Siemens Periphery board (250p), Periphery board (500p)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-periphery-board-250p-periphery-board-500p-1546709328.pdf |
---|---|
Type | |
Size | 2.56 MB |
Downloads |
Text Preview
FCI2016 U1 FCI2017 U1 boards 3.1 Infrastructure notice notice specifications and availability subject to change without notice reproduction dissemination and or editing of this document as well as of its contents and communication thereof to others without express are prohibited Offenders will be held liable for payment of damages All created by patent grant or registration of a utility model or design patent are by Industry Inc Infrastructure Fernwood Road Park NJ 07932 1 973 593 2600 2020 08 19 ID A6V10315038 g en Siemens Industry Inc 2011 46 of contents board 250p FCI2016 input power and battery Wiring power supply input and battery Power supply terminal block 1 Power supply 2 terminal block jumper Power supply 2 on off Voice supply 24 Battery terminal circuits Wiring the NAC circuits terminal block NAC 1 class A NAC 1 1 class B NAC 1 2 B jumper ENABLE DISABLE DEGRADED MODE for NAC 1 A or NAC 1 1 class B jumper ENABLE DISABLE DEGRADED MODE for NAC class B X605 X606 Jumper NAC 1 class A B jumper DEGRADE ALARM SILENCEABLE follower input Wiring Bell follower terminal block DC output Wiring Auxiliary output terminal block Wiring Relay terminal block circuits circuit driver 1 circuits 1 and 2 Wiring terminal block detector circuit 1 terminal block detector circuit 2 Indicators Reset Buttons S100 RESET periphery board Technical data board 500p FCI2017 input power and battery Wiring power supply input and battery 46 Power supply terminal block 1 Power supply 2 terminal block jumper Power supply 2 on off Voice supply 24 Battery terminal circuits Wiring the NAC circuits terminal block NAC 1 class A NAC 1 1 class B NAC 1 2 B jumper ENABLE DISABLE DEGRADED MODE for NAC 1 A or NAC 1 1 class B jumper ENABLE DISABLE DEGRADED MODE for NAC class B X605 X606 Jumper NAC 1 class A B jumper DEGRADE ALARM SILENCEABLE follower input Wiring Bell follower terminal block DC output Wiring Auxiliary output terminal block Wiring Relay terminal block circuits circuit driver 1 circuits 1 and 2 and circuit driver 2 cir 3 and 4 Wiring and X1801 terminal block detector circuits 1 and 3 and X1802 terminal block detector circuits 2 and 4 Indicators Reset Buttons S100 RESET periphery board Technical data Statement 46 board 250p FCI2016 Periphery board 250p FCI2016 Description periphery board 250p FCI2016 is used for fire control panels and voice alarm fire panels with max 252 device addresses The purpose of the periphery board is provide means for supervising and controlling various peripheral devices such as and notification devices and providing power for the entire panel There is a core on the periphery board that is isolated from the rest of t