Siemens SIM-16 Desigo Modular Supervised Input Module, Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

Fire Safety system Input Module SIM 16 Architect Engineer Specifications Provides 16 general purpose for remote sub systems Each input separately for supervision or supervision Provides two 2 Form C relays Input circuits are power limited Mounts remotely from fire alarm panel FACP Programmable input circuit usage Trouble Supervisory Status UL864 CAN ULC S576 Listed CSFM NYC Fire Department Product Overview Supervised Input Module Model SIM 16 is a remotely located general input module that provides 16 input circuits for remote system monitoring input can be individually programmed as super vised dry contact only or general purpose input Model SIM 16 has two 2 Form C relays relays and inputs are programmed using the Zeus D custom configuration tool Specifications SIM 16 is mounted in an enclosure that is remotely located from the main Fire Safety Modular FACP Communication between Model SIM 16 and the Interface Card Model NIC C is through the Control Area Network CAN Up to 99 Model SIM 16 modules can be used with a single Model NIC C card Model SIM 16 has two 2 10 position rotary switches that used to set the board address on the CAN which is a sub of Model NIC C each Model SIM 16 supervised input circuit can at a maximum length of 500 feet 152.4 meters time a change of state of the input is detected a unique message is sent to Model NIC C A CAN message from NIC C directed to Model SIM 16 controls the Form C SIM 16 may be installed in a Model REMBOX2 or Model or in other UL 864 Listed enclosure If using Model or Model REMBOX4 mount Model SIM 16 in one 1 space on a Model REMBOX2 MP or Model REMBOX4 MP the four 4 screws provided to four 4 Model SIM 16 modules will fit in a REMBOX2 and to eight 8 Model SIM 16 modules will fit in a given Each Model SIM 16 input module fits into a single 3TM module footprint SIM 16 Input Infrastructure Building Products Sheet 7319 Temperature and Humidity Range are UL 864 9th Edition Listed for indoor dry locations within a temperature range of 120 3 49 2 to 32 0 2 and a relative humidity of 93 2 at a temperature of 90 3 32 2 for Ordering TYPE CABLE 3ft 0.9m Required Input Module EMBOX2 Lobby Enclosure EMBOX4 Lobby Enclosure Ratings CURRENT DRAW Plane CURRENT DRAW Terminal 1.2mA Supervised 20mA Active relay CURRENT DRAW Plane CURRENT DRAW 10mA per 1.2mA Input 20mA relay POWER peak to peak max max message transmission PAIR NOTICE The information contained in this data sheet document is intended only a summary and is subject to change without notice product s described here has have a specific instruction sheet s cover various technical limitation and liability information of install type instruction sheets as well as the General Product and Limitations document which also contains important data provided with the product and are available from the Manufacturer contained in the aforesaid type of documentation should be consulted a fire safety professional before specifying or using the product Any further questions or assistance concerning problems that might arise relative to the functioning of the equipment please contact Manufacturer Fire Safety Industry Inc Technologies Division Fernwood Road Florham Park NJ 07932 973 593 2600 2020 1

Related Files