Siemens FT2014, FT2015 (with Model FCA2016-U1), Cerberus PRO Remote Display Terminals (with RS-485), Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Data Sheet AND ENGINEER SPECIFICATIONS PRO Display Terminals with RS interface FT2014 U3 R3 and FT2015 U3 R3 with Model FCA2016 U1 FT2014 U3 R3 and FT2015 U3 R3 2 4 backlit LCD screen Event and audible status LEDs Supports Style 4 or Style 6 wiring Built in transient protection Mounts in its own enclosure Optional system control Downloadable firmware FCA2016 U1 RS module provides to Remote Display Dual standardized RS interface Supports B Style 4 and A 6 wiring configurations Up to eight 8 devices on the RS 6 loop Universal Fire Protocol limitation Electrical isolation between the RS and the panel Ground fault monitoring UL 864 9th Edition Listed ULC Listed FM CSFM NYC Fire Dept Approved Built in flash electrically erasable programmable memory EEPROM Scroll buttons to view additional events Local sounder UL 864 9th Edition ULC Listed FM CSFM NYC Fire Dept Approved Overview Remote Display Terminals Models FT2014 U3 R3 and FT2015 U3 R3 are remote light emitting LED liquid crystal display LCD units that the existing status of a Cerberus PRO 252 system LED will illuminate for any given Alarm Gas Supervisory and Trouble Cerberus PRO event A 2 4 3 4 LCD screen will give of the event in alphanumeric form The screen can be scrolled to reveal additional are also available RDTs as well as Model FCA2016 U1 are 3010 CSFM 7165 0067 0259 and 6104 Approved RDT has separate LEDs for Alarm Gas Alarm and Trouble events on a Cerberus PRO Each LED will flash when are present The LED will change to acknowledgment of the event Safety Products PRO the remote display terminals have a LED to system power a separate ground fault LED and 4 additional user programmable LEDs There are two 2 LEDs that indicate the state of audible on the system One 1 LED to indicate that the circuits are One 1 LED to indicate the circuits have been the Cerberus PRO FACP is in its state with events present the screen will annunciate the ID data and will show the date time of day an event has been triggered to the Cerberus PRO the LCD display will show the following Event type and zone Custom message for that zone Usage of the zone or event addition to the aforementioned features the display show the total number of all types of events present the system display has a backlight feature that operates upon any event information or when any operator are pressed Display Terminals with RS interface continued Model FT2014 series display terminal has a local silence button which operates when any are displayed on the system Pressing any buttons will silence the local sounder when an is present remote display terminal has a navigation button is used for displaying next event or previous event in the sequence and has a local sounder button Model FT2014 series has one 1 button used to the local sounder The Model FT2015 series has 3 control buttons for events audible circuits and resetting the system there are three 3 user programmable available The Model FT2015 series has an key switch that enables the control buttons to remote display terminals are remotely connected to Cerberus PRO FACP via the RS interface The FC922 and FC924 Cerberus PRO panels require Model FCA2016 U1 RS module to provide to the remote display terminals FCA2016 U1 supports Style 4 or Style 6 wiring to eight 8 modules can be supported on a RS Input power of 24VDC is required to run the display terminals and can be provided from a PRO FACP or other UL Listed 24VDC power remote display terminals have screw terminals of supporting 12 to 22 American Gauge AWG remote display terminals can be mounted in a 2 electrical box or a 4 four inch square box No flush trim kit is required Each unit is 12 1 4 wide 9 22.9cm high 2 1 2 6.4cm deep RS interface is approximately 1.97 5cm 2.76 7cm high and 0.6 1.5cm deep weight of Model FCA2016 U1 is 0.044 Lbs 20g and Humidity Range are UL 864 9th Edition Listed for indoor dry within a temperature range of 120 3 to 32 3 0 2 and a relative humidity 93 2 at a temperature of 90 3 32 2 Data Normal mode Alarm 75 mA 136 mA structure mode of participants wire length 3,937 ft 1200 meters Interface Design screw terminal 8 max Cross section Wires to 22 the operating unit connections 55mA 55mA Documentation Peripheral Module Cerberus PRO system Cerberus PRO system Voice Communication system Sheet for Ordering S54400 B80 A1 Remote Display Terminal Remote Display Terminal Red S54400 B88 A1 Display Terminal control Display Terminal control Red S54400 A39 A1 RS Interface Cerberus PRO Industry Inc Building Technologies Div Fernwood Road Florham Park NJ 07932 973 593 2600 Fax 908 547 6877 www USA Siemens com Cerberus PRO The information contained in this data sheet document is intended only as a summary is subject to change without notice The devices described here have specific sheets that cover various technical limitation and liability information of these instruction sheets and the General Product Warning and Limitations which also contains important information are provided with the product are available from the Manufacturer contained in these documents should be consulted before specifying or the product For further information or assistance concerning particular problems the Manufacturer 2017 Supersedes sheet dated 8 2013 4 Technologies Division Fire Safety in U S A

Related Files