Siemens PAD-5-CDC Expansion Board Installation manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-pad-5-cdc-expansion-board-installation-manual-6289571403.pdf |
---|---|
Type | |
Size | 1.35 MB |
Downloads |
Text Preview
PAD 5TM CDC Board Industry Inc Technologies Division Notice Notice specifications and availability subject to change without notice 2018 Copyright by Siemens Industry Inc is a trademark of Siemens Industry Inc reproduction dissemination and or editing of this document as well as of its contents and communication thereof to others without express are prohibited Offenders will be held liable for payment of damages All created by patent grant or registration of a utility model or design patent are by Industry Inc Technologies Division Fernwood Road Park NJ 07932 1 973 593 2600 2018 02 15 ID A6V101030366 en b Industry Inc Technologies Division security disclaimer security disclaimer products and solutions provide security functions to ensure the secure operation of building comfort fire security management and physical security systems The security functions on these products and solutions important components of a comprehensive security concept is however necessary to implement and maintain a comprehensive state of the art security concept that is cus to individual security needs Such a security concept may result in additional site specific preventive action ensure that the building comfort fire safety security management or physical security system for your site are in a secure manner These measures may include but are not limited to separating networks physically system components user awareness programs defense in depth etc additional information on building technology security and our offerings contact your Siemens sales or project We strongly recommend customers to follow our security advisories which provide information on the security threats patches and other mitigation measures http www siemens com cert en cert security advisories htm Industry Inc Technologies Division of Contents of Contents with CDC Expansion Board 5 5 6 Routing 7 the PAD 5 CDC 8 and Configuring the PAD 5 CDC 8 Instructions 9 Notes 10 Circuits 10 X211 X212 X213 and X214 Terminal Blocks 10 P2 Wiring 12 Programming Unit DPU Connection 12 Indicators 12 12 S401 Board RESET 12 Data 13 Detectors 14 Industry Inc Technologies Division PAD 5 with CDC Expansion Board PAD 5 CDC 1 PAD 5 with CDC Expansion Board Description Model PAD 5 CDC Expansion Board is a PAD 5 plug in board that allows detectors to be connected to the Fire Alarm system It provides four detection zones that can be wired Class A or Class B Each zone two wire photoelectric or ionization compatible smoke detectors and an number of normally open circuit closure devices The Siemens Fire Safety and beam detectors are also supported Relay bases remote lamps and audible may also be used with the PAD 5 CDC The PAD 5 CDC uses one address on P2 loop The PAD 5 CDC address is always one more than the PAD 5 main board it is plugged into The DPU is used to program the P2 address of the PAD 5 CDC are LED indicators for each zone as well as for the P2 interface and for the of the board The PAD 5 Main Board is capable of supporting a single board PAD 5 CDC or PAD 5 CLSA of the four programmable zones can be configured for the type of detectors on the zone or can be disabled if not used Detectors requiring 100mA zone limit may not be installed on zones that are configured for the 175mA current The current is automatically set by the Zeus programming tool based on the model selected Each loop is protected against short circuits and transient as required Do not use shorting devices on circuits with accessories on them The shorting will lower the zone voltage to a point where the accessories will not Any or all of the circuits may be programmed to operate with Alarm Verification allows the automatic verification of alarm conditions caused by smoke in order to prevent nuisance alarms Shorting devices may be used on zones that are configured for Alarm Verification a shorting device on an Alarm Verified zone is activated the zone will go into alarm bypassing the Alarm Verification sequence Industry Inc Technologies Division PAD 5 CDC 2 2 FEMALE 1 2 Typical Configuration Parts Supplied PCB Assembly inside the antistatic bag Hardware kit inside the polybag screws 4 40 x long includes 2 standoffs 4 40 x 13 16 long 1 standoff male female hex 5 16 long 6 32 thread 4 terminal blocks 4 position 1 installation instructions 4 4.7K Carbon Film EOL Resistors P N 140 820188 50uF 50V Alum Elect EOL Capacitors P N 100 115588 THE BOARD the daughter bypass board that is factory installed on X901 location shown Figure 2 before attaching the PAD 5 CDC board to the PAD 5 MB the mounting screw screw next to expansion connector X900 do not the screw will be reused the two 13 16 standoffs provided unto the backbox as shown on 2 the male female standoff to the PAD 5 MB as shown in Figure 2 in the board as shown in Figure 2 Align the two connectors from the PAD 5 CDC the two connectors on the main board the two 13 16 screws provided to secure the board in place screw to the PAD 5 CDC board and the male female standoff as shown in 2 Industry Inc Technologies Division PAD 5 CDC Routing is recommended that the printed circuit boards be removed for any procedure that may dust metal shavings grease or any such matter that may affect the circuit boards parts All field wiring and connections to the PAD 5 MB must be disconnected and must be disconnected before removing fasteners and removing the board assembly the enclosure Wire Routing high voltage and non power limited wiring must be kept separate from power limited wir A separation must be maintained with high voltage and non power limited wiring in separate conduit openings from power wiring avoid induced noise transfer of electrical energy from one wire to another keep input isolated from high current output and power limited wiring Improper wiring installation cause improper operation Avoid pulling one multi conductor cable for the entire system separa