Siemens PLM-35 Power Limiting Module, Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name siemens-plm-35-power-limiting-module-data-sheet-4315978026.pdf
Type PDF
Size 876.53 KB
Downloads

Text Preview

Data AND ENGINEER SPECIFICATIONS 3TM Limiting Module PLM 35 Allows power limited wiring for appliance circuits Compact modular design Easy installation UL 864 9th Edition Listed Overview Power Limiting Module Model PLM 35 from Fire Safety allows the use of power fire protective signaling circuit conductors operate on 24VDC NACs added technical incentive for installing Model into a fire alarm control panel FACP is alarm initiating circuits as well as the 24VDC NACs can be installed in the same enclosure Model PLM 35 can be used with the NACs in all Siemens Fire Safety FACPs System 3 Fire systems and installations Model PLM 35 meet power limiting outlined in the National Electric NEC PLM 35 converts 24VDC electrical non circuits into a power limited circuit the respective FACP Industry Inc Technologies Division CSFM and NYC Fire Department Approved limited circuitry of energy contains a non current limiting device The power module is connected in series with the non power limited energy source Wiring Diagram section within this for more information PLM 35 may be used with either A Z or B Style W circuits conversion of a non power limited 24VDC into a power limited circuit shall be made by use of a Siemens Fire Safety Model PLM 35 unit which shall be connected in series with electrical non power limited energy source contain a non replaceable over current This power limiting device shall be inside of the respective FACP Limiting Module 3182 continued power limited module shall provide the of using either A Style Z or B W circuits unit shall be UL 864 9th Edition Listed and Humidity Range Power Limiting Module is UL 864 9th Listed for indoor dry locations within a range of 120 3 49 2 to 0 2 and a relative humidity of at a temperature of 90 3 32 2 for Ordering Refer to Installation Instructions P N 315 093495 Power Limiting Module Wiring Diagram A Style Z Wiring Both negative supervisory lines must be separately fused to the PLM 35 terminals as follows Terminal 3 Terminal 7 PLM 35 PLM 35 1 1 1 1 B Style W Wiring Connect Terminal 1 of Model PL 35 to the following Model CP 35 Terminal 35 Model AE 30U Terminal 3 Model CP 2ER Terminal or TB2 This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions s Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www SBT Siemens com FIS in U S A Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2012 sheet dated 12 04 1

Related Files