCIO422 has four 4 programmable outputs with 4 potential free latching type A dry relay for fire control installations FACP C NET module provides supervised power limited supply for Model FDCIO422 The four 4 input 4 interface module provides status indication per LED each input output plus one 1 LED for general device Also included with Model FDCIO422 are four 4 EOL of 470 ohms as well as three 3 separators to power limited wiring from non power limited wiring Overview four 4 input 4 output interface module Model from Siemens Fire Safety is designed to the means of interfacing direct shorting devices to Device Loop Card Model DLC FireFinder XLS as as the Cerberus PRO fire alarm control panels FACPs FDCIO422 which contains microcomputer chip technology and is polarity insensitive achieves state of an device through its highly method of address programming and combined with its sophisticated bi FACP communication relays and contact device inputs for Model FDCIO422 controlled at the same address From the FACP the and input contacts can be controlled as a separate The relay is typically used where control or of external equipment is required Four 4 in out circuits are permissible on one 1 FDCIO422 module FDCIO422 is designed to monitor Normally Open or Normally Closed N C dry contacts Each module reports the status of the N O or N C the FACP 4 In Out Interface Module Safety Products PRO for infrastructure continued are delivered in the following sizes 12 cm 4 11 16 back box 12 cm 4 11 16 extension ring Optional 12.7 cm back boxes are available exclusively Randl Industries Inc FDCIO422 has a multi color LED that flashes GREEN operating in standby condition AMBER if is in a Trouble event and RED to indicate a change of status FDCIO422 which is fitted with screw terminals for to an addressable circuit is fully compatible the same circuits all Siemens Model detectors addressable manual stations or any other intelligent modules such as Model HZM or Model Programmer Test Unit FDCIO422 is compatible with the Siemens field programmer test unit Model DPU 8720 which a compact portable and menu driven accessory for programming and testing Model FDCIO422 and reliably DPU 8720 eliminates the need for cumbersome mechanical programming methods such as or rotary switches and reduces installation and costs by electronically programming and testing detector prior to installation via the interface non volatile memory proper operation of Model DPU 8720 the technician the accessory program mode and enters the address In turn Model DPU 8720 automatically and verifies the address as well as tests Model When in the mode Model DPU 8720 perform a series of diagnostic tests without altering address or other stored data allowing technicians to if the detector is operating properly DPU 8720 operates on AC power or rechargeable providing flexibility and convenience in and testing equipment from practically any Further vibration corrosion and other that deteriorate mechanical addressing are no longer a cause for concern Ratings Rating Voltage modules current Current 32VDC max switch ratings Voltage input cable meters 200 feet max range line to line line to shield Sizes Wire Gauge AWG 61m ft 200 ft max max AWG max AWG min Data signaling line circuit limited 60 140 49 120 85 9017 g 1 Lb cm3 freezing and condensing low temperature RAL 9017 cm 12 cm 3.1 cm 4 4.7 1.2 Range Range Cover W x H x D and carrier P R O P E R T I E S AC output ratings are only applicable to Model interface modules that have Engineering ES version or higher The part number S54322 F4 A1 for Model FDCIO422 found on the back of each interface module and the version is placed just the right of the part number Page 3 for an illustration Refer to Installation Operation Manual A6V10324662 for further details Industry Inc Technologies Division ratings must not be used with modules with ES less than 10 ES number can be found on the label ES Diagram Model FDCIO422 Control Module Supplied Barrier Compatibility Table Sheet system networkable system networkable for Ordering 4 Input Four 4 Output Interface Module EOL Resistor 100 W EOL Terminal FDCIO422 EOL resistor Accessories via Randl Industries Inc cm 4 adapter plate cm 4 back box cm 5 inch back box cm 5 inch back box Industry Inc Technologies Division PRO Cerberus PRO Canada Limited North Service Road E Oakville Ontario 0H6 Canada 905 465 8000 www USA