Siemens FTI2001-A1 Fire terminal board, Installation Instruction
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-fti2001-a1-fire-terminal-board-installation-instruction-4102398756.pdf |
---|---|
Type | |
Size | 887.15 KB |
Downloads |
Text Preview
FTI2001 U1 terminal board 3.1 Infrastructure notice notice specifications and availability subject to change without notice reproduction dissemination and or editing of this document as well as of its contents and communication thereof to others without express are prohibited Offenders will be held liable for payment of damages All created by patent grant or registration of a utility model or design patent are by Industry Inc Infrastructure Fernwood Road Park NJ 07932 1 973 593 2600 2020 08 26 ID A6V10315040 b en Siemens Industry Inc 2011 14 of contents terminal board FTI2001 assignments Wiring overview Supply output Supply input 1 2 elements data Statement 14 14 terminal board FTI2001 Fire terminal board FTI2001 Description fire terminal board FTI2001 is used in the network terminal The fire terminal board supplied via a UL Fire Protective Signaling Listed regulated power supply or via the output of the periphery board of a fire control panel or voice alarm fire panel For uninterrupted operation the external power source requires battery displays FT2014 or remote terminals FT2015 are supplied via the auxiliary DC FTI2001 has the following features 14 terminal board FTI2001 Two supply inputs for external DC supply Two peripheral data bus connections to the PMI mainboard and to the periphery Two supervised power limited outputs rated at DC 1 each Installation fire terminal board FTI2001 is for the network terminal 1 Installation of the fire terminal board FTI2001 into the network terminal for securing the fire terminal board on the back box terminal board FTI2001 fixing screw connect 14 terminal board FTI2001 for operating unit via ribbon cable for power supply output Vsys for supply input Vsys 2 for supply input Vsys 1 for the periphery bus for options the fire terminal board on the back box using the four fixing screws Use the ribbon cable supplied with the operating unit to connect operating unit to When connecting supplies make sure no AC is applied Connect power supply to Vsys input If redundancy is needed also connect power supply to X6 Vsys2 Only apply AC after wiring is complete 14 terminal board FTI2001 Views 2 Printed circuit board view of fire terminal board FTI2001 14 terminal board FTI2001 assignments and terminals used connection to the PMI mainboard terminal for supply outputs output 1 and 2 DC terminal for supply input 2 Vsys2 DC terminal for supply input 1 Vsys1 DC used connection for peripheral data bus of the fuse for supply output of the fuse for supply output of the voltage at the supply input Vsys2 of the voltage at the supply input Vsys1 used for supply output for supply output for supply input Vsys1 for supply input Vsys2 for supply supervision of X16 and X17 Pin assignments Wiring overview supply must be routed redundantly if the network terminal is supplied in a fail safe via a fire control panel or a voice alarm fire control panel of the FTI2001 fire terminal board Two separate supply inputs for redundant supply Two supervised supply outputs for devices on the serial RS485 circuit Power limited acc to NFPA 760 Ground faults detected at 1 All wiring in accordance of article 760 of NEC or local building code 14 terminal board FTI2001 assignments 3 Wiring for fire terminal board FTI2001 1 2 1 supply input necessary supply input for redundant supply supply outputs for peripherals to X3 on PMI mainboard for peripheral data bus supply connections allowed for PS Periphery board FCI2016 X1001 AUX 1 2 3 4 PAD 3 AUX PAD 4 AUX UL Fire protective signaling listed regulated power supply supply inputs input All power limited outputs are supervised in respect of input voltage Input is necessary for power supply Input is for redundant power supply supply outputs output Supervised and power limited outputs DC output voltage Max current of 1 per output 14 1Input 2Output 2Output 1PS 1PS 2Internalfirealarmresources com terminal board FTI2001 X15 Supply output 2 2 1 1 supply DC output redundant supply supply output DC X17 X16 Supply input 1 2 plug in terminal for supply input 2 redundant supply input supply DC supply DC 2 2 2 2 plug in terminal for supply input 1 supply DC supply DC 1 1 1 1 Indicators output 1 output 2 of the voltage at supply input 2 VSYS2 of the voltage at supply input 1 VSYS1 Meaning ok damaged ok damaged available supply and supervision is activated ON available supply and supervision is activated ON a correct indication the switch S1 must be in the corresponding position 14 terminal board FTI2001 elements input 1 X17 input 2 X16 output X15 terminals Adjustment elements input 1 VSYS1 X17 ON input 2 VSYS2 X16 ON 1 is not used default setting 1 is used supervised 2 is not used default setting 2 is used supervised Technical data current input 1 F203 input 2 F204 output 1 and 2 F201 F202 1 VSYS 1 2 VSYS 2