Siemens FDCIO422 Cerberus PRO 4-In 4-Out Interface Module, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Cerberus PRO and Peripherals 4 Output Interface Module FDCIO422 Engineer Specifications Siemens provides Class X operation to NFPA 72 field wiring requirements Supports 252 ready per loop and in mixed mode to 30 devices between isolated Four 4 inputs four 4 outputs one 1 address Input lines can be supervised for open and ground fault conditions Light emitting diode LED display each input output status Supports Class A and Class B wiring Polarity utilizing technology Microprocessor controlled signal Two wire installation per addressable Four 4 auxiliary current AC rated current DC rated relay outputs Mounts in one 1 electrical back box Optional 4 inch 12 cm and 12.7 cm square back boxes Electronic address programming is easy dependable Simple front end programming access wiring terminals Model DPU programs verifies and well device functionality Restriction of Hazardous Substances compliant UL Listed ULC Listed FM 3230 7165 0067 0264 and NYC Department NYCFD Approved Product Overview four 4 input 4 output interface module Model FDCIO422 from Siemens Fire Safety is designed to provide the means of interfacing direct shorting devices Cerberus PRO Modular FireFinder XLS V FC9 series Cerberus PRO fire alarm panels FACPs FDCIO422 provides the ISOtechnology feature intelligent dual isolation meeting NFPA 72 Class X Style 7 survivability requirements Up 252 isolator devices per loop and in mixed mode up to 30 devices between devices non isolated devices wired polarity insensitive mode the devices between isolators can either be legacy or the contemporary devices isolation feature found on the FDCIO422 Intelligent Interface Modules provides information as to the location of the wiring fault When a short occurs panel can identify the fault automatically and the module recognizes the short in front of or behind the device simplifying fault condition location in the A true time saver versus typical troubleshooting methods relays and contact device inputs for Model FDCIO422 are controlled at the address From the respective Siemens FACP the relays and input contacts be controlled as separate functions The relay is typically used where control shunting of external equipment is required Four 4 independent input circuits are acceptable on one 1 Model FDCIO422 module Open N O or Normally Closed N C dry contacts are monitored by one 4 Input 4 Output module Model FDCIO422 FDCIO422 O module with white front plate in each shipment Infrastructure Building Products Sheet 9905 FDCIO422 is used for the connection of up to two 2 independent Class A or four 4 independent Class B dry and N O configurable contacts reports the status of either the N O or N C contact to the FACP Inputs can be configured via a Cerberus PRO FACP for the following zones Alarm Supervisory Status FDCIO422 has four 4 programmable outputs with four 4 potential free Form A dry relay contacts for fire control installations FACP loop technology provides supervised isolated power limited to a Model FDCIO422 interface module Optional use of provides true NFPA 72 Class X SLC protection against short circuit four 4 input 4 output interface module provides status indication per LED each input output plus one 1 LED for general device status Also included with FDCIO422 are four 4 EOL devices 470 ohms as well as three 3 to separate power limited wiring from non power limited wiring are delivered in the following sizes 4 11 16 inch 12 cm back box 4 11 16 inch 12 cm extension ring Optional 5 12.7cm back boxes are available exclusively via Randl Industries Inc FDCIO422 of a Cerberus PRO In 4 Out module mounting to an front plate Model FDCIO422 EOL resistor used with In 4 Out modules Model TB EOL terminal used with In 4 Out modules FDCIO422 has a multi color LED that flashes GREEN when operating in Normal standby condition in AMBER if a node in a Trouble event and in RED to indicate a change of event status FDCIO422 is fitted with screw terminals for connection to an addressable circuit and is fully compatible on the same of all Cerberus PRO and FireFinder XLS V H detection devices Cerberus PRO Modular X devices HMS addressable manual stations or any other addressable intelligent modules e g Model HCP or Model HZM X H devices on the same loop is mostly permitted but there are exceptions Models HLIM isolation and SBGA 34 audible base cannot be used with X devices on the same loop Programmer Test Unit Model FDCIO422 interface module is compatible with the Siemens field device programmer test unit Model DPU which a compact portable and menu driven accessory for electronically programming and testing Model FDCIO422 promptly and DPU eliminates the need for cumbersome unreliable mechanical programming methods e g dials and rotary and reduces installation and service costs by electronically programming and testing the detector prior to via the microcomputer chip non volatile memory found in each Model FDCIO422 interface module proper operation of Model DPU the technician selects the accessory program mode and enters the desired address In Model DPU automatically sets and verifies the address as well as tests the Model FDCIO422 module in the test mode Model DPU will perform a series of diagnostic tests without altering the address or other stored data technicians to determine if the detector is operating properly field device programmer test unit operates on AC power or rechargeable batteries providing flexibility and convenience the programming testing of fire safety equipment from practically any location Infrastructure Building Products Range Data Switch Ratings for Ordering VOLTAGE TYPE feet meters 120 49 RANGE feet 200 feet 61m S54312 F7 A1 LINE TO LINE max 4 Four 4 Interface Resistor W EOL LINE TO SHIELD max SIZES WIRE AWG AWG max AWG min Relay Output Ratings B C D 5 max C 2 7 1 8 3 max 2 4 1 5 2 max 2 2.5 1 3 Open N O or Closed N C Closed VDC resistive VAC resistive VDC resistive VAC resistive VDC resistive or 0.35pF VAC resistive Temp 25 Temp

Related Files