Siemens HLIM Line Isolator Module, Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name siemens-hlim-line-isolator-module-data-sheet-8469135027.pdf
Type PDF
Size 847.92 KB
Downloads

Text Preview

Data Sheet Safety Products AND ENGINEER SPECIFICATIONS Devices Isolator Module HLIM HLIM Z Used on intelligent device circuits connected to any the following fire only or intelligent voice IVC systems Siemens 50 point addressable fire alarm control panels FACPs connection to the signaling line circuit SLC Siemens 252 point 504 point addressable IVC systems FACPs connection to the SLC Siemens Modular via the Class X Device Loop Card Model XDLC FireFinder via the Device Loop Card Model DLC Up to 15 HLIM HLIM Z devices can wired to one 1 addressable loop A maximum 20 addressable devices are permitted between each HLIM Mounts in a 4 10.2 cm square 2 1 8 5.4 cm or 8.9 cm deep double gang electrical box Short circuit isolation Style 4 or Style 6 wiring Requires no programming Local light emitting diode LED indicator Overview Line Isolator Module Model HLIM HLIM Z protection of short circuits on the line circuits SLC via use with Siemens and 252 504 point addressable systems well as the Class X Device Loop Card XDLC Modular panels Model DLC for FireFinder a short circuit is detected Model HLIM isolates the affected segment on the allowing the remaining devices to functioning Siemens Modular and FireFinder systems to 15 line isolator modules Model HLIM may be wired on one 1 Model XDLC DLC loop respectively For Siemens 50 and 252 504 point addressable systems to 15 HLIM HLIM Z modules can be wired one 1 SLC Industry Inc Technologies Division Less susceptible to faults Does not occupy a device address Switchplate 5 12 7 cm included UL 864 9th Edition Listed ULC Listed FM 3015946 CSFM 7300 0067 0242 and Fire Department 6160 Approved HLIM Z self restoring and HLIM reconnects to the circuit segment the fault is removed is one 1 yellow LED which indicates of the peripheral device Model HLIM can be wired in either a Style 4 or Style 6 Model HLIM HLIM Z does not a device address on any of the following XLDC for Siemens Modular panels Model for FireFinder or the SLC for the Siemens and 252 504 point addressable FACPs HLIM HLIM Z mounts to a 4 10.2 cm 2 1 8 5.4 cm deep or 3 1 2 8.9 cm double gang electrical box A switch plate an opening for the LED is included per There is no type of programming necessary operation of each line isolator module Isolator Module 6310 Ratings Siemens Modular and FireFinder panels Diagram Loop Card XDLC and DLC Current Draw For Siemens 50 point 252 point 504 point addressable panels Line Circuit Current Draw and Humidity Range HLIM HLIM Z is UL 864 9th Edition within a range of 120 3 49 2 to 32 3 0 2 and at a relative humidity of 93 2 at a temperature of 90 3 32 2 dry for Ordering Isolator Module Isolator Module USA denotes C ountry o f O rigin This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www USA Siemens com FIRE in U S A Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA 2018 sheet dated 11 2015 4

Related Files