Cerberus PRO Network Module FN2001 U1 Architect Engineer Specifications Product Overview Supports networking the following Models FC922 FV922 and FC924 fire alarm control panels Model FT924 fire terminal unit Electrical isolation between the system and FACP System bus input output connections Fast data transfer Holds up to 16 network nodes Style 4 or Style 7 wiring Ground fault monitoring Integrated degrade mode function UL 864 10th Edition Listed ULC S527 FM CSFM and NYC Fire Department C WEB network module Model FN2001 U1 is used to network up to 16 FACPs and fire terminal unit Model FT924 via the C NET system bus The C WEB network plugs into the Operating Unit Model FCM2018 U3 or Model FCM2019 U3 FN2001 U1 supports networking between the following systems Models FC922 FV922 Models FC924 FV924 Model FT924 Model FN2001 U1 connects to system bus inputs and outputs The module has monitoring and an degrade mode function Redundant is accomplished with one 1 network module per panel simple loop an electrical between the bus and the FACP Programming software held in flash electrically erasable programmable memory EEPROM FN2001 U1 is CSFM 7165 0067 0264 3010 and FDNY 6104 Approved Temperature and Humidity Range FN2001 U1 is UL 864 10th Edition Listed for indoor dry locations within a range of 120 3 49 2 to 32 3 0 2 and a relative humidity 93 2 at a temperature of 90 3 32 2 Infrastructure Building Products Sheet 9805 usa siemens com fire Data Inputs Voltage 30 VDC Current max Bus max Properties W x H x D 2.8 0.8 cm x 7.0 cm x 2.0 cm Lbs 20g for Ordering TYPE Network Module Documentation Terminal Unit PRO 252 504 point System PRO Intelligent Voice System Types and unshielded C NET UDP IP Rate in Mode kilobytes per second kilobytes per second between two 2 ft modules meters max isolation C NET and the FACP kV for loop fault error System Bus cross section 22 AWG Wire Gauge Unit Connection NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer PRO Industry Inc Infrastructure Building Products Fernwood Road Florham Park NJ 07932 973 593 2600 September 2021 6

Related Files