Siemens FireFinder XLS - Speed, power, flexibility – everything a facility needs for today and tomorrow

File Preview
File Preview
Click below to download for free

Text Preview

Speed power flexibility everything facility needs for today and tomorrow XLS protects with premium features and continuous capabilities for infrastructure towering high rises to campuses XLS delivers the peace of mind and ease of use you need ultimate protection FireFinder XLS family gives you every you need to ensure code compliance of communications and a smart With more power more greater capacities and a high full color user interface the most intelligent fire safety system offers premium features and that address the needs of today remaining ready for the future processors and state of the art for virtually any application of all sizes can take advantage of processor speeds and state of the art which define the FireFinder XLS FireFinder XLS portfolio includes fire control panels for large applications support up to 2,500 addressable points panel up to 64 networked panels as as panels for small to mid sized with 500 addressable points or Plus it been engineered so facilities legacy MXL systems can easily and migrate to the newer FireFinder technology using adapters and line Additionally each FireFinder XLS can be networked into other members the FireFinder XLS family which means system can grow as requirements the XLS family is a high speed processor that supports 2,500 logic and up to 64 nodes Every signal quickly processed from simple to full alarm conditions Faster means shorter system reaction for all signals on both local and systems FireFinder XLS system installers and service technicians appreciate convenient data transfer database management tools USB enable the transfer of panel through a high speed Ethernet Fast file transfer is especially valuable supporting a global display on a large system with a separate database can be transfered and loaded without down the system using SD slots a backup SD card slot stores system data drawing files and text Technicians can then easily access that data when performing maintenance or service work codes in the U S including call for a broader range of capabilities in commercial and buildings of all types including dual smoke detectors carbon monoxide detectors combination CO and fire and new audible signal patterns carbon monoxide life safety events such the Temporal Code Four coded signal XLS meets and exceeds industry for the most complex and demanding projects high performance full color PMI interface and clearly communicates state conditions by displaying and responding to alarm signals alerts diagnostics security signals or dangerous conditions and system information Events are for added clarity Premier panel for complex such as a or hi rise Fast processing speed voice smoke and in a single node Compatible with a wide of detectors including high performance with or CO and traditional detectors High level interface fully with intelligent detectors offering competitive detection for datacenters clean rooms Sophisticated Person Interface with events provides insight to the of the alarm 8 Channel audio system 300 digital that exceeds and Mass System MNS Practical migration path MXL creates cost solution for older nodes True ring topology for and reduced cost with advanced features and options Hardware and Software Compatibility leading data connection options for faster more data transfer and management options USB connections make programming data transfer and management tools convenient and easily for authorized personnel High speed Ethernet port SD slot backup SD card slot and SD card that remains panel keeps critical system and configuration at hand Hot swap SD card file transfer without powering down system External References increasingly complex end to end life safety into one single system by accommodating up to functions in a single node Supports up to 1,000 external references or signals from panels and devices FireFinder XLS can activate and manage a complex smoke for Mass Notification System functions and other panel and facility control responses to fire system or events XDMC Digital Message Card capacity allows 100 minutes of recording time enables multi layered and pinpoint specific messaging Supports MP3 and WAV files Can broadcast two different messages simultaneously Includes a complete phrase library for building custom by linking single message components together a full sentence or paragraph for specific conditions locations Expanded messaging functions support all types of communications such as fire acts of weather events and other emergency conditions Composer Configuration Laptop Tool capacity meets your immediate needs and future expansion including Mass Notification MNS messaging capability Create up to 300 different voice or audio messages with total of 60 minutes of message time Allows recording editing and integration of customized using standard recording and audio applications Microsoft Voice Recorder High Performance Full Color PMI touchscreen provides a central point of annunciation control for networked FireFinder XLS and MXL panels Displays reports and responds to alarm signals trouble diagnostics security signals hazardous or conditions and other system information Full color LED display efficiently and visually a wide range of alarm types or system to facility staff and first responders The screen is color coded according to the event type appear in red troubles in yellow supervisory in security events in magenta Touch sensitive keys are physically responsive helping confirm their entries through tactile feedback every signal offers a deep path to report levels of detail about the signal or event Can be programmed to display messages in Spanish French and Hebrew for multilingual support with advanced features and options Advanced Detection Support a full range of Siemens detector technologies cost competitive single function optical and thermal detectors to sophisticated multi criteria and variable detectors High performance multi criteria ASAtechnologyTM with or without optional CO detection Audible signal patterns for carbon monoxide life safety such as the Temporal Four coded signal Very Early Warning Fire Detectors VEWFD comply NFPA 76 Telecommunication Standard UL 2075 NFPA 720 MXL Loop Card MLC customers to upgrade their system to take advantage the faster processor and advanced features in the XLS while keeping their investment in existing devices Upgrade a system loop by loop without requiring a new installation saving time and money Preserve investment in wiring and devices Full Integration with VESDA High Level Interface Support a full range of VESDA alarm and status signals for sensitive smoke detection and pinpoint diagnostics all fully compliant with NFPA 76 standards Full integration with VESDA aspiration detectors the need for separate relays and bulky wiring Recognizes and reports on four alarm levels per detector Specific trouble signals provide key information on the of trouble condition rather than a general signal Reports alarms and system status at the panel Reset the VESDA detectors right from the FireFinder panel Network Ring Card a true ring topology and replaces redundant pairs to the cost of installation and provide a higer degree of in system communications Provides a true ring topology by simply connecting the panel to the first in the network No more double conduit runs from separate directions Mix copper and fiber in segments

Related Files