Siemens MTH-MC-R-AR and ST-MC-R-AR Agent-Release Signaling Appliances, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Data Engineered Fire Suppression Systems Signaling Appliances MTH MC R AR Horn Strobe ST MC R AR Standalone Strobe AND ENGINEER SPECIFICATIONS MTH MC R AR Device text reads Agent over a red cover Series MTH appliances have IN OUT terminations that accept two 12 18 American Wire Gauge AWG wires each terminal Inputs are polarized for compatibility with reverse polarity type supervision One 1 alarm appliance with eight 8 signals to provide superior sound for various ambient and wall with two 2 field selectable output levels Code 3 Horn and Tone meet ANSI NFPA pattern for standard emergency signaling Audible and strobe can operate from a NAC circuit or from separate NAC with any of the eight 8 audible MTH Strobe models are available with MC Multi Candela strobes with selectable candela settings at 15 30 75 110cd Synchronized using the Siemens DSC sync FS 250 panel XLS panel or PAD 3 power supply with sync protocol No additional trim plate required for flush Designed to meet or exceed ADA NFPA ANSI Standards and Accessibility Complies with OSHA 29 Part 1910.165 UL Listed and ULC Listed CSFM Pending NYMEA Approved Strobe Strobe ST MC R AR Device text reads Agent over a red cover Provides four 4 selectable light output to one 1 unit Ceiling mount Multi Candela models are with field selectable candela of 15 30 75 95cd or 115 177cd round or square Strobes produce 1 flash per second over regulated voltage range Xenon flashtube with solid state circuitry in a polycarbonate lens is used to maximum visibility and reliability effective visible signaling All inputs are polarized for compatibility Synchronized using the Siemens DSC sync FS 250 panel XLS panel or PAD 3 power supply with sync protocol Fast installation with IN OUT screw using 12 to 18 AWG wire Meets OSHA 29 Part 1910.165 UL Listed and ULC Listed CSFM Pending NYMEA Approved Signaling Appliances SinorixTM 6634 Industry Inc Technologies Division Overview MTH MC Model MTH MC series of strobes provides to four 4 selectable candela settings 15 75 and 110 The Model MTH MC series of also provides a non synchronized appliance when connected directly to a control panel FACP Model MTH MC series of strobes are listed wall mount only with the backboxes in these instructions Mounting Options section of this document Multi tone Strobe Appliances use a Xenon with solid state circuitry enclosed in polycarbonate lens to provide maximum and reliability for effective visible multi tone strobe appliances are UL under Standard 1971 for Signaling for the Hearing Impaired and UL 464 for Audible Signal Appliances Multi tone Strobe Appliances are also Listed under Standard CAN ULC S526 02 Visual Signaling and under Standard for Audible Signal Devices Fire Alarm Systems ST MC Model ST MC Strobe Appliances can a non synchronized strobe appliance connected directly to a Fire Alarm Panel FACP or provide a strobe appliance when to a notification appliance circuit the Siemens sync protocol Model ST MC series of strobes are UL under Standard 1971 Signaling Devices the Hearing Impaired for indoor Fire Service and ULC Listed under CAN ULC S526 07 for indoor Fire Service The Multi Candela Strobe four 4 selectable light output in one 1 unit These strobes are for wall mount only with the backboxes in these instructions Mounting Options section of this document Model ST MC series of strobes have an strobe mounting plate that can be to a single gang double gang 4 100mm European backbox or SHBBS backbox The Model ST series of use a Xenon flashtube with solid state enclosed in a polycarbonate lens to maximum visibility and reliability for visible signaling All inputs are for compatibility with standard polarity supervision of circuit wiring by FACP Model ST MC series of strobes are listed by and ULC for indoor use with a range of 32 to 120 0 to and maximum humidity of 93 2 The effect of shipping and storage shall not adversely affect the of the appliance when it is stored the original cartons and is not subjected to or abuse All Canadian installations should be in accordance the Canadian Standard for the Installation of Fire Systems CAN ULC S524 and Canadian Code Part 1 Final acceptance is subject to the having jurisdiction AHJ 72 ANSI 117.1 conforms to ADAAG Equivalent Guidelines in using fewer higher intensity within the same protected area Industry Inc Technologies Division Diagrams Shown In Inches Shown In Inches MC R AR MC R AR MC R AR Options Model MTH MC MC R AR Refer to data sheet 2585 for detailed mounting options Options Model ST MC series Refer to data sheet 2585 for detailed mounting options Industry Inc Technologies Division Data MTH MC Industry Inc Technologies Division 1 Model MTH MC will produce 1 flash per second over the Input Voltage range Model MTH MC meets the required light distribution patterns defined in UL 1971 Model MTH MC is UL Listed for indoor use with a temperature range of 32 to 120 0 to 49 and maximum of 93 2 RH The effect of shipping and storage temperatures shall not adversely affect the performance of the when it is stored in the original cartons and not subjected to misuse or abuse Data ST MC Industry Inc Technologies Division for Ordering 500 650226 D E F L M O P R MTH Horn Multi Candela Agent Release Red 500 650224 B D E F G J N R X Multi Candela Agent Release Red Refer to data sheet 2585 for detailed mounting options This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2011 sheet dated 4 11 2

Related Files