Siemens SET-CMC-R-MNS-ALERT SET-AMC-W-MNS-ALERT SET-CMC-CW-MNS-ALERT SET- Mass Notification Speaker-Strobes Appliances, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

s Sheet Safety Products Appliances Mass Notification Speaker Strobes Appliances Applications Indoor Outdoor Speaker Strobe cid 326 Speaker Strobe cid 326 Mount Speaker Strobe cid 326 Mount Mount Red Overview The Model SET series of speaker strobes is optionally compatible with a non synchronized appliance when connected directly to a UL2572 Listed mass notification system or can with a synchronized strobe appliance when connected to a notification appliance running the Siemens sync protocol SET series of speaker strobes are UL Listed for use with UL2572 Listed mass notification systems SET series speaker strobes are designed for multiple power requirements with high dBA at each power tap The design incorporates a high efficiency speaker for maximum output at minimum power a frequency range of 400Hz to 4000Hz and features a sealed back construction for protection and improved audibility Speaker strobes offer a choice of field selectable taps for 25 or 70 VRMS operation 1 8 Watt to 8 Watts Available with a CLEAR lens or AMBER lens option Ceiling models are available with field selectable CLEAR lens Candela settings of 15 30 75 95cd Wall mount models are available with field selectable CLEAR lens Candela settings of 15 30 75 110cd Ceiling models are available with field selectable AMBER lens Candela settings of 11 22 56 71cd Wall mount models are available with field selectable AMBER lens Candela settings of 11 22 56 82cd Strobes can be synchronized using the Siemens DSC sync controls XLSM panel PAD series power supplies with built in sync protocol Only available with text on the outside of each device A speaker mounting plate is attached to the speaker for easier installation Complies with Occupational Safety and Health Administration OSHA 29 Part 1910.165 With Disabilities Act ADA and National Fire Protection Agency NFPA 72 Meets the requirements of the new NFPA 72 Chapter 24 v2010 requirements for applications of notification appliances for MNS Series Notification Appliances 2587 Industry Inc Technologies Division Speaker strobe appliances shall be Siemens Series SET Speaker Strobes or approved equals be used with UL 2572 Listed mass notification systems Speakers equipped with strobes shall be listed under UL Standard 1971 for Emergency Devices All models shall have listed sound output of up to 93dB at 10 feet and a listed frequency the hearing impaired of 400 to 4000 Hz Speakers shall be designed for a field selectable input of either 25 or 70 VRMS with power taps from 1 8 Watt to 8 Watts Speaker shall incorporate a sealed back construction All inputs shall employ terminals that accept 12 to 18 American Wire Gauge AWG wire sizes Strobe portion of the appliance shall produce a flash rate of one 1 flash per second shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens Strobe shall be of low current design Selector switch for selecting the candela shall be tamper resistant Strobes can be synchronized using the Siemens DSC sync controls and are utilized as 2572 Listed mass notification devices XLSM panel PAD series power supplies with built in sync protocol The strobes shall not drift out of synchronization at any time during operation Strobes are available in AMBER and CLEAR lens and devices for mass notification will have word appear on its cover in red text Strobes shall revert to a non synchronized flash rate if the sync module or power supply fail to operate i e contacts remain closed Speaker strobe appliances shall be designed for indoor outdoor surfaces Speaker strobe shall incorporate a speaker mounting plate with a grille cover is secured with two 2 screws for a level finish Grille cover shall mount to standard electrical hardware requiring no additional plate or adapter All speaker strobe appliances shall be listed for Special Applications are designed to flash at 1 flash per second minimum over their Input Voltage Range Note NFPA 72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify flash rate of 1 to 3 flashes per second Standard 1971 candela ratings represent minimum effective Strobe intensity based on Industry Inc Technologies Division Diagram Diagram In Inches Options Industry Inc Technologies Division Back box is compatible with holes are double gang 3 1 2 and octagon or Data Notes 1 Models are UL Listed for indoor outdoor use with a temperature range of 32 to 120 0 to 49 and maximum humidity of 93 non condensing The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is in the original cartons and is not subjected to misuse or abuse The maximum supervision voltage is 33 Volts DC Frequency range of speakers is 400 400Hz CAUTION Always operate audio amplifiers and speakers within their specified ratings Excessive input may distort sound quality and may damage equipment Do not exceed 100 of speaker input voltage per UL 1480 Improper input voltage can damage speaker If distortion is check for clipping of the audio appliance with an oscilloscope and reduce the amplifier input level or gain level to eliminate any Candela setting will determine the current draw of the product Candela is measured on axis Multi Candela settings have been derated approximately 25 for Amber lens for Ordering Amber Speaker Strobe multi Candela Wall Mount White cid 367 Amber Speaker Strobe multi Candela Ceiling Mount White cid 367 Amber Speaker Strobe multi Candela Wall Mount Red cid 3 cid 367 Amber Speaker Strobe multi Candela Ceiling Mount Red cid 3 cid 367 Clear Speaker Strobe multi Candela Wall Mount White cid 367 Clear Speaker Strobe multi Candela Ceiling Mount White cid 367 Clear Speaker Strobe multi Candela Wall Mount Red cid 3 cid 367 Clear Speaker Strobe multi Candela Ceiling Mount Red cid 3 cid 367 This marketing data sheet is not intended to be used for system design or installation purposes the most up to date information refer to each product installation instructions Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www usa Siemens com Fire Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA in U S A 2014 sheet dated 8 2011 2

Related Files