Siemens HCP, HCP-Z Intelligent Control Point Device, data sheet

File Preview
File Preview
Click below to download for free

Text Preview

Devices Control Point Device HCP HCP Z Engineer Specifications device for use with various Fire Safety fire alarm panels FACPs Used as a telephone zone speaker or notification appliance circuit Provides 24VDC NACs when used a Siemens FACP Used as a NAC under the Siemens Safety NAC product line Provides either a 25V 35 Watts or 25 Watts single channel zone only used with Modular and FireFinder Provides firefighters telephone only used with Siemens and FireFinder XLS FACPs Polarity insensitive with SureWire Mounts on standard electrical box 4 10.2 cm square or double gang No mechanical address programming a dial tone generator for use Supervised input and output power UL Listed ULC Listed CSFM and NYC Fire Dept Approved Product Overview HCP Z from Siemens Fire Safety is an intelligent control point device for use with Siemens Fire NAC series of alarm signaling devices various Siemens Fire Safety FACPs which include Siemens Modular as as the 50 point 252 point and 504 point addressable FACPs can recognize HCP devices HCP Z can be configured as an independent remotely located telephone speaker zone or NAC Model HCP Z is programmed and tested using the Programming Test Unit Model DPU which eliminates the need for mechanisms i e program jumpers DIP switches or rotary HCP is supervised for loss of 24 VDC input power as well as short or open wiring Model HCP Z mounts in a standard double gang or 4 10.2 square electrical box Model HCP Z is programmed as a speaker zone the high power audio risers supervised using the Model ZAC 40 zone amplifiers Programmed as a telephone the telephone riser is supervised by the 8 Eight Zone Telephone Card Model Specifications HCP Z communicates through the analog loop of Models XDLC for Modular Model DLC for FireFinder Each control point device can be wired in either A Style Z or Class B Style Y The 24 VDC power input comes from either the or from any UL Listed power limited auxiliary power supply Siemens Modular FireFinder XLS systems compatible power supplies for the control point device are Model PSC 12 power supply Model PSX 12 power supply extender Models PAD 3 PAD 4 NAC extenders or Any power limited 24 VDC power that is UL Listed for fire use the Siemens 50 point 252 point and addressable fire systems power supplies include Siemens NAC circuits PAD 3 or PAD 4 NAC Extenders Any power limited 24 VDC power that is UL Listed for fire use Data Sheet 6311 Infrastructure Building Products usa siemens com fire Model HCP Control Point Device Diagram Use a standard 3 1 2 8.9 cm double gang electrical or a 4 10.2 cm electrical box that is 2 1 8 cm deep with either a 1.5 deep extension or a 3.2cm deep plaster ring Specifications cont Modular 252 and 504 point systems support to 60 Model HCP Z devices per SLC Siemens 50 addressable fire system supports a maximum of addressable devices of all types The maximum NAC load that may be connected Model HCP Z into a 50 point 252 point or 504 point system is 1.50 Amps at 24VDC Temperature and Humidity Range H series intelligent control point device is UL 864 for indoor dry locations within a temperature of 120 3 49 2 to 32 3 0 2 a relative humidity range of 93 2 at a of 90 3 32 2 NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer 5 12.7 cm switchplate and fasten with two 2 screws HCP into the box and the device plate to the box Manufacturer Cover the device front plate with Connect the field wiring Insert contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product Data Draw or Standby for Ordering Control Point Device Control Point Device USA denotes Country of Origin Industry Inc Infrastructure Building Products Fernwood Road Florham Park NJ 07932 973 593 2600 2021 6

Related Files