Siemens FHA2056-U1 FHA2056-R1 FS250 MPC Mechanical Migration Kit, Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fha2056-u1-fha2056-r1-fs250-mpc-mechanical-migration-kit-installation-instructions-5829613740.pdf |
---|---|
Type | |
Size | 1.38 MB |
Downloads |
Text Preview
INSTRUCTIONS FHA2056 U1 R1 Mechanical Migration Kit kit contains Left Bracket 25 x 1.75 x 3.25 Adapter plate 18.75 x 16.50 x 5.20 Outer Door 22.55 x 20.20 x 1.70 Door 20 x 19.50 x 1.0 Prior to installation of this migration kit verify that all necessary wiring is in place and in good shape panel location will accommodate the dimension of this kit Remove the FS250 MPC outer and inner door Refer to Figure 1 BACK 1 Removing Inner and Outer Doors from the Back Box If the inner door is spot welded cut off the locking hinge at the bottom and then slide out from the top remove the inner door Care must be taken to ensure that no sharp edges are protruding due to this Siemens Industry Inc Building Technologies Division Once the outer and inner doors are removed insure that the back box is free of all wiring Remove all the grounding connectors on the enclosure and all modules Save all and nuts to mount the new adapters Mount the 3 screws for the adapter plate as shown in Figure 2 Secure the adapter plate with additional 7 screws 3 AS SHOWN SLIDE ADAPTER IN PLACE 2 Mounting Adapter Plate inside the Back Box Install the left bracket as shown in Figure 3 and then connect the earth ground to the adapter HEX LOCK NUT PLACES SHOWN 3 Mounting the Left Bracket Mount the inner door to the left bracket with the screws provided Refer to Figure 4 THE SCREW FIVE OF THE SCREWS PROVIDED SLIDE INNER IN POSITION 4 Mounting the Inner Door Install the outer door as shown in Figure 5 and connect its earth ground connection GROUNDING AS SHOWN 5 Mounting the Outer Door For FC360 panels install the FCM901 U2 U3 into the inner door as shown in Figure 6 THE SCREWS THE MODULE 4 BOARD WITH OPERATING 6 Mounting the FCM901 U2 on the Inner Door Figure 7 For FS20 panels install the FCM2018 U2 U3 FCM2019 U2 U3 into the inner door as shown THE HEX NUTS DISCARD BRACKET 7 Mounting the FCM2018 U2 on the Inner Door For FS20 panels install the FS20 Modules onto the adapter plate as shown in Figure 8 MODULE SUPPLY UP TO AH 8 Mounting the FS20 Modules onto the Adapter Plate For FC360 panels install the power supply onto the adapter plate as shown in Figure 9 SUPPLY UP TO AH 9 Mounting the FC360 Modules onto the Adapter Plate Refer to the panel respective installation instructions for proper commission and operation security disclaimer products and solutions provide security functions to ensure the secure operation of building comfort safety security management and physical security systems The security functions on these products and are important components of a comprehensive security concept is however necessary to implement and maintain a comprehensive state of the art security concept that customized to individual security needs Such a security concept may result in additional site specific action to ensure that the building comfort fire safety security management or physical security for your site are operated in a secure manner These measures may include but are not limited to networks physically protecting system components user awareness programs defense in depth additional information on building technology security and our offerings contact your Siemens sales or department We strongly recommend customers to follow our security advisories which provide on the latest security threats patches and other mitigation measures http www siemens com cert en cert security advisories htm page has been left intentionally blank Industry Inc Technologies Division Fernwood Road Park NJ 07932 ID A6V101004423 enUS b A5Q00072062