Siemens ILED-X Series Intelligent Remote Alarm Lamps, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-iled-x-series-intelligent-remote-alarm-lamps-data-sheet-4692583701.pdf |
---|---|
Type | |
Size | 919.01 KB |
Downloads |
Text Preview
and Detection Devices Device Remote Alarm Lamps ILED XC ILED XW Architect Engineer Specifications Multi color intelligent light emitting ILED mimics the detector Illuminates in any variation of AMBER RED Dual built in isolators Meets Class X Style 7 requirements Low current draw Restriction of Hazardous RoHS compliant Additional accessory capability when used an audible or relay base Wall and ceiling lamps can be and independently by fire alarm control FACP logic Ceiling and wall can be mounted on a device loop e g communication loop the wiring on that loop UL864 UL2572 UL2017 Listed CAN ULC S576 Listed File S24304 Vol 3 Product Overview Siemens Fire Safety Intelligent Remote Lamps Models ILED XC ILED XW are tailored for use with initiating devices that are concealed or otherwise easily within view e g above suspended ceilings under sub floors in ventilating ducts normally locked vaults or closed rooms etc Intelligent Remote Alarm Lamps can connect to Siemens addressable fire alarm panels FACPs Model ILED XC is mounted on a 4 inch 10.2 cm octagon box Model ILED XW is fastened on a single gang electrical box The module one 1 address on the loop Refer to installation manual P N A6V101055484 to ensure Model ILED XC ILED compatibility with the Siemens FACPs intended for use in the given application ILED XC and ILED XW provide intelligent built in dual isolation meeting Class X 7 survivability requirements for shorts while providing reliable alarm to the Siemens FACP Up to 190 isolators are allowed per loop and up 30 devices can be connected between isolators via wiring in a polarity insensitive The devices between isolators can be cid 67 H or later cid 67 X generation devices Specifications isolation feature found on the Intelligent Remote Alarm gives information as to the location of the short a short occurs the panel can identify the short and the module recognizes the short location front of the device or behind the device Overall the built in isolators improve the diagnostics and area of short and report when a Class X module is misconfigured modules are configurable by compatible panel s in an polarity sensitive or non polarity mode When a Model ILED X series lamp is as an isolator it may serve a dual purpose by functioning as an input output device and provided by panels by identifying when an ILED X series is configured as an isolator but is wired incorrectly in polarity insensitive mode there is no regulatory limitation for mounting the be advised that Model ILED XC is often ceiling and Model ILED XW is intended for wall mounting intelligent remote lamps can be mounted on a compatible panel device loop LED can be controlled by FACP logic cid 326 even on different the network cid 326 since Model ILED XC or Model ILED XW is its own unique address Advanced troubleshooting or on another panel ILED XC Alarm Lamp Ceiling Technologies Division Data Sheet 6169 cid 3 usa siemens com fire ILED XW Alarm Lamp Wall ILED XC faceplate Single gang switchbox supplied Blank plate Operation Programmer Test Unit Remote Alarm Lamp is programmed with the field device programmer test unit Model DPU is a compact portable and menu driven accessory electronically programming and testing Siemens modules and devices promptly and reliably instance the field technician selects the accessory mode and enters the desired address Vibration and other deteriorate mechanisms are no longer a cause concern Each remote alarm lamp is connected to DPU with the programming cable provided with the This programming cable P N 110 694927 utilizes ILED XC Model ILED XW lamp Since the Class X Intelligent Remote Alarm are advanced initiating devices the Model DPU firmware update is required set in cid 67 test mode Model DPU will perform a of diagnostic tests without altering the address or Wall Remote Alarm Lamps stored data allowing technicians to determine if detector is operating properly field device programmer test unit operates on AC or rechargeable batteries providing flexibility convenience in the programming testing of fire equipment with the use of a Model DPU unit there is longer a concern with any vibration corrosion and deteriorating conditions that compromises the of a mechanical addressing mechanism practically any Application Note ILED XC and ILED XW can also be utilized as a accessory of a detector when assigned to respond detectors that have remote relay or audible bases Temperature and Humidity Range Remote Alarm Lamps are UL Listed ULC Listed operating conditions for each Remote is 32 0 to 120 49 with a relative of no greater than 95 non condensing Technical Data for Ordering cid 55 cid 60 cid 51 cid 40 cid 3 S54370 B5 A1