Siemens RM-30U RM-30RU Releasing Device Modules, Wiring Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Wiring Instructions RM 30U RM 30RU Device Modules Releasing Device Modules Models RM 30U and are designed to operate and supervise valves or relays used for release of systems and to operate and supervise used for door closing opening or fan control RM 30U and RM 30RU are functionally the except that the RM 30RU incorporates three series resistors that are used to adjust the of the circuit to compensate for varying of solenoids logic and subsequent activation of the are governed by appropriate zone and modules in the System 3 control panel modules are suitable for continuous duty when with continuous duty solenoids input signals are required for activation of these and a release takes place when a high signal is present on both of the input terminals input signals are compatible with the outputs from the System 3 zone and control All agent release logic time delays etc performed ahead electrically of the RM 30U by utilizing such System 3 modules as ZU 35 Module PM 31 Program Matrix TL 30U Timer SR 32 Relay Module The separate release input terminals extend the modules versatility reduces the load on the 10 conductor system bus Safety circuit disconnect switch is provided to deactivate module during servicing of the system When the is in the off position a local supervisory LED be illuminated and an audible will sound modules are provided with a yellow LED trouble to show an open release circuit condition the system is not in alarm The LED indicator be lamp tested from the control panel In addition wiring is monitored by the control panel for ground The module is also provided with a LED buzzer and silence switch As above activating the disconnect switch the supervisory signal When there is no condition and the supervisory silence is in the silence condition a trouble signal is The modules are placement supervised a trouble signal on removal from the Information current requirement supervisory 6mA 24VDC energized 1.5A maximum 24VDC line resistance 3 ohms for typical load Building Technologies Inc Fernwood Road Park New Jersey 07932 315 085100 14 Building Technologies Ltd Kenview Boulevard Ontario L6T 5E4 Canada PLACES TABLE 1 FUSE POWER NOTE 1 OHMS MAX LINE RESISTANCE OF DEVICE CIRCUIT WIRES CONNECTED OPERATED RATED 6 VDC EACH OTHER APPROVED LOAD NOTES 1 AND 2 INPUT VDC FULLWAVE RECTIFIED MAX FROM TERMINAL 42 TERMINAL 1 OR 7 TL 30U TERMINAL 3 CONNECTION MUST MADE TO PROVIDE POWER ALARM ONLY ACTIVATED INPUT VDC SHOWN OR EQUIVALENT UNFILTERED MAX FROM CP 35 B CONNECTED RELEASING DEVICE CIRCUIT SHOWN IN SUPERVISORY CONDITION VDC 5mA VDC REGULATED 1.5mA MAX FUSE POWER NOTE 1 OHMS MAX LINE RESISTANCE OF DEVICE CIRCUIT WIRES INPUT VDC RECTIFIED MAX FROM TERMINAL 42 TERMINAL 1 OR 7 TL 30U TERMINAL 3 CONNECTION MUST MADE TO PROVIDE POWER ALARM ONLY SOLENOID OTHER APPROVED LOAD NOTE 1 AND TABLE 2 ACTIVATED INPUT VDC FULLWAVE UNFILTERED 21mA MAX FROM CP 35 SHOWN OR EQUIVALENT B CONNECTED RELEASING DEVICE CIRCUIT SHOWN IN SUPERVISORY CONDITION VDC 5mA VDC REGULATED 1.5mA MAX for RM 30RU Operating solenoids relay or other approved loads operate a 24 VDC source Use Battery Transfer Modules BC 35 DC Program Plug JP D in P2 of the CP 35 for RM 30U Operating solenoids relay or other approved loads operate a 24 VDC source Use Battery Transfer Modules BC 35 DC Program Plug JP D in P2 of the CP 35 The RM 30RU Releasing Device Module may be used to up to four 6 VDC solenoids Table 1 describes the acceptable combinations of solenoids and or resistors other combination not described in Table 1 is not Solenoid supervised for open only All terminals are non power limited For wiring instructions to the EB 31 32 33 35 Installation and Power Limited Instructions P N 315 093680 If power limited wiring desired use the PLM 35 P N 315 093495 For releasing diagram connections of RM 30RU refer to 315 049675 The abort switch can have precedence the manual release function or the manual release can precedence over the abort switch For NFPA 13 Automatic Water Control Valve Release use electric solenoid valve For NFPA 2001 Releasing Service use only an approved actuator See Table 2 Solenoid supervised for open only All terminals are non power limited For wiring instructions to the EB 31 32 33 35 Installation and Power Limited Instructions P N 315 093680 If power limited wiring desired use the PLM 35 P N 315 093495 For releasing diagram connections of RM 30U refer to P N The abort switch can have precedence over manual release function or the manual release can precedence over the abort switch to the System 3 Pre Action Sprinkler Control Diagram P N 315 091776 for an FM approved configuration Approval THE RELEASING DEVICE MUST BE AN FM APPROVED ELECTRIC SOLENOID VALVE FOR AN AUTOMATIC CONTROL VALVE RELEASE 315 085100 14

Related Files