Siemens FT2003 Cerberus PRO Graphics Input Output Driver, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Data Sheet AND ENGINEER SPECIFICATIONS PRO Input Output Driver FT2003 U1 Communication interface Operable via the RS module Model FCA2016 U1 Functions on 24VDC power supply with the following PRO central stations 252 point addressable fire alarm control panel FACP Model FC922 504 point addressable FACP Model FC924 Fire Terminal Model FT924 A wiring Supervisory signals for external supply Provides connections to the following 34 external light emitting diode LED graphics display indicators 16 external graphics display buttons One 1 external key switch UL 864 9th Edition ULC S527 11 Listed Overview Graphics Input Output I O Driver Model from Siemens Fire Safety is a system on the RS Model FCA2016 U1 Model FT2003 U1 which serves as a standalone remote display operating provides the ability to build a graphic for the for the 252 504 point PRO FACPs The RS card is required for operation of Model Connection of each graphics I O driver cannot combined on the same RS wire with the Model remote display terminal and the Model remote peripheral module Model FT2003 U1 module which comes an enclosure or display panel consists of indicator printed circuit board PCB and a driver that is screwed together are 16 inputs to accommodate user defined commands such as Acknowledge Silence Reset Safety Products PRO continued FT2003 U1 also contains 32 outputs to highly programmable LEDs I O driver is operated as a remote graphics indicator at a distance of up to 3281 ft from its central station FT2003 U1 is also supplied via a separate power supply or the system supply from following stations Cerberus PRO 252 point FACP Model FC922 Cerberus PRO 504 point FACP Model FC924 Cerberus PRO Fire Terminal Model FT924 and Humidity Range FT2003 U1 will be UL 864 9th Edition for indoor dry locations within a range of 120 3 49 2 to 0 2 and a relative humidity of at a temperature of 90 3 32 2 Input Output Driver Documentation Sheet Number PRO 252 point system PRO 504 point system PRO Fire Terminal for Ordering S54400 C136 A1 Output Driver Cerberus PRO 252 504 pt FACPs Data Driver LED RS 485 and Design Admissible cable Graphic display data bus PCB Driver Input and Output of data bus PCB Indicator 1.5W x 13mA 1.3W x 13mA 32 VDC max 21 VDC 32 VDC max 21 VDC 32 VDC Amp max 24 AWG Wire Gauge connection ribbon cable FT2003 U1 Driver Indicator W x H x D W x H x D W x H x D x 8.1 x 2.0 cm x 20.6 cm x 5.0 Lbs 200g x 5.2 x 1.3 cm x 13 cm x 3.2 cm Lbs 90g x 3.8 x 0.5 cm x 9.6 cm x 1.2 cm Lbs 70g Indicator Operating for operating indicator 1 for Trouble watchdog Can be configured with the custom software Works Cerberus PRO Industry Inc Building Technologies Div Fernwood Road Florham Park NJ 07932 973 593 2600 Fax 908 547 6877 www USA Siemens com Cerberus PRO The information contained in this data sheet document is intended only as a summary and subject to change without notice The devices described here have specific instruction sheets that various technical limitation and liability information of these instruction sheets and the General Product Warning and Limitations document also contains important information are provided with the product and are available from Manufacturer contained in these documents should be consulted before specifying or using the For further information or assistance concerning particular problems contact the Manufacturer 2013 New Issue 0 Technologies Division Fire Safety in U S A

Related Files