Siemens FPI-UK11 Upgrade Kit, Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name siemens-fpi-uk11-upgrade-kit-installation-instructions-0346251978.pdf
Type PDF
Size 636.80 KB
Downloads

Text Preview

Installation Instructions FPI UK11 Kit Industry Inc Technologies Division Park NJ 315 096065 5 Building Technologies Ltd Safety Security Products Kenview Boulevard Ontario 5E4 Canada the AC adapter before installation upgrade the Model FPI 32 Programmer Tester using the Model Upgrade Kit follow the steps listed below Remove the 9 screws around the sides of the FPI 32 and set to one side Remove the FPI 32 cover Remove one of the batteries Remove the black inner cover inside the detector base by the 2 screws marked A as shown in Figure 1 Set screws and the cover to one side Disconnect the wires from screw terminals 5 red and 6 Remove the black base by removing the 2 screws marked B shown in Figure 1 Discard the black base Mount the white base provided in the FPI UK11 Upgrade Kit the 2 screws removed in Step 5 Connect the black wires to screw terminal 6 and the red wires screw terminal 5 Place the black inner cover that was removed in Step 3 back the base Line up the holes and use the 2 screws set in Step 3 to secure the black inner cover in place the new IC2 Remove IC2 from its socket Do this by lifting one end of IC slightly then the other end Continue this process the IC comes free Use a short thin blade for best results Refer to Figure 2 for the of IC2 Discard the old IC the FPI 32 Rev 3.2 IC into the socket for IC2 the notch in the end of the IC to face the batteries indicated by the silkscreen outline on the PC board Figure 2 Be sure that all pins go into the proper holes Press down firmly to seat the IC properly the Base in the FPI 32 ProgrammerTester 1 IC2 in the FPI 32 ProgrammerTester 2 Replace the battery removed in Step 2 Replace the FPI 32 cover removed in Step 1 back on the and fasten it securely with the 9 screws Place the supplied FPI 32 Programmer Tester Operating front cover label over the existing label Remove the TRI MSI connections label adjacent to the TRI MSI plug and replace with the supplied TRI MSI CZM I label Install base detector lock according to Installation P N 315 080240 This locks the adapter in place with base the DB ADPT adapter into the base and rotate it until it in place W Program and Menu Modes changes have been made to the FPI 32 Program and modes Please refer to the FPI 32 Programmer Tester Opera Manual P N 315 090077 for further information 315 096065 5

Related Files