Siemens FN2001-U1 SAFEDLINK FCnet Network Module

File Preview
File Preview
Click below to download for free

File Data

Name siemens-fn2001-u1-safedlink-fcnet-network-module-6710934582.pdf
Type PDF
Size 864.33 KB
Downloads

Text Preview

Fire Safety FCnet Network Module FN2001 U1 Architect Engineer Specifications Product Overview Supports networking the following Models FC2025 FV2025 and FC2050 FV2050 fire alarm control panels Model FT2050 fire terminal unit Electrical isolation between the system and FACP System bus input output connections Fast data transfer Holds up to 16 network nodes Style 4 or Style 7 wiring Ground fault monitoring degrade mode function UL 864 10th Edition Listed ULC S527 FM CSFM and NYC Fire Department SAFEDLINK network module Model FN2001 U1 is used to network up to 16 and the fire terminal unit Model FT2050 via the FCnet system bus The network module plugs into the Operating Unit Model FCM2018 U2 or FCM2019 U2 FN2001 U1 supports networking between the following systems Models FC2025 FV2025 Models FC2050 FV2050 Model FT2050 Model FN2001 U1 connects to system bus inputs and outputs The module has monitoring and an integrated degrade mode function Redundant is accomplished with one 1 network module per panel simple loop is an electrical isolation between the system and the FACP Programming software is held flash electrically erasable programmable read memory EEPROM FN2001 U1 is CSFM 7165 0067 0264 3010 and FDNY 6104 Approved and Humidity Range FN2001 U1 is UL 864 10th Edition Listed for indoor dry locations within a range of 120 3 49 2 to 32 3 0 2 and a relative of 93 2 at a temperature of 90 3 32 2 Infrastructure Building Products usa siemens com fire Data Sheet 6805 Data Inputs Voltage 30 VDC Current max Bus Properties W x H x D 2.8 0.8 cm x 7.0 cm x 2.0 cm Lbs 20g max for Ordering Types and unshielded Module Sheet Documentation Terminal Unit Fire Safety 252 504 point System Fire Safety Intelligent Voice System UDP IP Rate in Mode kilobytes per second kilobytes per second between two 2 ft modules meters max isolation FCnet and the FACP kV for loop fault error Bus cross section 22 AWG Wire Gauge Unit Connection a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information NOTICE The information contained in this data sheet document is intended only of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer Fire Safety Industry Inc Infrastructure Building Products Fernwood Road Florham Park NJ 07932 973 593 2600 September 2021 6

Related Files