Siemens MTH Notification Appliances Multi-tone Horn and Horn Strobe Appliances, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

s Series Notification Appliances Multi tone Horn Horn Strobe Appliances Indoor Outdoor Overview Series MTH appliances have In Out wiring terminations that accept 2 two to 18 American Wire Gauge AWG wires at each terminal Inputs are polarized for compatibility with standard reverse polarity type supervision Strobes can be synchronized using the Siemens DSC sync modules FS 250 panel XLS panel panel or PAD 3 power supply with built in sync protocol MTH Strobe models are available with Siemens MC multi Candela strobes with Candela settings at 15 30 75 110cd One alarm appliance with 8 eight selective signals to provide superior sound penetration for ambient and wall conditions with two field selectable sound output levels Audible and strobe can operate from a single NAC circuit or from separate NAC circuits with any of 8 eight audible sounds No additional trim plate required for flush mounting Code 3 Horn and Tone meet ANSI NFPA temporal pattern for standard emergency evacuation signaling UL Listed ULC Listed CSFM NYMEA Approved Complies with OSHA 29 Part 1910.165 Notification appliances shall be a Siemens Series MTH audible visual appliance or equivalent Notification appliance shall be electronic and use solid state components Electromechanical alternatives are not approved Each electronic appliance shall provide 8 eight field selectable alarm tones consisting of Horn Bell March Time Horn Code 3 Horn Code 3 Tone Slow Whoop Siren and HI LO Tone selection shall be by durable dip switch assembly and not clips or jumpers Multi tone Audible appliance shall be UL Listed under Standard 464 for Audible Signal Appliances The audible and the strobe shall be able to operate from a single NAC circuit while producing any these tones The appliance shall provide two output sound levels Standard and High dBA Anechoic The HIGH dBA Anechoic setting shall provide a minimum 5 dBA Anechoic increase in output at nominal voltage HIGH anechoic dBA measurement at 10 feet at the alarm horn setting shall be 99 dBA minimum Industry Inc Technologies Division Series Notification Appliances 2579 continued All models shall have provisions for standard reverse polarity type supervision and In Out field wiring terminals that accept 12 to 18 AWG wiring Combination audible visual appliances shall incorporate a Xenon flashtube enclosed in a rugged Lexan or equivalent with solid state circuitry Strobe portion of the appliance shall produce a flash rate of 1 flash per second over the Regulated Voltage Range The MTH strobe intensity shall be rated per UL Listed and under Standard 1971 for Signaling Devices the Hearing Impaired for field selectable 15 30 75 110 candela settings Strobe models shall incorporate circuitry for synchronized strobe flash and shall be designed for with the Siemens DSC sync modules FS 250 panel XLS panel or PAD 3 power supply built in sync protocol The strobes shall not drift out of synchronization at any time during operation The strobes shall revert to a non synchronized flash rate if the sync module or Power Supply should to operate i e contacts remain closed Strobe activation shall be via independent input or from the same input circuit as the audible Combination of audible visual appliances shall be installed indoors and may be surface or flush mounted Combination of audible visual appliances shall mount to standard electrical hardware requiring no trim plate or adapter Aesthetic appearance shall not have any mounting holes or screw heads visible when the installation completed Appliance shall be finished in a textured red color All notification appliances shall listed for Special Applications Strobes are designed to flash at 1 flash per second minimum over their Input Voltage Range Note NFPA 72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate 1 to 3 flashes per second All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971 Diagram In Inches Options Industry Inc Technologies Division Options cont Data 1 Strobe will produce 1 flash per second over the Input Voltage range This strobe horn model meets the required light distribution patterns defined in UL 1971 This model is UL Listed for indoor use with a temperature range of 32 to 120 0 to 49 and maximum humidity 93 2 RH The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance it is stored in the original cartons and not subjected to misuse or abuse All models are UL ULC Listed for indoor use with a temperature range of 32 to 120 0 to 49 These notification appliances are UL Listed as Application They are intended to be used only with Siemens maximum humidity of 93 appliance circuits Industry Inc Technologies Division Data continued Details for Ordering Including Mounting Options Agency Approvals Approvals MTH Horn Red MTH Horn White MTH Horn Multi Candela Red 500 650226 MTH Horn Multi Candela Agent Release Red MTH Horn Multi Candela White MTH Horn 180CD White 500 636080 MTH Horn 15CD 115V Red 500 636185 MTH Horn Hi Multi Candela Ceiling Weatherproof Red 500 636186 MTH Horn Hi Multi Candela Ceiling Weatherproof White 500 636187 MTH Horn Hi Multi Candela Weatherproof Red ULC FM CSFM X X X X X X X X X X X X X X WPS KIT WFPS X X X WPS KIT WFPS X X X WPS KIT WFPS X X X WPS KIT WFPS X X X 500 636188 MTH Horn Hi Multi Candela Weatherproof White listed approved Refer to catalog sheet 2585 for detailed mounting options This marketing catalog sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2009 sheet dated 7 07 1

Related Files