Siemens FHA2045-U1 Shield connec kit (EBA2001)

File Preview
File Preview
Click below to download for free

File Data

Name siemens-fha2045-u1-shield-connec-kit-eba2001-2415736809.pdf
Type PDF
Size 681.10 KB
Downloads

Text Preview

FHA2045 U1 connec kit EBA2001 Industry Inc Technologies Division notice notice specifications and availability subject to change without notice 2014 Copyright by Siemens Industry Inc reproduction dissemination and or editing of this document as well as of its contents and communication thereof to others without express are prohibited Offenders will be held liable for payment of damages All created by patent grant or registration of a utility model or design patent are by Industry Inc Technologies Division Fernwood Road Park NJ 07932 1 973 593 2600 2014 08 18 ID A6V10437430 en a Industry Inc Technologies Division connec kit EBA2001 FHA2045 Shield connec kit EBA2001 FHA2045 Description shield connection kit EBA2001 FHA2045 is for installation in the booster amplifier W EBA2001 and ensures reliable ground contact for the shielded cables to the OUT and Line IN connection X3 and X4 The shield connection kit EBA2001 is optional component and is supplied with all individual parts Installing the shield connection kit EBA2001 the shield connection kit EBA2001 in the enclosure FHA2016 connection terminal block threaded sleeves in back box conductor busbar L 100 mm 4 40 pan head Phillips screws L Plug the shield connection terminal block 1 onto the busbar 3 from above as the busbar 3 together with the shield connection terminal block 1 by the two screws 4 into the threaded sleeves in the back box 2 Industry Inc Technologies Division connec kit EBA2001 FHA2045 and installing the cable Preparing and installing the cable the cable mm inch mm 6.7 inch mm inch insulation shield the shielding Cut open the insulation approximately 200 to 220 mm 7.9 to 8 from the end of the and strip approximately 20 mm 0.8 from the cable Strip approximately 30 mm 1.18 from the end of the cable and remove the inner Cut off the wire braid of the shielding right at the end of the surround see the from the shielding arrow Industry Inc Technologies Division connec kit EBA2001 FHA2045 and installing the cable the cable and connecting the shield situation shielding in the shield connection terminal block connection kit EBA2001 installed cable to X3 or X4 amplifier mainboard 100 W EBA2004 Lay the shielded cable 3 so that the exposed braid comes to rest directly in the connection terminal block 1 necessary lay an additional shielded cable through the same shield connection block Tighten the knurled screws for the shield connection terminal block to fix the cable place Industry Inc Technologies Division by Industry Inc Technologies Division Fernwood Road Park NJ 07932 1 973 593 2600 2014 Siemens Industry Inc specifications and availability subject to change without notice ID order no A5Q00062099

Related Files