Siemens SE Notification Appliances Speaker and Speaker Strobes, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

s Sheet Safety Products Appliances Speaker and Speaker Strobes Indoor Strobe Strobe Overview Strobe portion of Siemens Series appliances can be synchronized using the Siemens 252 point and 504 point addressable fire alarm control panels FACPs as well as with FireFinder XLS V FACPs PAD 3 or PAD 4 NAC Extenders Siemens dual sync control DSC modules Ceiling mount models are available with field selectable Candela settings of 15 30 75 95cd with field selectable High Candela settings 115 177cd Wall mount speaker strobe models with field selectable Candela settings of 15 30 75 110cd with field selectable High Candela settings 135 185cd Mounts to 4 10.2 cm square 2 1 8 5.4 cm deep back box An Optional Extender SPEXT can be used for mounting ceiling only appliances to 4 10.2 cm backboxes No extension ring is required for Siemens Series appliances used in wall mount applications High efficiency design for maximum output at minimum across a frequency range of 400 to 4,000 Hz Field selectable taps for 25 or 70 VRMS operation from 1 8 Watt up to 2 Watts Fast installation with In Out screw terminals using 12 to 18 AWG wires Snap on grille cover with non visible mounting screws Complies with OSHA 29 Part 1910.16 Listed ULC Listed U LC for speaker only ceiling mount applications 3150 and CSFM Approved 7125 0067 0254 Fire Alarm Devices For The Hearing Impaired Speakers Series Notification Appliances 2580 Industry Inc Technologies Division Speaker appliances are Siemens Series Speakers and the speaker strobe appliances Siemens Series Speaker Strobes or approved equals Speakers are UL Listed under Standard 1480 for Fire Protective Service and speakers with strobes are listed under UL Standard 1971 for Emergency Devices the Hearing Impaired Siemens Series wall mount appliances each have a listed sound output of up to dBA at 10 feet 3 meters and a listed frequency response of 400 to 4,000 Hz All ceiling mount models have listed sound output of up to 87 dB at 10 feet 3 meters a listed frequency response of 400 to 4,000 Hz Speaker portion is designed for a field selectable input of either 25 or 70 VRMS selectable power taps from 1 8 Watt to 2 Watts Speakers are comprised of a sealed back construction All inputs accept terminals that use 12 to 18 AWG wire sizes Strobe intensity where multi Candela appliances are specified have settings and are rated per UL Standard 1971 for 15 30 75 110cd wall mount 135 185cd wall mount high Candela 15 30 75 95cd ceiling mount 115 177cd ceiling mount high Candela Manual selector switch for setting the candela is tamper resistant The strobe portion when synchronization is required is compatible via the use of the Siemens 252 point and 504 point addressable fire alarm control panels FACPs as well as with FireFinder XLS V FACPs PAD 3 or PAD 4 NAC Extenders Siemens dual sync control DSC modules The strobes do not drift out of synchronization at any time during operation The strobes will revert to a non synchronized flash rate if the sync module Power Supply should fail to operate i e contacts remain closed Wall mount speaker and speaker strobe appliances are designed for indoor flush to 4 10.2 cm square 2 1 8 5.4 cm electrical boxes without for an extension ring or surface mounting Ceiling mount speaker strobe Series appliances are designed for indoor flush mounting Speaker and speaker strobe incorporate a speaker mounting plate with a snap on grille cover finish on each grille for Siemens Series speakers and speaker strobes is white or red All speaker and speaker strobe appliances are listed for Special Applications are designed to flash at 1 flash per second minimum over their Input Voltage Range Notes NFPA 72 specifies a flash rate of 1 to 2 flashes per second Guidelines specify a flash rate of 1 to 3 flashes per second candela ratings represent minimum effective Strobe intensity based on UL Standard 1971 Industry Inc Technologies Division Diagram Strobe Mount Only Strobe Mount Only or Ceiling Mount In Inches Options Data SEC Series Speakers Listed Models and Ratings at 10 Feet Watts 79.5 82.5 85 88 79.5 82.5 85 88 79.5 82.5 85 88 79.5 82.5 85 88 All models available in red or white All models are UL Listed for indoor use with a range of 32 to 120 0 to 49 maximum humidity of 85 RH is rated per UL Standard for Speaker Appliances range of speakers is 400 4,000Hz SEC Series Speakers Voltage Wattage Connection Chart Industry Inc Technologies Division Series Ceiling Mount Strobes Ratings AMPs Voltage 16.0 33.0VDC 16.0 33.0VRMS 0.117 RMS Current with Hi dBA Setting Series Ceiling Mount Strobes Ratings AMPs RMS Current with Hi dBA Setting Voltage 16.0 33.0VDC 16.0 33.0VRMS Series Wall Mount Strobes Ratings AMPs Voltage 16.0 33.0VDC 16.0 33.0VRMS RMS Current with Hi dBA Setting Series Wall Mount Strobes Ratings AMPs RMS Current with Hi dBA Setting Voltage 16.0 33.0VDC 16.0 33.0VRMS for Ordering Including Mounting Options Agency Approvals Agency Approvals ULC FM CSFM SE Speaker Speaker Strobe Multi Candela Red SE Speaker Red SE Speaker White 500 636026 SE Speaker Speaker Strobe Multi Candela White 500 636027 SE Speaker Speaker Strobe Hi Multi Candela Red 500 636028 SE Speaker Speaker Strobe Hi Multi Candela White YES SE Speaker Ceiling Red SE Speaker Ceiling White 500 636031 500 636032 500 636034 500 636033 Speaker Speaker Strobe Ceiling Red Speaker Speaker Strobe Ceiling White Speaker Speaker Strobe Multi Candela Ceiling White Speaker Speaker Strobe Multi Candela Ceiling Red

Related Files