Siemens LVM Cerberus PRO Modular Live Voice Module, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

PRO system Voice Module LVM Engineer Specifications Dynamic microphone with switch Coil cord Fully supervised Pre announce tone LED Ready to page LED Six 6 programmable switches Six 6 pairs of built in LEDs Speaker with volume control Mounts to the door of CAB 1 CAB2 CAB3 or lobby enclosure UL864 CAN ULC S576 Listed CSFM NYC Fire Department Product Overview Live Voice Module Model LVM provides a supervised high quality and microphone to give firefighters a means of sending live voice to specified audio zones Model LVM mounts on the inner door of a CAB2 CAB3 or remote lobby enclosure Model LVM includes a with a push to talk switch and coiled cord The microphone and switch are fully supervised LVM also provides a GREEN preannounce LED which the pre announce signal is active at the selected and a GREEN ready to page LED which indicates zones are ready to be paged pre announce signal can be programmed as a tone or and the duration is adjustable from 0 to 10 seconds 1 second increments A built in speaker with volume allows the monitoring of the audio channels front panel of Model LVM contains six 6 switches six 6 pairs of LEDs Each pair of LEDs contains one bi color RED GREEN and one 1 YELLOW LED six 6 switches can be programmed for manual functions as well as generic system functions the switches are used as generic switches all can be programmed for ON OFF or FLASHING LVM is supervised by the Model DAC NET card is assigned to one 1 of the 99 Model DAC NET addresses CAN addresses LVM Voice Module Technologies Division Sheet 8333 Temperature and Humidity Range LVM is UL Listed for indoor dry locations within a temperature range of 120 3 49 2 32 3 0 2 and a relative humidity of 93 2 at a temperature of 90 3 32 2 Ratings CURRENT max for Ordering TYPE Voice Module NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer PRO Industry Inc Technologies Division Fernwood Road Florham Park NJ 07932 973 593 2600 2017 New Issue 0

Related Files