Siemens OPC Interface Specifications Version 5 1 SPC

File Preview
File Preview
Click below to download for free

File Data

Name siemens-opc-interface-specifications-version-5-1-spc-1692487053.pdf
Type PDF
Size 679.34 KB
Downloads

Text Preview

OPC Interface Specifications Version 5.1 No Infrastructure Infrastructure intrusion detection panel workbook describes the objects provided by the Siemens OPC Data Access Server to represent the control unit Model Model Item PresentValue Item Mode State Activate on OPC Item Mode Alarm Alarm Object Model defines the states and commands of all instances of that type In particular an Object Model virtualizes a class of physical objects devices and points the system by means of specific properties the OPC inteface the physical object is represented by an instance of an Object Model that contains PresentValue and Mode properties represented by two VT UI4 Items An approprate combination of these two values defines the real state of the instance result state When a command is issued it acts on the Mode property This results in changing the state of the instance identify the Object Model of each object instance open the CSV export file with a spreadsheet program and refer to the Object Model column See also Example of CSV File in section OPC Server of the online help DA Specifications V5.1 SPC xlsx 2 of 15 Object Specifications Infrastructure Model Area Area The area controls alarm mode Set Unset PartSet and associated zones Deinhibit Isolate Deisolate Test on OPC Item Mode Item PresentValue Item Mode State A B Status to Arm Ready Default Mode Default Mode Default Mode Set Set ON Fullset Ready OFF Unset Partially OFF Partially OFF DA Specifications V5.1 SPC xlsx 3 of 15 Object Specifications Infrastructure Model Door Door Access control door on OPC Item Mode Item PresentValue Item Mode State Default Mode Default Mode Controls Default Mode Open Too Long Too Long DA Specifications V5.1 SPC xlsx 4 of 15 Object Specifications Infrastructure Model Enet Node of ENETNODE Expanders on OPC Item Mode Item PresentValue Item Mode State Default Mode Default Mode DA Specifications V5.1 SPC xlsx 5 of 15 Object Specifications Infrastructure Model Mapping Gate outputs Intrusion alarming and control outputs mapped on physical output lines on OPC Item Mode Item PresentValue Item Mode State DA Specifications V5.1 SPC xlsx 6 of 15 Object Specifications Infrastructure Model Modem on OPC Item Mode Item PresentValue Item Mode State Default Mode Default Mode DA Specifications V5.1 SPC xlsx 7 of 15 Object Specifications Infrastructure Model PSU Supply Unit on OPC Item Mode Item PresentValue Item Mode State Default Mode Default Mode DA Specifications V5.1 SPC xlsx 8 of 15 Object Specifications Infrastructure Model System System General conditions related to the SPC intrusion system on OPC Item Mode Item PresentValue Item Mode State Default Mode Default Mode DA Specifications V5.1 SPC xlsx 9 of 15 Object Specifications Infrastructure Model Unidentified event Event with no corresponding object in the database on OPC Item Mode Item PresentValue Item Mode State Default Mode DA Specifications V5.1 SPC xlsx 10 of 15 Object Specifications Infrastructure Model User User authorized to operate the intrusion system on OPC Item Mode Item PresentValue Item Mode State Norm Duress DA Specifications V5.1 SPC xlsx 11 of 15 Object Specifications Infrastructure Model Xbus Open Closed loop X BUS provides connection to the unit expanders on OPC Item Mode Item PresentValue Item Mode State DA Specifications V5.1 SPC xlsx 12 of 15 Object Specifications Infrastructure Model Zone Zone Intrusion detector s protecting a part of the building on OPC Item Mode Item PresentValue Item Mode State Isolate Deisolate Inhibit Deinhibit Default Mode Default Mode Default Mode 6 Not Ready with NotReady active Alarm test mode DA Specifications V5.1 SPC xlsx 13 of 15 Object Specifications Infrastructure Model Event commands is not an Object Model but provides the read only information about the event states The related to the point can require the acknowledge silence unsilence and reset commands on OPC Item Mode Item PresentValue Item Mode State to offnormal to fault Alarm Power Too Long Open Fault DA Specifications V5.1 SPC xlsx 14 of 15 Infrastructure Switzerland Ltd Infrastructure Headquarters 1a Zug 41 58 724 2424 Siemens Switzerla

Related Files