Siemens Siemens ASD

File Preview
File Preview
Click below to download for free

File Data

Name siemens-siemens-asd-4769253810.pdf
Type PDF
Size 3.20 MB
Downloads

Text Preview

Sinteso Cerberus PRO Aspirating smoke detector FDA221 aspirating smoke detector ASD for the addressed FDnet C NET de line or for standalone operation Patented technology Early detection of a wider spectrum of particle sizes in the air Configuration using the USB interface or the control panel via FDCC221S op ASD Asyst Tool software to assist with pipe configuration Unique dust resistant detection chamber Intuitive front indicator for airflow and smoke value Access to service functions Different event protocols Offline online configuration supported Cleaning function FDA241 4 output Infrastructure Extended optical detection thanks to dual wavelengths blue and infrared The aspirat smoke detectors FDA241 and FDA221 use dual wavelength technology to trigger an at the earliest possible moment They are designed to protect small and medium business critical environments for monitoring areas of up to 800 FDA241 or FDA221 The detectors continually suck in air through a pipe system via their holes The air is fed into a uniquely designed detection chamber in which tiny particles are detected by scattered light Lower mounting and service costs The aspirating smoke detectors FDA241 and can be used on an FDnet C NET detector line For this purpose communication FDCC221S is required Configuration using the USB interface or the control panel via FDCC221S optional All configurations maintenance work and alarm and fault management processes be carried out at a central location the fire control panel This ensures better con while also reducing the costs of the overall solution Out of the box mounting and commissioning Installation is simple thanks to combined for normalizing smoke values and airflow as well as appropriate presettings for and fault thresholds ASD filter box FDAZ292 available as an accessory Dust and other dirt is filtered out of aspirated air and does not get into the aspirating smoke detector The filters in the filter box are easy to replace smoke detectors are used for early detection of smoke generating fires in rooms equipment They are especially suited to applications in which point detectors are to their limits cannot be used or can only be used with restrictions aspirating smoke detector continually takes air from the monitored room using a connec pipe system with defined aspirating holes The air is supplied to the detection chamber is analyzed for smoke particles using the detector installed there The sensitivity of the can be adjusted position and size of the aspirating holes is calculated using the FXS2056 software The calculation ensures that the air passes from the aspirating hole to the in the time specified and with the required calculated sensitivity FXS2056 Tool software replaces the FXS2055 Asyst Tool soft of application Cavities such as false ceilings or false floors Clean rooms Rooms the height of which is greater than that permitted for point detectors Rooms with electromagnetic fields which influence the function of point detectors Large rooms up to 800 Separate monitoring of control cabinets and electronics cabinets Data centers Telecommunication centers Mounting lines Cable tunnels Conveyor belts with a filter box Rooms with polluted air in which the pollution has impaired the performance of optical detectors Mounting lines Recycling facilities Cement factories Infrastructure Mining industry Subway stations Agricultural operations All other applications with visible dust load display contains clear comprehensible bar graphs for smoke and airflow as well as an indicator an error indicator and a dust indicator FDA241 the housing cover is open the operator has access to the Reset Normalize Smoke Normalize Flow functions as well as the mini USB connector Front indicator Front indicator for the response indicators warnings alarm alarm Infrastructure flow flow flow 2 1 smoke the detector to the connection cable order to prevent damage to the connection cable when positioning the housing cover sure that the connection cable has been routed correctly service area for the detector can be accessed in two ways Partial access Remove the two screws on the top of the detector Slide the housing cover up until you hear it snap into place Full access Remove the two screws on the top of the detector Slide the housing cover up until you hear it snap into place Pull the housing cover out slightly at the sides and lift it up Remove the housing cover Infrastructure LED indicators and buttons OK soon as the selftest for normal operation has been completed successfully the Flow starts to flash OK soon as the selftest for normal operation has been completed successfully the LED starts to flash the event of a smoke alarm the Alarm LED starts to flash of the airflow determine the nominal airflow of the detector perform this function during commissioning nominal value established during normalization of the airflow forms the setpoint value for the airflow during normal operation perform this function use a thin object such as a paper clip or a watchmaker s screw to press the button in the opening you have finished with this function press the button in the opening again smoke detector uses standard values for monitoring during normalization of the smoke density determine the nominal air quality in relation to the smoke density perform this function commissioning The nominal value established during normalization forms the set value for monitoring the smoke density during normal operation perform this function use a thin object such as a paper clip or a watchmaker s screw to press the button in the opening you have finished with this function press the button in the opening again smoke detector uses standard values for monitoring during normalization detector provides information about the current normalization process via FDnet C no distinction is made between smoke and airflow button the reset button to reset all of the detector s status indicators These indicators can refer fire alarms or airflow events Resetting the fire alarm also resets the associated relay the detector is operated on the FDnet C NET the alarms and the associated relays are reset connection can use a mini USB cable to connect the detector to a Windows PC To set up the de use the configuration tool FXS2051 Configuration Tool function LED the Buzzer silence button down for 5 The LEDs on the display are tested 3 different brightness settings Infrastructure the aspirating smoke detector is to be operated on the FDnet C NET the communication FDCC221S S24218 A201 A2 must be ordered separately interface supply kit For connecting the aspirating smoke detector to FDnet C NET Integrated line separator function Additional MC link interface port for 3.5 mm jack Tool free mounting on a designated PCB slot Supplied with 2x with thread 4 pin plug in terminal ID adhesive label Standalone power supply Supply to external devices and components as per EN and VdS With operating and fault indicator shown via a green and a yellow LED With potential free relay contacts for fault messages Additional installation of an I O module possible Uninterruptible power supply with battery charging Batteries max Dimensions W 430 12 7 VdS For su

Related Files