Siemens S-series License Keys for Desigo Fire Safety, Data Sheet, data sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-s-series-license-keys-for-desigo-fire-safety-data-sheet-data-sheet-8146352079.pdf |
---|---|
Type | |
Size | 833.49 KB |
Downloads |
Text Preview
Desigo Fire Safety S2 S3 License Keys for use with the Viewer Tool and or Communication Protocol FCA2033 A1 FCA2034 A1 FCA2035 A1 Engineer Specifications The S1 license key Model FCA2033 A1 allows for monitoring and control between a Desigo 504 point addressable fire alarm control FACP and a personal computer PC 252 point FIRE only panel Model FC2025 504 point FIRE only panel Model FC2050 252 point Intelligent Voice Communication addressable panel Model FV2025 504 point IVC only panel Model FV2050 The S2 license key Model FCA2034 A1 is a output and is used for monitoring purposes by a third party system for life safety objects The S3 license key Model FCA2035 A1 is a license key that allows for virtual and control as well as for distribution BACnet monitoring only communications Each license key fits into a diminutive attached to the back end of a system operating unit Standard Operating Unit Model FCM2018 U2 Operating Unit with LED Model FCM2019 U2 S series keys are only operational on tablet and on Windows v7 or later O S UL864 UL2017 UL2572 CAN ULC S559 13 Listed CSFM NYC Fire Department Products Overview License Key S1 license key Model FCA2033 A1 is used as a means for making simple highly integral FACP functions remotely occur in real time Through the use an installed remote viewer on a tablet personal computer PC an end user the functionality to monitor and if necessary have remote control of system events originating from a Desigo Fire Safety 252 504 point FACP a control mode is activated the S1 license key makes it possible for the to virtually perform basic or vital system functions in the same manner as if the end user was actually in front of the panel that to be in event command mode License Key S2 license key Model FCA2034 A1 is exclusively used as a BACnet and is used for monitoring only purposes by a third party system for life safety objects License Key S3 license key Model FCA2035 A1 is a combination license offering full monitoring and control as the Model FCA2033 A1 S1 license key as equivalent to the Model FCA2034 A1 S2 key distribution of providing the BACnet as Specifications order for monitoring and control of a Desigo FACP to occur via remote view a Siemens Ethernet Switch Model FN2012 U1 for FIRE only Desigo or a Model VCA2002 A1 Card Cage for Desigo IVC FACPs must be S series license keys fit into a diminutive metal hasp attached to the end of a Desigo Fire Safety operating unit Standard Operating Unit Model FCM2018 U2 Operating Unit with LEDs Model FCM2019 U2 S2 S3 Key 1 key can be to a hasp on the back of Unit Technologies Division Use of a Remote Viewer in Control Mode is not Listed as a required annunciator in installations Sheet 6820 usa siemens com desigo fire safety Viewer a laptop PC Fire Safety FACP for mid scale applications order keys Specifications continued four digit personal identification number PIN is required all S series prevent access to the Desigo Fire Safety FACP conditions such as and Ground Fault are vividly on the end user PC monitor via simulated from the front end liquid crystal display LCD of the active FACP remote display of the panel front end LCD screen in real time on the laptop PC from the Desigo tab of the custom configuration software tool or the Desigo View standalone tool and S3 License Keys for the Remote Viewer have the of using a commercially available wireless router for between the tablet personal computer and the panel dimensions for each type of license key are size 0.2 0.51 cm H 1.6 cm W weight of each license key is about 5 oz 142 g license keys are FM 3010 CSFM and FDNY 6104 Approved Use of a Remote Viewer in Control Mode is not Listed as a required annunciator in installations and Humidity Range are UL Listed for indoor dry locations a temperature range of 120 3 49 2 32 3 0 2 and a relative humidity of at a temperature of 90 3 32 2 Documentation SHEET NUMBER OPERATING UNITS 252 POINT PANEL 504 POINT PANEL INTELLIGENT VOICE IVC SYSTEM for Ordering TYPE S54400 P154 A1 S54400 P155 A1 S54400 P156 A1 S1 Key remote access remote view operation S2 Key output only S3 Key for access view operation output The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer Fire Safety Industry Inc Technologies Division Fernwood Road cid 127 Florham Park NJ 07932 973 593 2600 2018 Supersedes sheet dated 3 2016 3