Siemens SBGA-34 Audible Base for HFP 87 series and Cerberus PRO Intelligent Detectors, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Detection Bases Base for and Cerberus PRO Intelligent Detectors SBGA 34 Works with Models and Cerberus AND ENGINEER SPECIFICATIONS Sheet Intelligent detectors Audible tones American National Standards Institute ANSI Temporal 3 pattern ANSI Temporal 4 pattern Temporal 4 pattern Carbon Monoxide CO code compliant tone produces a continuous 2400 Hz tone can also follow the Siemens fire alarm control panel FACP appliance circuit NAC output Provides audible signals for FIRE Temporal 3 and CO 4 without the need for two 2 separate or audible sounder devices Pre wire mounting plates fit various sizes System compatible with Cerberus PRO Models FC901 FC922 and FC924 FACPs FireFinder XLS FACPs FireSeeker FS 250 FACPs Siemens PAD series NAC Extenders Overview Model SBGA 34 Audible Base from Siemens Fire is an intelligent detector base consisting of a Siemens Series base which combines circuitry for Cerberus PRO as well as Models and detectors Each Model SBGA base also contains an audible sounder device SBGA 34 which is used with the polarity Siemens Models 8710 8712 8713 HFP 11 and HFPT 11 intelligent detectors also with the Cerberus PRO Models OH921 HI921 OOH941 and OOHC941 intelligent detectors Models SFP 11 SFPO 11 and SFPT 11 detectors are for use exclusively in Canada applications of each Model SBGA 34 detector include all vicinities that normally would require audible annunciation such as hotels motels condominiums dormitories guest suites residential boards and care facilities SBGA 34 can be used with the following Siemens systems FireFinder XLS Cerberus PRO FireSeeker and PAD series NAC Extenders PRO Safety Security Products for infrastructure SBGA 34 View SBGA 34 View Replaces single multiple station smoke alarms residential occupancies when used with Siemens fire systems Multiple event driven tone outputs Generates up to 85dbA signals at 10 feet 3.1 m UL268 464 Listed ULC S525 Listed CSFM Listed SBGA 34 consists of a standard Siemens Fire Series base combined with supportive circuitry Cerberus PRO as well as Models and detectors Each Model SBGA 34 base also contains audible sounder device field wiring terminates at two 2 of the 4 four position blocks located on the back of Model SBGA 34 Model SBGA 34 contains a pre wired audible piezo device that produces a signal up to 85dBA at 10 ft for localized annunciation different configurations can provide audible signal power to Model SBGA 34 See the Wiring Diagram P N A6V10383428 in the and Operation Manual for Model SBGA 34 in the shipment of each unit a fire system is in Supervised mode the polarity of power to all Model SBGA 34 detectors is in reversed state resulting in zero current flow to each base Model SBGA 34 bases are capable of sounding individually or in any combination upon the system program and FACP SBGA 34 Audible Base continued an Alarm command is reported to the FACP power to Model SBGA 34 detectors reverses polarity and there is audible sound The system may then selectively Model SBGA 34 under automatic control to audible installation of a jumper wire between Terminals 3 and 4 Model SBGA 34 changes the tone output from to Model SBGA 34 audible base is UL268 UL464 as well as ULC S525 Listed for Canada Detectors Model SBGA 34 audible base is compatible with following Siemens Intelligent detectors Instructions Number A6V10324661 Models SFP 11 SFPO 11 and SFPT 11 detectors are for use exclusive to Canada customers Data SBGA 34 is compatible with Siemens Models and Cerberus PRO intelligent detectors smoke detectors used with Model SBGA 34 are subject the maximum 30 ft center spacing 900 sq ft as to in the National Fire Protection Association 72 This spacing however is based on ideal namely smooth ceiling no air movement no physical obstructions between the fire source and detector aforementioned center spacing format should be to as a guide for detector installation layout Do mount detectors in areas close to ventilating or air outlets Exposed joists or beamed ceilings may effect safe spacing limitations for detectors is mandatory for NFPA 72 guidelines and good judgment be applied to detector placements spacing Notes SBGA 34 is a smoke detector supplementary device combining and audible device functions Model SBGA 34 meets the requirements for smoke alarms as specified in UL217 and Multiple Station Smoke Alarms used in conjunction with listed compatible equipment Model may be used in lieu of single multiple station smoke to achieve enhanced system level functionality used to follow the NAC tone pattern Model SBGA 34 must be to tone and the system to which it is connected must be accordingly for the desired application allows Model SBGA 34 to transition from one tone to another pattern e g from 4 to 3 Proper must be met and synchronization with the NAC zone for which is connected can occur Data Cross Cable 31 VDC for Special Applications 22 AWG Wire Gauge Loop 0.6mA Power Supply 0mA Loop 2.8mA Power Supply 56mA Current Audibility Measurements at 10 ft 3.1 m for Ordering Detector Base for Siemens Safety Intelligent Detectors CerberusTM PRO Industry Inc Building Technologies Div Fernwood Road Florham Park NJ 07932 973 593 2600 Fax 908 547 6877 www USA Siemens com Cerberus PRO The information contained in this data sheet document is intended only as a summary and subject to change without notice The devices described here have specific instruction sheets that various technical limitation and liability information of these instruction sheets and the General Product Warning and Limitations document also contains important information are provided with the product and are available from Manufacturer contained in these documents should be consulted before specifying or using the For further information or assistance concerning particular problems contact the Manufacturer Technologies Division Fire Safety in U S A 2013 New Issue 0

Related Files