Siemens FS-RD2 FS-RD2-R Remote LCD Annunciator, Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fs-rd2-fs-rd2-r-remote-lcd-annunciator-installation-instructions-6592840713.pdf |
---|---|
Type | |
Size | 632.49 KB |
Downloads |
Text Preview
INSTRUCTIONS FS RD2 R LCD ANNUNCIATOR FS RD2 Remote LCD Annunciator is an optional accessory for the FS 250 Fire Alarm System Control The FS RD2 is black and the FS RD2 R is red The FS RD2 R provides a 4x20 character LCD display with the system status LEDs that display the event status of the system The enable keyswitch allows reset trouble silence acknowledge alarm silence and menu access for partial system control The lamp operation is also enabled by the keyswitch and is limited to the annunciator The annunciator mounts to a mounted 6 gang box 2 deep minimum The FS RD SB R Surface Backbox may be used for mounting The FS RD SB is black and the FS RD SB R is red SUPPLIED is to be done by qualified personnel who thoroughly read and understood this instruction Remote LCD Annunciator Screws Sheet Instructions 2 Disconnect BATTERY and AC prior to working on 1 3 Mount 6 gang backbox horizontally as required 4 Set dip switch for proper remote address see page 2 5 Attach conduit and run wires as required 6 Connect IN wires from fire alarm system control unit or remote as required 7 Connect OUT wires to next remote or 120 ohm E O L Assembly P N 140 050008 1 if last remote 8 Attach unit to backbox using four mounting screws 9 Apply power to system 10 Check for proper operation of functions ENABLE SILENCE RESET DIMENSIONS for power twisted pair cable for X X from panel previous remote and to remote or 120 ohm Resistor Assembly 140 050008 1 on the remote WIRING Power Limited and Supervised Industry Inc Technologies Division Park NJ 315 049103 6 DIMENSIONS to be installed in accordance with all local codes is not allowed Communication wiring must daisy chained from remote to remote block will accept a maximum of 12 AWG and minimum of 18 AWG twisted pair cable with a characteristic impedance approximately 120 ohms 4000 feet maximum from panel to last remote ADDRESS SWITCH SETTING following table shows the address dip switch settings for the FS RD2 R Switch 1 Switch 2 Switch 3 Switch 4 ON following table gives the currents necessary for power supply and battery calculations Voltage Type Designation Current 24 V DC A A ON steady indicates that power is applied to the FS RD2 R indicates that the FS RD2 R is not powered up OFF indicates that there is no trouble event in the system flashing indicates that at least ONE trouble event is unacknowledged steady indicates that ALL trouble events have been acknowledged AND INDICATORS FS RD2 R has a sounder 6 LEDs 1 LCD display 4 navigational push buttons M1 M4 4 dedicated push buttons and a keyswitch LEDs operate as follows Green Yellow Yellow Red SIL Yellow OFF indicates that NACs are in the OFF state if the system is in normal supervisory mode any event is present it indicates that the silenceable NACs are in the OFF state steady indicates that at least one silenceable NAC has been activated OFF indicates that there is no supervisory event in the system flashing indicates that at least ONE supervisory event is unacknowledged steady indicates that ALL supervisory events have been acknowledged OFF indicates that there is no pre alarm condition in the system flashing indicates that at least ONE pre alarm event is unacknowledged steady indicates that ALL pre alarm events have been acknowledged OFF indicates that there is no alarm event in the system flashing indicates that at least ONE alarm event is unacknowledged steady indicates that ALL alarm events have been acknowledged 315 049103 6 sounder operates as follows pushbutton operates as follows ENABLE SILENCED M4 LCD operates as follows Mode Event Mode OFF indicates that the system is in supervisory mode or all events in the system have acknowledged steady indicates that at least ONE unacknowledged alarm is present in the system pulsing indicates that at least ONE unacknowledged non alarm trouble supervisory or pre alarm is present in the system keyswitch must be in the ON position to activate the pushbutton The keys can only be removed in the position pressed initiates a system reset pressed acknowledges all events that are unacknowledged pressed silences all the activated silenceable NACs pressed gives access to USER menu to allow panel control to generate GENERAL ALARM ALERT and VIEW HISTORY refer to the FS 250 Owner Manual P N 315 049353 pushbuttons are used for navigation while in the USER screen events are present in the system M3 UP button is used to scroll up to the next event and M4 DOWN is used to scroll to the previous event M1 TOP button is used to place the list at the top of the queue M2 NEXT QUE is used to go to the next queue if present of lower priority 1 First Custom Message and System ID 2 Second Custom Message and System ID 3 Current Time 4 Day and Date Msg 01 Msg 02 am 1 Acknowledged or unacknowledged event Event type Event location in the list and time the event occurred 2 First 20 character custom message 3 Second 20 character custom message 4 of the device where the event occurred and a generic description of the device or trouble type 100 100 10 14 char custom msg01 char custom msg02 in rel events are displayed one at a time and cycle through a circular list once the first event or last event message is reached PRIORITY 315 049103 6