Siemens S-HQ 8 Supervised Speakers and Speaker Strobes, Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-s-hq-8-supervised-speakers-and-speaker-strobes-data-sheet-9324815706.pdf |
---|---|
Type | |
Size | 1.58 MB |
Downloads |
Text Preview
s Sheet Safety Products Appliances 8 Supervised Speakers and Speaker Strobes Application Indoor Strobe Overview High efficiency design for maximum output at minimum wattage across a frequency range of 400 to 4000Hz S HQ 8 Inch Speakers Speaker Strobes are designed for multiple power requirements high dBA output at each power tap and offers a choice of field selectable taps 1 4W to 8W for either 25.0VRMS or 70.0VRMS audio systems S HQ 8 Inch Speaker portion has field selectable taps from 1 8W to 8W for 25 or 70 VRMS operation The strobes portion of the Series appliances can be synchronized when used with any of the following 50 point 252 504 point addressable fire safety systems FireFinder XLS control panels Siemens Dual Sync Control Modules Model DSC series with built in sync protocol Siemens PAD series of NAC Extenders Siemens Series meets the requirement for low frequency signal tone described in the section for Determination of Low Frequency Signal Format the Standard for Audible Signal Appliances per UL464 when used with One 1 Amplifier Card Model VCI2001 U1 with Siemens 252 point 504 point addressable FACPs One 1 Booster Amplifier Model EBA200x Series with Siemens 252 point 504 point addressable FACPs One 1 40W Zone Amplifier Card Model ZAC 40 with FireFinder XLSV Fast installation with In Out screw terminals using 12 to 18 AWG wires Ceiling mount models are available with field selectable Candela settings of 15 30 75 95cd Speaker impedance 8 ohms Round metal 12 inch grille with white powder coated finish Magnet weight 9.5 oz 269g Compatible with DC circuit supervision ADA NFPA ANSI compliant Complies with OSHA 29 Part 1910.165 UL Listed ULC Listed 7320 0067 0243 and 7320 0067 0255 Approved Speaker appliances shall be Siemens Series Speakers and speaker strobe appliances be Siemens Series S HQ Speaker Strobes or approved equals Speakers shall be UL Listed for indoor use under Standard 1480 for Fire Protective Service and equipped with strobes shall be listed for indoor use under UL Standard 1971 for Devices for the Hearing Impaired Speaker with strobes shall be certified to meet the requirements of FCC Part 15 Class B Industry Inc Technologies Division Notification Appliances 2586 continued Strobe intensity where multi Candela appliances are specified shall have field selectable settings All models shall have listed sound output of up to 93 dB at 10 feet with 8 Watts of source power and shall be rated per UL Standard 1971 for 15 30 75 95cd Listed frequency response of 400 to 4000Hz Frequency Response 200Hz 15000Hz 400Hz 4000Hz UL The strobe portion when synchronization is required shall be compatible when used with any of the following 50 point 252 504 point addressable fire safety systems FireFinder XLS control panels Siemens Dual Sync Control Modules Model DSC series with built in sync protocol Siemens PAD series of NAC Extenders Siemens Series meets the requirement for low frequency signal tone per UL464 when used with One 1 Amplifier Card Model VCI2001 U1 with Siemens 252 point 504 point addressable FACPs One 1 Booster Amplifier Model EBA200x Series with Siemens 252 point 504 point addressable FACPs One 1 40W Zone Amplifier Card Model ZAC 40 with FireFinder XLSV Strobe portion of the appliance shall produce a flash rate of one 1 flash per second and incorporate a Xenon flashtube enclosed in a rugged Lexan lens The strobes shall not drift out of synchronization at any time during operation Speaker strobe appliances shall be designed for indoor surface or flush mounting Speaker shall be mounted to round metal 12 grille with a white powder coated finish for indoor use All inputs shall employ terminals that accept 12 to 18 AWG wire sizes The strobe portion of the appliance shall be of low current design All speaker and speaker strobe appliances shall be listed for Special Applications Strobes are designed to flash at 1 flash per second minimum over their Input Voltage Range Note NFPA 72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a rate of 1 to 3 flashes per second All candela ratings for Series were tested to the voltage limits of 16.0 33.0 Volts for 24V models using filtered or unfiltered full wave rectified FWR voltage Outside voltage was not applied outside of this range Diagrams In Inches Industry Inc Technologies Division Diagrams continued Data Series Ceiling Mount Strobes Only Ratings AMPs Voltage Range 15cd 16.0 33.0VRMS 16.0 33.0VRMS Listed Models and Ratings RMS Current Per UL Per UL 1971 and UL 1480 Voltage Application VDC VRMS 33.0 30 75 95 Series Ceiling Mount Speakers Only Listed Models and Ratings at 10 Feet Watts 1 4 1 2 1 81 84 87 90 93 81 84 87 90 93 All models available in red or white 1 Strobe will produce 1 flash per second over Regulated Voltage range The strobe meets the required light distribution as defined in UL 1971 Models are UL Listed for indoor use with a temperature of 32 to 120 0 to 49 and maximum of 85 RH A 10pF blocking capacitor for DC supervision of audio lines the FACP is factory wired in series with the speaker input The maximum supervision voltage is 33 VDC frequency range of speakers is 400 4000Hz effect of shipping and storage temperatures shall not adversely affect performance of the appliance when it is stored in the original cartons is not subjected to misuse for Ordering Including Mounting Options Agency Approvals Agency Approvals 500 636108 S HQ Series 8 inch Multi Candela Ceiling Speaker White Series 8 inch Ceiling Speaker White Series 8 inch Ceiling Speaker Back Box Series 8 inch Speaker Support Bridge ULC CSFM DD DD DD DD listed approved Refer to data sheet 2585 detailed mounting options Industry Inc Technologies Division This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www usa Siemens com Fire in U S A Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA 2015 sheet dated 3 2015 3