Siemens MPF-RK, MPR-RK, PTB-RK, BP-RK XLS Rack Mount Kits (RKs), Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-mpf-rk-mpr-rk-ptb-rk-bp-rk-xls-rack-mount-kits-rks-installation-instructions-7984652103.pdf |
---|---|
Type | |
Size | 814.63 KB |
Downloads |
Text Preview
Installation Instructions XLS Desigo Fire Safety Modular Cerberus PRO Modular Mount Kits RKs MPR RK PTB RK BP RK Model RK series of panels and cables from Siemens Industry Inc provides 19 rack mounting for FireFinder XLS Desigo Fire Safety Modular Cerberus Modular modules The table below lists the individual rack mount kits along with specific modules that mount onto them Fire Safety Modular Cerberus PRO Modular Rack Mount Kits are for use only in dry environments FireFinder XLS Desigo Fire Safety Modular Cerberus PRO Modular module that mounted must be ordered separately HARDWARE FireFinder XLS Desigo Fire Safety Modular PRO Modular rack mounting panels mount a standard 19 wide x 18 or 23 5 8 deep 6 foot rack Model XLS RK19 P N 500 634778 See 1 The rack is supplied with the following back and top panels door with clear lens tray mounting hardware front door has a standard Siemens lock with key 1 lists the recommended locations front or rear the rack mounted modules and the panel heights of rack mount kits See Figures 2 3 4 and 5 315 034778 AH 1 Rack Inc Inc Inc Industry Inc Inc Infrastruct Infrastruct Infrastructureureureureure Infrastruct Infrastruct 2 Front Panel 3 Back Panel 4 Back Panel 5 Blank Plate each module to its designated rack mount kit See Table 1 using the hardware installation instructions provided with the module Refer to Table 2 for a list of instructions compliance with NEC Article 760 all power limited fire protective signaling must be separated a minimum of inch from all of the following wiring within a control panel light 1 or non power limited fire protective signaling conductors installing power limited field wiring the installer must comply with NEC article which states fire alarm power limited circuits are installed using Types FPL FPLR FPLP or substitute cable provided these power limited cable conductors extending the jacket are separated by a minimum of 0.25 in 6.35 mm or by a noncon sleeve or nonconductive barrier from all other conductors power limited wiring is not used within the XLS RK19 rack then the following do not apply In that case be sure to follow standard wiring practices Industry Inc Infrastructure 315 034778 AH Entering The Rack Limited Wiring wiring must enter from the right side of the rack Wiring Straps Limited Wiring wiring must enter from the left side of the rack Wiring must be in the shortest and must not overlap any other wiring primary mains input must have a separate or dedicated circuit breaker Wire in with local codes and NEC 760 Straps are included in each Rack Mount Kit and are used to properly ground assembly refer to Table 2 Refer to Figure 6 for placement of these straps RE ANNOUNCE TONE TO PAGE VOLUME FAIL FAIL FAIL FAUL T 12A FAIL 4A FAIL FAIL FAIL FAIL FAUL T 12A FAIL 4A FAIL FAIL FAIL FAIL FAULT 12A FAIL 4A FAIL MOUNTING MOUNTING Limited Wiring Limited Wiring 6 and Ground Strap Placement Industry Inc Infrastructure 315 034778 AH SECURITY DISCLAIMER provides a portfolio of products solutions systems and services that security functions that support the secure operation of plants sys machines and networks In the field of Building Technologies this in building automation and control fire safety security management as as physical security systems order to protect plants systems machines and networks against cyber threats is necessary to implement and continuously maintain a holistic state of security concept Siemens portfolio only forms one element of such a are responsible for preventing unauthorized access to your plants sys machines and networks which should only be connected to an enter network or the internet if and to the extent such a connection is neces and only when appropriate security measures e g firewalls and or net segmentation are in place Additionally Siemens guidance on appropri security measures should be taken into account For additional informa please contact your Siemens sales representative or visit https portfolio undergoes continuous development to make it more se Siemens strongly recommends that updates are applied as soon as they available and that the latest versions are used Use of versions that are no supported and failure to apply the latest updates may increase your to cyber threats Siemens strongly recommends to comply with advisories on the latest security threats patches and other related published among others under Industry Inc Infrastructure Park NJ Canada Ltd North Service Road East Ontario 0H6 Canada ID A6V10239130 315 034778 AH