FN2013 U1 FN2014 U1 network module SM MM Infrastructure notice notice specifications and availability subject to change without notice reproduction dissemination and or editing of this document as well as of its contents and communication thereof to others without express are prohibited Offenders will be held liable for payment of damages All created by patent grant or registration of a utility model or design patent are by Industry Inc Infrastructure Fernwood Road Park NJ 07932 1 973 593 2600 2021 01 19 ID A6V12093642 en a Siemens Industry Inc 2021 28 of contents network module FN2013 in Desigo CerberusPRO Modular Wiring Wiring for Desigo Cerberus PRO Modular supply sockets 4 6 for HNET XNET HUB 4 SNC 7 8 data for FN2013 and FN2014 modules FN2013 FN2014 into existing D23xx networks Statement 28 of figures of fiber network module with COM BRK in housing CAB 1 2 3 1 of the fiber network module from above and the side 2 B HNET XNET wiring on NIC C 3 X HNET XNET wiring on NIC C 4 B RS485 HUB 4 FSI wiring 5 X RS485 HUB 4 FSI wiring 6 B wiring to an SNC Desigo CC Cerberus DMS NCC 7 X wiring to an SNC Desigo CC Cerberus DMS NCC 8 power A B 9 10 Connector EF1 EF2 FCnet C WEB A1 B1 A2 B2 11 Fiber optic cascading daisy chain 12 Star shaped fiber optic network 13 Fiber optic bridge 14 Adding a new panel in cascade 15 New panel in existing star shaped network 28 network module FN2013 Fiber network module FN2013 Description fiber network module multi mode MM and the fiber network module single mode can be used for the exclusive purpose of networking fire detection panels to the XNET SNC or HUB 4 over large distances using fiber optic cable fiber network modules have the following features Fiber network module FN2013 Single mode transmission up to Fiber network module FN2014 Multi mode transmission up to Two independent electrically isolated channels SC connections for fiber optic cable Trouble signaling via LED Mounting in panel Installation in Desigo CerberusPRO Modular Desigo Cerberus PRO Modular systems the fiber network module is installed on a bracket that can be mounted to the CAB 1 CAB 2 or CAB 3 back box or to optional CAB MP COM BRK takes up the same space as a CC 2 card cage The fiber network should first be secured to the COM BRK using the three screws provided with module then installed in the back box or mounting plate using the four screws with the bracket 28 network module FN2013 in Desigo CerberusPRO Modular the bracket and module are secured to the cabinet wire the module and connect optical fiber cable as described later in this document fiber network module and bracket cannot be installed behind a FCM2041 U2 LVM or FMT use the fiber network module in dry rooms 1 Mounting of fiber network module with COM BRK in housing CAB 1 2 3 network module mounting plate 28 network module FN2013 Views 2 Views of the fiber network module from above and the side SC connection for circuit 1 SC connection for circuit 2 LED indicators for data transmission errors and power supply for both B socket do not use tab for housing mounting A socket power supply socket for HNET XNET HUB 4 SNC socket for HNET XNET HUB 4 SNC 28 1Line 2EF214655583723firealarmresources com network module FN2013 Wiring Wiring for Desigo Cerberus PRO Modular In Desigo Cerberus PRO Modular systems Power B connections to the fiber and monitoring of its trouble contacts are not required as the fiber modules be installed in the same enclosure as the power supplies that provide power them Power A inputs can only be supplied by UL864 ULC S527 approved regulated sources PSC 12 TB3 or PSX 12 TB3 UL ULC LISTED REGULATED DC POWER SUPPLY POWER LIMITED ensure compatibility with the NIC C the HUB 4 or the SNC connect the polarity the circuit exactly as shown fiber network module FN2013 FN2014 does not feature ground fault supervision connections via HNET XNET ground fault supervision is via the NIC C 28 network module FN2013 class B HNET XNET on NIC C 3 Class B HNET XNET wiring on NIC C NC A A B circuit 1 monitored by NIC C 1 RS48 circuit 1 monitored by NIC C 1 do not use network module RS485 circuit 1 network module RS485 circuit 1 network module DC 2 network module GND 2 network module do not use RS485 ratings 8 V P P 150 mA max 2000 ft 610 m max 16 AWG max 18 AWG min Positive or negative ground fault supervision at 10 k Only connect to a UL864 ULC S527 approved power limited and regulated power e g PSC 12 TB3 EOL resistor required on NIC C or fiber network module 28 2 3 4 5 6 7 8NCNCNCONE SLOT OF CC 5 CC 2NIC CA1B1NCEF1A2B2NCEF2 NC Power APower BLine 1Line 2SIEMENSFN2013 FN2014RxTxRxTxNCNCNCNCNCNCNC9 10 11 12 13 14 15 1617 18 19 20 21 22 23 24DC 24 V 1 2 firealarmresources com network module FN2013 class X HNET XNET on NIC C 4 Class X HNET XNET wiring on NIC C