Siemens SE, SEC Notification Appliances (for Canada) Speaker and Speaker Strobes, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

s Sheet Safety Products Appliances Speaker and Speaker Strobes ULC Application Indoor Strobe Strobe Overview Strobe portion of Siemens Series appliances can be synchronized using the Siemens and 504 point addressable fire alarm control panels FACPs as well as with FireFinder XLS V FACPs PAD 4 NAC Extenders Siemens dual sync control DSC modules Ceiling mount models are available with field selectable Candela settings of 15 30 75 95cd Wall mount speaker strobe models with field selectable Candela settings of 15 30 75 110cd Mounts to 4 10.2 cm square 2 1 8 5.4 cm deep back box An Optional Extender SPEXT can be used for mounting ceiling only appliances to 4 10.2 cm backboxes No extension ring is required for Siemens Series appliances used in wall mount applications High efficiency design for maximum output at minimum across a frequency range of 562 to 4,470 Hz Field selectable taps for 25 or 70 VRMS operation from 1 8 Watt up to 2 Watts Fast installation with In Out screw terminals using 12 to 18 AWG wires Snap on grille cover with non visible mounting screws Complies with OSHA 29 Part 1910.16 Listed ULC Listed 3150 and CSFM Approved 7125 0067 0254 Fire Alarm Devices For The Hearing Impaired Speakers Canada Limited Technologies Division Series Notification Appliances 2580C Speaker appliances are Siemens Series Speakers and the speaker strobe appliances Siemens Series Speaker Strobes or approved equals Speakers are UL Listed under Standard 1480 for Fire Protective Service and speakers with strobes are listed under UL Standard 1971 for Emergency Devices the Hearing Impaired Speakers are ULC Listed under Standard S541 Speakers for Fire Alarm Systems Accessories and strobes are listed under S526 Visible Signal Devices Fire Alarm Systems Including Accessories Speaker portion is designed for a field selectable input of either 25 or 70 VRMS selectable power taps from 1 4 Watt to 2 Watts Speakers are comprised of a sealed back construction All inputs accept terminals that use 12 to 18 AWG wire sizes Strobe intensity where multi Candela appliances are specified have settings and are rated per ULC Standard S526 for wall mount ceiling mount Manual selector switch for setting the candela is tamper resistant The strobe portion when synchronization is required is compatible via the use of the Siemens and 504 point addressable fire alarm control panels FACPs as well as with FireFinder XLS V FACPs PAD 4 NAC Extenders Siemens dual sync control DSC modules The strobes do not drift out of synchronization at any time during operation The strobes will revert to a non synchronized flash rate if the sync module Power Supply should fail to operate i e contacts remain closed Wall mount speaker and speaker strobe appliances are designed for indoor flush to 4 10.2 cm square 2 1 8 5.4 cm electrical boxes without for an extension ring or surface mounting Ceiling mount speaker strobe Series appliances are designed for indoor flush mounting Speaker and speaker strobe incorporate a speaker mounting plate with a snap on grille cover finish on each grille for Siemens Series speakers and speaker strobes is white or red All speaker and speaker strobe appliances are listed for Special Applications are designed to flash at 1 flash per second minimum over their Input Voltage Range Notes NFPA 72 specifies a flash rate of 1 to 2 flashes per second Guidelines specify a flash rate of 1 to 3 flashes per second candela ratings represent minimum effective Strobe intensity based on UL Standard 1971 Canada Limited Technologies Division Diagram Strobe Mount Only Strobe Mount Only or Ceiling Mount In Inches Options Series Ceiling Mount Strobes Ratings AMPs Voltage 16.0 33.0VDC 16.0 33.0VRMS 0.117 RMS Current with Hi dBA Setting Series Wall Mount Strobes Ratings AMPs Voltage 16.0 33.0VDC 16.0 33.0VRMS RMS Current with Hi dBA Setting Data SEC Series Speakers Listed Models and Ratings dBA CAN ULC S541 All models available in red or white All models are ULC Listed for indoor use with a range of 32 to 120 0 to 49 maximum humidity of 85 RH is rated per ULC Standard for Speaker Appliances range of speakers is 562 4,470Hz SEC Series Speakers Voltage Wattage Connection Chart Canada Limited Technologies Division for Ordering Including Mounting Options Agency Approvals Agency Approvals ULC FM CSFM SE Speaker Red SE Speaker White 500 636026C 500 636031C 500 636032C Speaker Speaker Strobe Multi Candela Red Speaker Speaker Strobe White Speaker Ceiling Red Speaker Ceiling White Speaker Speaker Strobe Ceiling Red Speaker Speaker Strobe Ceiling White SPEXT is an extender ring that mounts behind the speaker to permit to a 4 10.2 cm square 2 1 8 5.4 cm deep box without the need for an extension ring on the box There are no restrictions mounting Siemens Speaker appliances to wall or ceiling listed approved Refer to data sheet 2585 for detailed options This marketing data sheet is not intended to be used for system design or installation purposes For the most up to date information refer to each product installation instructions Canada Limited Technologies Division Ltd Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA 2015 sheet dated 12 2009 2

Related Files