Siemens FT2009-U1 FT2009-R1 LED Annunciator-32 Zone, Product Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-ft2009-u1-ft2009-r1-led-annunciator-32-zone-product-manual-2639048517.pdf |
---|---|
Type | |
Size | 1.03 MB |
Downloads |
Text Preview
FT2009 U1 FT2009 R1 Annunciator 32 Zone Manual 2 32 LEDs for 32 zones alarm supervisory trouble event display Display of system fault and ground fault from the entire system Communication with panel through UFP individual address External 24V DC power source required from an UL listed recognized for fire use power limited power supply In total up to 8 UFP type devices connected to a fire control panel Manually activate deactivate NAC Acknowledge and reset events from the entire system Self test function Flat elegant housing Fault On Test Fault On Test built in DC DC DC Industry Inc Technologies Division buttons key switch Fault On Test Color indicate alarm event or NAC activation event the zone indicate supervisory event from the zone trouble event from the zone LED annunciator power trouble event from the entire system indicate FT2009 communication failure at fire control panel ground fault event from the entire system are active are silenced waiting to be acknowledged events are acknowledged panel can be reset panel is reset Un silence the NAC in the event On Acknowledge events Test the fire control panel to quiescent condition the LEDs and local buzzer switch The key switch is used for control of button operation Lock key position locked unlocked Industry Inc Technologies Division switch EOL jumper X204 for address setting jumper for setting terminal resistor to UFP power supply and grounding X204 Dip switch is used for the FT2009 address setting and baud rate setting The 1 4 digits are for setting FT2009 address the 7 8 digits are for setting UFP baud rate The 5 and 6 digits are reserved for future use switch Rate bps bps bps bps switch to fire control panel FC901 FC2005 19200 bps is required jumper EOL jumper is used for setting terminal resistor of UFP IN OUT resistor is connected resistor is not connected Industry Inc Technologies Division In inch data voltage current quiescent current temperature temperature protocol terminals location DC Nominal 18.8 DC mA mA rel AWG Red dry device complies with Part 15 of the FCC Rules Operation is subject to the following conditions This device may not cause harmful interference This device must accept any interference received including interference that may undesired operation for ordering No No LED annunciator 32 Zone black LED annunciator 32 Zone red lb lb For Canadian applications the is deemed supplementary and can be used for display It must be housed in a ULC S527 approved locked enclosure Not approved for UL ULC MNS applications by Industry Inc Technology Division Fernwood Road Park NJ 08932 1 973 593 2600 No Siemens Industry Inc specifications and availability subject to change without notice