Desigo Fire Safety and Peripherals Fire CO Detector with ASAtechnology FDOOTC441 Engineer Specifications UL 268 7th edition Listed ULC Listed FM 3210 CSFM 7272 0067 0258 Built in ISOtechnology Competitive 10 year CO sensor lifetime Advanced multi criteria fire detector that optical thermal and CO sensors Differentiates between deceptive and an actual fire nuisance avoidance Compatible with H devices on the loop of Desigo Fire Safety FACPs Enhanced detection via forward and light scattering technology Supervisory feature for temperature and monitoring Complies with NFPA 76 Telco standard as high sensitivity detector UL Listed and FM Approved as a multi and VEWFD fire detector Low temperature warning for sprinkler per NFPA 25 UL 268A Listed for direct air duct use FPM UL 2075 and NFPA 72 requirements for self monitoring Remote sensitivity measurement capability Tri color detector status light emitting diode with 360 view Polarity insensitive via SureWire Responds to both flaming and smoldering Supervisory temperature monitoring signatures Automatic environment compensation Meets UL NFPA 72 requirements for self monitoring Compatible with Model DB 11 mounting bases Model DPU device programmer loop Restriction of Hazardous Substances RoHS Infrastructure Building Products Product Overview FDOOTC441 is an advanced multi criteria fire CO detector that a redundant optical thermal sensor Additionally Model FDOOTC441 ASAtechnology a distinctive forward backward light scattering that provides high tech unparalleled fire detection to the widest of fire types the detector to distinguish non threatening deceptive phenomena Model FDOOTC441 unit is UL 268 7th edition listed incorporating advanced ISOtechnology True Class X SLC operation use is optional greatly system reliability and circuit integrity while providing advanced fault finding unit may be programmed as a high sensitivity detector with a 0.2 ft Pre threshold and 1.0 ft Alarm threshold thus meeting the requirements of 76 Standard for the Fire Protection of Telecommunications Facilities as a Early Warning Fire Detector VEWFD FDOOTC441 detector offers a complete and contemporary solution to meet and CO life safety gas detection specifications Multi Criteria Fire CO Detector can be field programmed for simultaneous and or independent depending upon the precise customer and application requirements example the detector can simultaneously utilize the optical and heat sensors for fire detection multi criteria as well as provide independent outputs for gas life safety and heat detection Any combination of the sensors is possible detector is very versatile and meets the following fire industry standards Multi criteria fire detector UL 268 7th edition Monoxide CO gas detector UL 2075 detector UL 521 with five 5 possible field selectable combined with four 4 rate of rise options in duct plenum detector UL 268A monitoring for CO levels and temperature ranges 76 Telco Standard as VEWFD warning signal at 40 4.4 for sprinkler per NFPA 25 NFPA 72 instance the signals from the detector are monitored and processed via the algorithm technology which the signals into a neural network create an intelligent multi criteria detector Fire CO Detector FDOOTC441 ASAtechnology Datasheet 6153 usa siemens com fire Heat Receiver Backward Forward Labyrinth CO sensor Light Scattering Technology with CO sensor FDOOTC441 Overview continued encompassing result is an intelligent detector that provides enhanced detection capability to a wide range of products of while offering unsurpassed rejection to nuisance alarm sources including dust steam cooking aerosols and deceptive phenomena that could cause false alarms It is known at Siemens as the guarantee Model FDOOTC441 is a two wire addressable device it is then able to function as a multi purpose detector the revised requirements of UL 268 7th edition using smoke heat and CO gas detection in a singular pleasing package Comparable to other multi functional detectors Model FDOOTC441 also serves as a very viable detection solution that saves on product installation maintenance costs The unit value is with built in ISOtechnology the True Class X NFPA 72 compliant SLC isolation feature supporting up to 252 ready devices per loop When used in mixed mode a maximum of 30 non isolated devices between isolation wired in polarity insensitive mode Each detector fits into one 1 wall or ceiling footprint and only occupies 1 address on the signal line circuit SLC patented forward and backward light scattering technology which can distinguish both small and large products of operates at the core of each Model FDOOTC441 intelligent addressable CO with ASA sensor Each Model detector provides an eco friendly solution to legacy ionization detectors eliminating the need for a source along with inevitable HAZMAT disposal requirements Therefore each detector is capable of detecting smoldering and flaming fires all in ecologically efficient manner and is a valid RoHS compliant Restriction of Substances detection alternative to legacy ionization detectors 2 thermal sensors as well as an electromechanical CO sensor are included making each Model FDOOTC441 a robust reliable device suitable for the most challenging applications Additionally Model FDOOTC441 also as a carbon monoxide CO life safety gas detector compliant with NFPA 72 and UL2075 Light Scattering Technology high quality optical electronic measuring chamber for each Model FDOOTC441houses the following components 2 optical transmitters 1 optical receiver 2 thermal sensors 1 CO sensor transmitters illuminate the smoke particles from different angles one sensor creates forward scatter and the other creates backward scatter The scattered light subsequently reaches the receiver photodiode and generates a electric signal The combination of a forward and backward scatter facilitates optimum detection as well as between light and dark particles particle size type of detection creates standardized responsive behavior therefore optimizing the differentiation between signals and deceptive phenomena Additionally the heat sensors make it possible to detect fires without smoke CO sensor enables faster detection of fires with incomplete combustion as well as fires with the development of high of CO The combination of optical thermal and CO signals optimizes detection reliability this scenario generates the following advantages Early detection of all fire types of fire whether they generate light or dark smoke or no smoke The fire detector can be operated at a lower sensitivity level thus achieving a higher immunity against alarms that may otherwise be caused by cold aerosols e g by smoking electrical welding etc the case of an open fire the smoke sensitivity is heightened by a temperature increase a detection reliability the case of an open fire the smoke sensitivity is heightened by a temperature increase a detection reliability level that is comparable to a wide spectrum smoke detector that can be achieved and maintained is comparable to a wide spectrum smoke detector that can be achieved and maintained Infrastructure Building Products Operation continued Programmer Test Unit FDOOTC441 is compatible with the Siemens field device programmer test unit

Related Files