Siemens SBGA-34 Audible Base for ‘HFP’ series and Desigo Intelligent Detectors (for Canada), Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Data Sheet Safety Security Products Bases Base for and Desigo Intelligent Detectors SBGA 34 Works with Model detectors and Desigo Fire AND ENGINEER SPECIFICATIONS Intelligent detectors Audible tones American National Standards Institute ANSI Temporal 3 pattern ANSI Temporal 4 pattern Temporal 4 pattern Carbon Monoxide CO code compliant tone produces a continuous 2400 Hz tone can also follow the Siemens fire alarm control panel FACP appliance circuit NAC output Provides audible signals for FIRE Temporal 3 and CO 4 without the need for two 2 separate or audible sounder devices Pre wire mounting plates fit various junction box sizes System compatible with Desigo Fire Safety Models FC2025 and FC2050 FACPs FireFinder XLS FACPs FireSeeker FS 250 FACPs Siemens PAD series NAC Extenders Overview Model SBGA 34 Audible Base from Siemens Fire is an intelligent detector base comprising of a Siemens Series base which combines circuitry for Desigo Fire Safety and Model detectors Each Model SBGA 34 base also an audible sounder device SBGA 34 is used with the polarity insensitive Models HFP 11 HFPO 11 and HFPT 11 detectors and functions with the Desigo Fire Models FDO421 FDT421 FDOT421 FDOOT441 FDOOTC441 intelligent detectors Models SFP 11 SFPO 11 and SFPT 11 detectors are for use exclusively in Canada applications of each Model SBGA 34 detector include all vicinities that normally would require audible annunciation which would include motels apartments condominiums dormitories suites day care residential boards and care SBGA 34 can be used with the following Siemens systems FireFinder XLS Desigo Fire Safety FS 250 and PAD series NAC Extenders Canada Limited View View Replaces single multiple station smoke alarms residential occupancies when used with Siemens fire systems Multiple event driven tone outputs Generates up to 85dbA signals at 10 feet 3.1 m UL268 464 Listed ULC S525 Listed CSFM Listed SBGA 34 consists of a standard Siemens Fire Series base combined with supportive for the Desigo Fire Safety and Model Each Model SBGA 34 base also houses an sounder device field wiring terminates at two 2 of the 4 four terminal blocks located on the back of Model Model SBGA 34 contains a pre wired audible piezo device that produces a signal up to 85dBA at 10 3.1m for localized annunciation different configurations can provide audible circuit power to Model SBGA 34 See the Wiring Diagram P N A6V10383428 in the and Operation Manual for Model SBGA 34 in the shipment of each unit a fire system is in Supervised mode the polarity of power to all Model SBGA 34 detectors is in reversed state resulting in zero current flow to each base SBGA 34 Audible Base 6157C continued an Alarm command is reported to the FACP to all Model SBGA 34 detectors reverses and there is no audible sound The system then selectively command Model SBGA 34 automatic control to become audible Model SBGA 34 bases are capable of sounding individually or in any combination upon the system program and FACP installation of a jumper wire between Terminals 3 4 of Model SBGA 34 changes the tone output to Model SBGA 34 audible base is UL268 UL464 as well as ULC S525 Listed for Canada Detectors Model SBGA 34 audible base is compatible with following Siemens Intelligent detectors Instructions Number A6V10324655 A6V10324657 Models SFP 11 SFPO 11 and SFPT 11 are approved for use in Canada Data SBGA 34 is compatible with Siemens Model and Desigo Fire Safety intelligent smoke detectors used with Model SBGA 34 are to the maximum 30 ft center spacing sq ft as referred to in the National Fire Association Standard 72 This spacing is based on ideal conditions namely ceiling no air movement and no physical between the fire source and the aforementioned center spacing format should be to as a guide for detector installation layout not mount detectors in areas close to ventilating or outlets Exposed joists or beamed may also effect safe spacing limitations for is mandatory for NFPA 72 guidelines and good judgment be applied to detector and spacing Notes SBGA 34 is a smoke detector supplementary device detector base and audible device functions Model SBGA meets the audibility requirements for smoke alarms as specified UL217 Single and Multiple Station Smoke Alarms used in conjunction with listed compatible equipment Model may be used in lieu of single multiple station smoke to achieve enhanced system level functionality used to follow the NAC tone pattern Model SBGA 34 must be to tone and the system to which it is connected must be accordingly for the desired application allows Model SBGA 34 to transition from one tone to another pattern e g from 4 to 3 Proper must be met and synchronization with the NAC zone for it is connected can occur Data 31 VDC for Special Applications Design 22 AWG Wire Gauge Loop 0.6mA Power Supply 0mA Loop 2.8mA Power Supply 56mA Audibility Measurements at 10 ft 3.1m for Ordering Detector Base for Siemens Safety Intelligent Detectors This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Canada Limited www USA Siemens com Desigo Fire Safety Ltd Safety Kenview Boulevard Ontario 5E4 Canada 905 799 9937 905 799 9858 2013 Issue 0

Related Files