Siemens MLC (Legacy-panel) Line Card for Desigo Modular systems, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-mlc-legacy-panel-line-card-for-desigo-modular-systems-data-sheet-9574382106.pdf |
---|---|
Type | |
Size | 972.99 KB |
Downloads |
Text Preview
Fire Safety system MXL Line Card MLC Architect Engineer Specifications Capability to report Alarm Trouble Supervisory Security Status commands Two 2 intelligent analog device circuits 60 intelligent devices per circuit Independent control of detector relays Up to 60 relays per circuit Accepts remote modules On board microprocessor On board ground fault detection Programmable Input Output module Short circuit isolation with Model LIM 1 Remote smoke detector adjustor Intelligent contact monitoring devices Class B Style 4 or Class A Style 6 positions Supports T Tap wiring for Class B Approved Degrade mode Supports audible bases UL864 CAN ULC Listed Product Overview MXL Line Card Model MLC is an optional card for the Desigo Fire Safety Desigo Modular fire alarm control panel FACP that supplies two intelligent analog circuits utilizing the Model I Model ID Model IL or Model FP type intelligent devices MLC occupies two 2 addresses on the HNET network and through use of a unique communications protocol devices connected to the MLC circuits are dynamically supervised by a Desigo Modular system detectors are monitored for sensitivity obscuration and notification given when the sensitivity obscuration is outside normal parameters Specifications of the Model MLC circuits supports the use of up to 60 Alarm Trouble Status and Supervisory devices Additionally remote devices and intelligent control points Model ICP B6 are supported Model MLC circuits zone modules Model CZM 1B6 of certain smoke detectors can be queried and at the Desigo Modular system control panel sensitivity obscuration as well as other device can be displayed and printed at the Desigo system MLC supports the use of relay bases and audible independently controllable To provide analog short circuit isolation the Model LIM 1 module can used to prevent a single short circuit from interrupting communication Model MLC circuit can be wired in either a Class B 4 or Class A Style 6 configuration When using Style 4 method T Tap wiring is permitted with no loss supervision MLC has an on board microprocessor which provides ability to function in a degrade mode and initiate alarm even if the Desigo Modular system main central unit CPU fails Model MLC plugs into one 1 slot in the Model CC 5 or Model CC 2 card cage Model MLC Card legacy panel to Modular panels Technologies Division Data Sheet 7354 Temperature and Humidity Range Model MLC is UL 864 9th Edition Listed for indoor dry locations within a temperature range of 120 3 49 2 32 3 0 2 and a relative humidity of 93 2 at a temperature of 90 3 32 2 Documentation TYPE Modular overview for Ordering TYPE Line Card from Siemens legacy into a Desigo Fire Modular system The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer Data contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer Fire Safety Industry Inc Technologies Division Fernwood Road Florham Park NJ 07932 973 593 2600 2017 Rev 0 Issue