Name | siemens-ft2014-ft2015-with-model-fca2016-u1-desigo-remote-display-terminals-with-rs-485-data-sheet-6273418509.pdf |
---|---|
Type | |
Size | 1.15 MB |
Downloads |
Text Preview
Sheet Safety Products Fire Safety System Display Terminals with RS interface FT2014 U2 R2 and FT2015 U2 R2 with Model FCA2016 U1 AND ENGINEER SPECIFICATIONS FCA2016 U1 FT2014 U2 R2 and FT2015 U2 R2 2 4 backlit LCD screen Event and audible status LEDs Supports Style 4 or Style 6 wiring Built in transient protection Mounts in its own enclosure Optional system control Downloadable firmware Built in flash electrically erasable programmable memory EEPROM Scroll buttons to view additional events Local sounder UL 864 9th Edition Listed ULC Listed FM CSFM NYC Fire Dept Approved Overview Remote Display Terminals Models FT2014 U2 R2 FT2015 U2 R2 are remote light emitting diode liquid crystal display LCD units that show the status of a Desigo 252 504 point system LED will illuminate for any given Alarm Gas Alarm and Trouble Desigo system event 2 4 3 4 LCD screen will give details of the in alphanumeric form The display screen can scrolled to reveal additional events Optional capabilities are also available Remote Display Terminals as well as Model are FM 3010 FDNY 6104 and 7165 0067 0259 Approved remote display terminals have separate LEDs for Gas Alarm Supervisory and Trouble events on Desigo FACP when events are present The LED will to upon acknowledgment of the event Each LED will Industry Inc Technologies Division RS module provides to Remote Display Models FT2014 FT2015 Dual standardized RS interface Supports B Style 4 and A 6 wiring configurations Electrical isolation between the RS and Desigo panel Ground fault monitoring up to eight 8 devices on the RS 6 loop Universal Fire Protocol limitation UL 864 9th Edition Listed ULC Listed FM CSFM NYC Fire Dept Approved the remote display terminals have an LED indicate system power a separate ground fault LED four 4 additional user programmable LEDs are also two 2 LEDs that indicate the of audible circuits on the system One 1 LED to indicate that the circuits are One 1 LED to indicate the circuits have been the Desigo FACP is in normal state with no present the screen will annunciate the date time of day an event has been triggered to the Desigo the LCD display will show the following Event type and zone Custom message for that zone Usage of the zone or event addition to the aforementioned features the display show the total number of all types of events on the system The display has a backlight that operates upon receiving any event status when any operator buttons are pressed Remote Display Terminals with RS module 6812 continued Model FT2014 series display terminal has a local that operates when any new events are on the system Pressing the local sounder button or any operator buttons will silence the sounder when an event is present remote display terminal has a navigation button is used for displaying next event or previous information in the sequence and has a local silence button FT2014 series has one 1 button used to the local sounder The Model FT2015 series three 3 control buttons for silencing audible circuits and resetting the Additionally there are three 3 user buttons available The Model FT2015 has an integral key switch that enables the buttons to operate remote display terminals are remotely connected the Desigo FACP via the RS interface The 252 point and 504 point Desigo panels require Model FCA2016 U1 RS module to provide to the remote display terminals FCA2016 U1 supports Style 4 or Style 6 wiring to eight 8 modules can be supported on a given communications bus power is required to run the remote display and can be provided from a Desigo FACP or UL Listed 24VDC power source remote display terminals have screw terminals of supporting 12 to 22 American Wire Gauge remote display terminals can be mounted to a 2 electrical box or a 4 four inch square box No flush trim kit is required Each unit approximately 12 1 4 wide 9 22.9cm and 2 1 2 6.4cm deep RS interface is approximately 1.97 5cm 2.76 7cm high and 0.6 1.5cm deep The of Model FCA2016 U1 is 0.044 Lbs 20g and Humidity Range are UL 864 9th Edition Listed for indoor locations within a temperature range of 49 2 to 32 3 0 2 a relative humidity of 93 2 at a of 90 3 32 2 Data Normal mode Alarm mode of participants wire length Interface Design Admissible Cross Cable 75 mA 136 mA structure max feet 1200 meters screw terminal Wires to 22 the operating unit Plug in type connections 55mA 55mA Documentation Sheet Number Peripheral Module Desigo System Desigo System Voice system for Ordering Display Terminal Display Terminal Red Display Terminal control Display Terminal control Red Interface This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www USA Siemens com Desigo Fire Safety Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA in U S A 2017 sheet dated 8 2013 4